The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Novel dry electrodes for ECG monitoring
Open accessAbstract
The development, fabrication and characterization of two novel dry bioelectrodes--conductive and capacitive ones--for biopotential monitoring are presented. The new electrodes have the potential to improve the applicability of dry electrodes in ambulant recording of ECG by reducing motion artifacts as well as the contact impedance to the skin. Furthermore, a passive filter network is integrated into the new electrodes to suppress slow offset fluctuation of the ECG signal caused e.g. by motions like breathing or changes in the electrode-skin interface properties. Compared to standard gel electrodes these new electrodes exhibit equivalent and superior contact impedances and biosignals. The integrated filter network effectively suppresses fluctuating offset potentials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“as the gel dries during extended use the electrode contact impedance rises sharply which makes the signal susceptible to external noise. [37]”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [37]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90338-v · Cited by 7,153
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,846
Medical instrumentation: Application and design
Undar, A., Calhoon, J., & da Rocha, A. (1997) · Control Engineering Practice · doi:10.1016/s0967-0661(97)90030-7 · Cited by 1,019
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 736
Micromachined electrodes for biopotential measurements
Griss, P., Enoksson, P., Tolvanen-Laakso, H., Meriläinen, P., Ollmar, S., & Stemme, G. (2001) · Journal of Microelectromechanical Systems · doi:10.1109/84.911086 · Cited by 240
A dry electrode for EEG recording
Taheri, B. A., Knight, R. T., & Smith, R. L. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90053-1 · Cited by 177
Temporal changes in electrode impedance while recording the electrocardiogram with “Dry” electrodes
Geddes, L. A., & Valentinuzzi, M. E. (1973) · Annals of Biomedical Engineering · doi:10.1007/bf02407675 · Cited by 98
Optimum electrolytic chloriding of silver electrodes
Geddes, L. A., Baker, L. E., & Moore, A. G. (1969) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474669 · Cited by 85
Mobile patient monitoring based on impedance-loaded SAW-sensors
Karilainen, A. O., Finnberg, T., Uelzen, T., Dembowski, K., & Müller, J. W. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1367487 · Cited by 30
Self-citationMayer-Gindner, A., Lek-Uthai, A., Abdallah, O., & Bolz, A. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.024 · Cited by 18
Cited by
Sorted by citations
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,069
Nanomaterial‐Enabled Stretchable Conductors: Strategies, Materials and Devices
Yao, S., & Zhu, Y. (2015) · Advanced Materials · doi:10.1002/adma.201404446 · Cited by 702
Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C., Liao, L., Liu, Y., Wang, I.-J., Lin, B., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336
Cognition in action: imaging brain/body dynamics in mobile humans
Gramann, K., Gwin, J. T., Ferris, D. P., Oie, K. S., Jung, T., Lin, C., Liao, L., & Makeig, S. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.047 · Cited by 307
Dry electrodes for electrocardiography
Meziane, N., Webster, J. G., Attari, M., & Nimunkar, A. J. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/9/r47 · Cited by 289
Wearable silver nanowire dry electrodes for electrophysiological sensing
Myers, A. C., Huang, H., & Zhu, Y. (2015) · RSC Advances · doi:10.1039/c4ra15101a · Cited by 231
Lee, S. M., Byeon, H. J., Lee, J. H., Baek, D. H., Lee, K. H., Hong, J. S., & Lee, S.-H. (2014) · Scientific Reports · doi:10.1038/srep06074 · Cited by 181
Liao, L., Wang, I.-J., Chen, S.-F., Chang, J., & Lin, C. (2011) · Sensors · doi:10.3390/s110605819 · Cited by 181
Ambient and Unobtrusive Cardiorespiratory Monitoring Techniques
Brüser, C., Antink, C. H., Wartzek, T., Walter, M., & Leonhardt, S. K. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2414661 · Cited by 175
Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review
Sun, Y., & Yu, X. B. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2519392 · Cited by 174
An Adaptive Kalman Filter for ECG Signal Enhancement
Vullings, R., de Vries, B., & Bergmans, J. W. M. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2099229 · Cited by 174
Textile-structured electrodes for electrocardiogram
Xu, P., Zhang, H., & Tao, X. (2008) · Textile Progress · doi:10.1080/00405160802597479 · Cited by 171
Biosensor Technologies for Augmented Brain–Computer Interfaces in the Next Decades
Liao, L., Lin, C., McDowell, K., Wickenden, A. E., Gramann, K., Jung, T., Ko, L., & Chang, J. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2184829 · Cited by 170
Noncontact Wearable Wireless ECG Systems for Long-Term Monitoring
Majumder, S., Chen, L. L., Marinov, O., Chen, C., Mondal, T. K., & Deen, M. J. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2840336 · Cited by 166
Lanatà, A., Valenza, G., Nardelli, M., Gentili, C., & Scilingo, E. P. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2360711 · Cited by 168
Nanomaterial-Enabled Dry Electrodes for Electrophysiological Sensing: A Review
Yao, S., & Zhu, Y. (2016) · JOM · doi:10.1007/s11837-016-1818-0 · Cited by 172
Screen-Printed PEDOT:PSS Electrodes on Commercial Finished Textiles for Electrocardiography
Sinha, S., Noh, Y., Reljin, N., Treich, G. M., Hajeb-Mohammadalipour, S., Guo, Y., Chon, K. H., & Sotzing, G. A. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b09954 · Cited by 161
Bollella, P., Sharma, S., Cass, A. E. G., & Antiochia, R. (2019) · Electroanalysis · doi:10.1002/elan.201800630 · Cited by 153
Ismail, L. E., & Karwowski, W. (2020) · PLoS ONE · doi:10.1371/journal.pone.0242857 · Cited by 167
Textile Electrodes for EEG Recording — A Pilot Study
Löfhede, J., Seoane, F., & Thordstein, M. (2012) · Sensors · doi:10.3390/s121216907 · Cited by 145
Wearable sensors for ECG measurement: a review
Sudha, R., & Balan, A. (2018) · Sensor Review · doi:10.1108/sr-06-2017-0110 · Cited by 136
PDMS-Based Low Cost Flexible Dry Electrode for Long-Term EEG Measurement
Wang, L., Liu, J., Yang, B. T., & Yang, C. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2204339 · Cited by 119
Fully Printed Electrodes on Stretchable Textiles for Long‐Term Electrophysiology
Bihar, E., Roberts, T., Ismailova, E., Saadaoui, M., Işık, M., Sanchez‐Sanchez, A., Mecerreyes, D., Hervé, T., Graaf, J. B. D., & Malliaras, G. G. (2017) · Advanced Materials Technologies · doi:10.1002/admt.201600251 · Cited by 114
Novel Electrodes for Underwater ECG Monitoring
Reyes, B. A., Posada-Quintero, H. F., Bales, J. R., Clement, A. L., Pins, G. D., Swiston, A. J., Riistama, J. M., Florian, J. P., Shykoff, B. E., Qin, M. K., et al. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309293 · Cited by 114
Vidhya, C. M., Maithani, Y., & Singh, J. P. (2023) · Biosensors · doi:10.3390/bios13070679 · Cited by 113
Development of a quasi-dry electrode for EEG recording
Mota, A., Duarte, L., Rodrigues, D., Martins, A. C., Machado, A. V., Vaz, F., Fiedler, P., Haueisen, J., Nóbrega, J. M., & Fonseca, C. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.06.013 · Cited by 111
Unobtrusive sleep state measurements in preterm infants – A review
Werth, J., Atallah, L., Andriessen, P., Long, X., Zwartkruis-Pelgrim, E., & Aarts, R. M. (2016) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2016.03.005 · Cited by 106
Gharibans, A. A., Smarr, B. L., Kunkel, D. C., Kriegsfeld, L. J., Mousa, H. M., & Coleman, T. P. (2018) · Scientific Reports · doi:10.1038/s41598-018-23302-9 · Cited by 100
Surface bioelectric dry Electrodes: A review
Niu, X., Gao, X., Liu, Y., & Liu, H. (2021) · Measurement · doi:10.1016/j.measurement.2021.109774 · Cited by 100
Cosoli, G., Spinsante, S., Scardulla, F., D’Acquisto, L., & Scalise, L. (2021) · Measurement · doi:10.1016/j.measurement.2021.109243 · Cited by 102
Xu, X., Luo, M., He, P., & Yang, J. (2019) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab5f4a · Cited by 91
