The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Novel dry electrodes for ECG monitoring
Open accessAbstract
The development, fabrication and characterization of two novel dry bioelectrodes--conductive and capacitive ones--for biopotential monitoring are presented. The new electrodes have the potential to improve the applicability of dry electrodes in ambulant recording of ECG by reducing motion artifacts as well as the contact impedance to the skin. Furthermore, a passive filter network is integrated into the new electrodes to suppress slow offset fluctuation of the ECG signal caused e.g. by motions like breathing or changes in the electrode-skin interface properties. Compared to standard gel electrodes these new electrodes exhibit equivalent and superior contact impedances and biosignals. The integrated filter network effectively suppresses fluctuating offset potentials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“as the gel dries during extended use the electrode contact impedance rises sharply which makes the signal susceptible to external noise. [37]”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [37]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90338-v · Cited by 7,153
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,846
Medical instrumentation: Application and design
Undar, A., Calhoon, J., & da Rocha, A. (1997) · Control Engineering Practice · doi:10.1016/s0967-0661(97)90030-7 · Cited by 1,019
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 736
Micromachined electrodes for biopotential measurements
Griss, P., Enoksson, P., Tolvanen-Laakso, H., Meriläinen, P., Ollmar, S., & Stemme, G. (2001) · Journal of Microelectromechanical Systems · doi:10.1109/84.911086 · Cited by 240
A dry electrode for EEG recording
Taheri, B. A., Knight, R. T., & Smith, R. L. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90053-1 · Cited by 177
Temporal changes in electrode impedance while recording the electrocardiogram with “Dry” electrodes
Geddes, L. A., & Valentinuzzi, M. E. (1973) · Annals of Biomedical Engineering · doi:10.1007/bf02407675 · Cited by 98
Optimum electrolytic chloriding of silver electrodes
Geddes, L. A., Baker, L. E., & Moore, A. G. (1969) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474669 · Cited by 85
Mobile patient monitoring based on impedance-loaded SAW-sensors
Karilainen, A. O., Finnberg, T., Uelzen, T., Dembowski, K., & Müller, J. W. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1367487 · Cited by 30
Self-citationMayer-Gindner, A., Lek-Uthai, A., Abdallah, O., & Bolz, A. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.024 · Cited by 18
Cited by
Sorted by citations
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,069
Nanomaterial‐Enabled Stretchable Conductors: Strategies, Materials and Devices
Yao, S., & Zhu, Y. (2015) · Advanced Materials · doi:10.1002/adma.201404446 · Cited by 702
Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C., Liao, L., Liu, Y., Wang, I.-J., Lin, B., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336
Cognition in action: imaging brain/body dynamics in mobile humans
Gramann, K., Gwin, J. T., Ferris, D. P., Oie, K. S., Jung, T., Lin, C., Liao, L., & Makeig, S. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.047 · Cited by 307
Dry electrodes for electrocardiography
Meziane, N., Webster, J. G., Attari, M., & Nimunkar, A. J. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/9/r47 · Cited by 289
Metadata
- Authors
- Gruetzmann, A., Hansen, S., & Müller, J.
- Affiliations
- Hamburg University of Technology (DE)
- ORCID
- Müller, Jörg
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2007-10-12
- Volume
- 28
- Issue
- 11
- Pages
- 1375-1390
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2138886665
- Cited by
- 248
- References
- 12
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 15 · 2023: 21 · 2022: 11 · 2021: 15 · 2020: 19 · 2019: 25 · 2018: 21 · 2017: 9 · 2016: 22 · 2015: 18 · 2014: 15 · 2013: 17 · 2012: 10
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- dry electrodes, ECG monitoring, conductive electrodes, capacitive electrodes, motion artifacts, contact impedance, skin-electrode interface, biopotential monitoring
- MeSH terms
- Elasticity, Electrodes, Equipment Design, Evoked Potentials, Humans, Electrocardiography, Ambulatory, Artifacts, Electric Impedance, Equipment Failure Analysis, Electric Capacitance, Cardiac Electrophysiology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review