Automatic removal of the eye blink artifact from EEG using an ICA-based template matching approach
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Independent component analysis (ICA) proves to be effective in the removing the ocular artifact from electroencephalogram recordings (EEG). While using ICA in ocular artifact correction, a crucial step is to correctly identify the artifact components among the decomposed independent components. In most previous works, this step of selecting the artifact components was manually implemented, which is time consuming and inconvenient when dealing with a large amount of EEG data. We present a new method which automatically selects the eye blink artifact components based on the pattern of their scalp topographies, which can be exemplified as a template matching approach. The feasibility of using a fixed template for singling out the eye blink component after ICA decomposition was validated by an experiment in which 18 subjects among the 21 subjects involved exhibited a highly consistent pattern of eye blink scalp topographies. Since only the spatial feature is employed for singling out the eye blink component, the proposed method is very efficient and easy to implement. Objective evaluation of the real results shows that the proposed algorithm can remove the eye blink artifact from the EEG while causing little distortion to the underlying brain activities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“In this paper, we employ the extended infomax ICA algorithm (Bell and Sejnowski 1995, Lee et al 1999).”
MethodA new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055 · cited 1×
“Among them the most popular approach is the regression-based method (Gratton et al 1983, Croft and Barry 2000a, 2000b), either in the time domain or in the frequency domain.”
MethodRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Lee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 1×
“In this paper, we employ the extended infomax ICA algorithm (Bell and Sejnowski 1995, Lee et al 1999).”
MethodJung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322 · cited 5×
“These scalp weights give the scalp topography of each component, and provide evidence for the components’ physiological origin (Jung et al 2000a).”
BackgroundMethodInfluentialRemoval of ocular artifact from the EEG: a review
Croft, R. J., & Barry, R. J. (2000) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/s0987-7053(00)00055-1 · Cited by 756 · cited 1×
“Among them the most popular approach is the regression-based method (Gratton et al 1983, Croft and Barry 2000a, 2000b), either in the time domain or in the frequency domain.”
MethodAutomatic removal of eye movement and blink artifacts from EEG data using blind component separation
Joyce, C. A., Gorodnitsky, I. F., & Kutas, M. (2004) · Psychophysiology · doi:10.1111/j.1469-8986.2003.00141.x · Cited by 596 · cited 3×
“The limitation of the PCA-based ocular OA removal method is that PCA assumes that the decomposed components are algebraically orthogonal, which is in general difficult to satisfy (Joyce et al 2004).”
MethodOcular artifacts in EEG and event-related potentials I: Scalp topography
Lins, O. G., Picton, T. W., Berg, P., & Scherg, M. (1993) · Brain Topography · doi:10.1007/bf01234127 · Cited by 323 · cited 2×
“Another class of the OA removal method is the component-based method, including the principal component analysis (PCA) based method (Lins et al 1993) and the ICA-based method (Jung et al 1998, 2000a, 2000b, Joyce et al 2004, Makeig et al 1996).”
MethodRemoving electroencephalographic artifacts: comparison between ICA and PCA
Jung, T.-P., Humphries, C., Lee, T.-W., Makeig, S., McKeown, M. J., Iragui, V., & Sejnowski, T. J. (2002) · Neural Networks for Signal Processing VIII. Proceedings of the 1998 IEEE Signal Processing Society Workshop (Cat. No.98TH8378) · doi:10.1109/nnsp.1998.710633 · Cited by 191 · cited 1×
“Another class of the OA removal method is the component-based method, including the principal component analysis (PCA) based method (Lins et al 1993) and the ICA-based method (Jung et al 1998, 2000a, 2000b, Joyce et al 2004, Makeig et al 1996).”
MethodArtifact removal from electroencephalograms using a hybrid BSS-SVM algorithm
Shoker, L., Sanei, S., & Chambers, J. (2005) · IEEE Signal Processing Letters · doi:10.1109/lsp.2005.855539 · Cited by 160 · cited 2×
“Support vector machines (SVM) have been introduced into eye blink artifact removal (Shoker et al 2005).”
MethodEOG correction: Which regression should we use?
Croft, R. J., & Barry, R. J. (2000) · Psychophysiology · doi:10.1111/1469-8986.3710123 · Cited by 53
Cited by
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
FASTER: Fully Automated Statistical Thresholding for EEG artifact Rejection
Nolan, H., Whelan, R., & Reilly, R. B. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.015 · Cited by 1,077
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Coregistration of eye movements and EEG in natural reading: Analyses and review.
Dimigen, O., Sommer, W., Hohlfeld, A., Jacobs, A. M., & Kliegl, R. (2011) · Journal of Experimental Psychology: General · doi:10.1037/a0023885 · Cited by 602
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Metadata
- Authors
- Li, Y., Ma, Z., Lu, W., & Li, Y.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2006-03-14
- Volume
- 27
- Issue
- 4
- Pages
- 425-436
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2009782817
- Cited by
- 197
- References
- 12
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.