Xu, X., Liu, Z., He, P., & Yang, J. (2019) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab3869 · Cited by 82
Paul, G., Torah, R. N., Beeby, S., & Tudor, J. (2014) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2014.10.030 · Cited by 82
A multichannel portable ECG system with capacitive sensors
Oehler, M., Ling, V., Melhorn, K., & Schilling, M. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/7/007 · Cited by 82
Parylene-based flexible dry electrode for bioptential recording
Peng, H. L., Liu, J. Q., Dong, Y.-Z., Yang, B. T., Chen, X. '., & Yang, C. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.02.061 · Cited by 82
Heart Monitor Using Flexible Capacitive ECG Electrodes
Gao, Y., Soman, V. V., Lombardi, J. P., Rajbhandari, P. P., Dhakal, T. P., Wilson, D. G., Poliks, M. D., Ghose, K., Turner, J. N., & Jin, Z. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2949320 · Cited by 78
An Overview of the Sensors for Heart Rate Monitoring Used in Extramural Applications
Galli, A., Montree, R. J. H., Que, S., Peri, E., & Vullings, R. (2022) · Sensors · doi:10.3390/s22114035 · Cited by 87
Daily Electrode Change and Effect on Cardiac Monitor Alarms: An Evidence-Based Practice Approach
Cvach, M. M., Biggs, M., Rothwell, K. J., & Charles-Hudson, C. (2013) · Journal of Nursing Care Quality · doi:10.1097/ncq.0b013e31827993bc · Cited by 75
Screen printed graphene electrodes on textile for wearable electrocardiogram monitoring
Xu, X., Luo, M., He, P., Guo, X., & Yang, J. (2019) · Applied Physics A · doi:10.1007/s00339-019-3006-x · Cited by 75
Dry electrodes for bioimpedance measurements—design, characterization and comparison
Kusche, R., Kaufmann, S., & Ryschka, M. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aaea59 · Cited by 72
A novel passive electrode based on porous Ti for EEG recording
Peng, H., Liu, J., Tian, H., Dong, Y.-Z., Yang, B. T., Chen, X., & Yang, C. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.11.141 · Cited by 70
Skin-Mountable Biosensors and Therapeutics: A Review
Lee, E. K., Kim, M. K., & Lee, C. H. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052315 · Cited by 71
Inexpensive and flexible nanographene-based electrodes for ubiquitous electrocardiogram monitoring
Romero, F. J., Castillo, E., Rivadeneyra, A., Toral-López, A., Becherer, M., Ruiz, F. G., Rodríguez, N., & Morales, D. P. (2019) · npj Flexible Electronics · doi:10.1038/s41528-019-0056-2 · Cited by 71
Agostinelli, A., Grillo, M., Biagini, A., Giuliani, C., Burattini, L., Fioretti, S., Nardo, F. D., Giannubilo, S. R., Ciavattini, A., & Burattini, L. (2015) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12259 · Cited by 72
Combining Bioimpedance and EMG Measurements for Reliable Muscle Contraction Detection
Kusche, R., & Ryschka, M. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2936171 · Cited by 68
Joutsen, A. S., Cömert, A., Kaappa, E. S., Vanhatalo, K., Riistama, J. M., Vehkaoja, A. T., & Eskola, H. J. (2024) · Scientific Reports · doi:10.1038/s41598-024-56595-0 · Cited by 76
Chen, C.-Y., Chang, C., Chang, C., Lai, S.-C., Chien, T., Huang, H.-Y., Chiou, J., & Luo, C. (2013) · Sensors · doi:10.3390/s130303077 · Cited by 61
Piervirgili, G., Petracca, F., & Merletti, R. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/10/2101 · Cited by 61
Fabrication and impedance measurement of novel metal dry bioelectrode
Zhou, W., Song, R., Pan, X., Peng, Y., Qi, X., Peng, J., Hui, K. S., & Hui, K. S. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.06.025 · Cited by 61
Cömert, A., & Hyttinen, J. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0044-2 · Cited by 59
Multimodal Smart Eyewear for Longitudinal Eye Movement Tracking
Homayounfar, S. Z., Rostaminia, S., Kiaghadi, A., Chen, X., Alexander, E. T., Ganesan, D., & Andrew, T. L. (2020) · Matter · doi:10.1016/j.matt.2020.07.030 · Cited by 58
Assessment of Dry Epidermal Electrodes for Long-Term Electromyography Measurements
Yamagami, M., Peters, K. M., Milovanovic, I. P., Kuang, I., Yang, Z., Lu, N., & Steele, K. M. (2018) · Sensors · doi:10.3390/s18041269 · Cited by 61
Rathore, A. S., Li, Z., Zhu, W., Jin, Z., & Xu, W. (2020) · ACM Computing Surveys · doi:10.1145/3410158 · Cited by 62
Novel Noncontact Dry Electrode With Adaptive Mechanical Design for Measuring EEG in a Hairy Site
Chen, Y., Lin, B., & Pan, J. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2459531 · Cited by 56
Fully printed all-polymer tattoo/textile electronics for electromyography
Bihar, E., Roberts, T., Zhang, Y., Ismailova, E., Hervé, T., Malliaras, G. G., Graaf, J. B. D., Inal, S., & Saadaoui, M. (2018) · Flexible and Printed Electronics · doi:10.1088/2058-8585/aadb56 · Cited by 60
Conductive Polymer Foam Surface Improves the Performance of a Capacitive EEG Electrode
Baek, H. J., Lee, H. J., Lim, Y. G., & Park, K. S. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2215032 · Cited by 54
Rajanna, R. R., Sriraam, N., Vittal, P. R., & Arun, U. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2946058 · Cited by 56
Flexible PDMS electrode for one-point wearable wireless bio-potential acquisition
Chen, C.-Y., Chang, C.-L., Chien, T., & Luo, C. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.08.010 · Cited by 53
Yan, L., Yoo, J., Kim, B., & Yoo, H. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2065831 · Cited by 52
Tang, C. G., Wu, R., Chen, Y., Zhou, Z., He, Q., Li, T., Wu, X., Hou, K., Kousseff, C. J., McCulloch, I. A., et al. (2024) · Advanced Materials · doi:10.1002/adma.202405556 · Cited by 49
Properties of Dry and Non-contact Electrodes for Wearable Physiological Sensors
Gandhi, N., Khe, C., Chung, D., Yu, M., & Cauwenberghs, G. (2011) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2011.39 · Cited by 49
Le, K., Narayana, H., Servati, A., Bahi, A., Soltanian, S., Servati, P., & Ko, F. (2022) · Textile Research Journal · doi:10.1177/00405175221108208 · Cited by 48
Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes
O’Mahony, C., Grygoryev, K., Ciarlone, A., Giannoni, G., Kenthao, A., & Galvin, P. (2016) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/26/8/084005 · Cited by 47
Nanocomposite Ag:TiN thin films for dry biopotential electrodes
Pedrosa, P., Machado, D., Lopes, C., Alves, E., Barradas, N. P., Martin, N., Macedo, F., Fonseca, C., & Vaz, F. (2013) · Applied Surface Science · doi:10.1016/j.apsusc.2013.07.154 · Cited by 45
Assessment of Carbon/Salt/Adhesive Electrodes for Surface Electromyography Measurements
Posada-Quintero, H. F., Rood, R., Burnham, K., Pennace, J., & Chon, K. H. (2016) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2016.2567420 · Cited by 42
Dai, M., Xiao, X., Chen, X., Lin, H., Wu, W., & Chen, S. (2016) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-016-0483-5 · Cited by 42
Flexible and water-stable graphene-based electrodes for long-term use in bioelectronics
Murastov, G. V., Bogatova, E., Brazovskiy, K., Amin, I., Lipovka, A. A., Dogadina, E., Cherepnyov, A., Ananyeva, A., Plotnikov, E. V., Ryabov, V. V., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112426 · Cited by 42
Bhattacharya, S., Nikbakht, M., Alden, A., Tan, P., Wang, J., Alhalimi, T. A., Kim, S., Wang, P., Tanaka, H., Tandon, A., et al. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202201284 · Cited by 42
Impedance spectroscopy of changes in skin-electrode impedance induced by motion
Cömert, A., & Hyttinen, J. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-149 · Cited by 41
Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review
Nie, L., Berckmans, D., Wang, C., & Li, B. (2020) · Sensors · doi:10.3390/s20082291 · Cited by 46
Imperceptible liquid metal based tattoo for Human-Machine interface on hairy skin
Lin, W., Ai, L., Wang, Y., Yang, X., Liao, J., Pan, Q., Hong, Y., Liu, S., Long, Z., Khoo, B. L., et al. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.151595 · Cited by 40
Li, J., Lee, J. C.-M., Chuang, K.-C., & Chiu, C. (2023) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2022.107378 · Cited by 40
Liu, B., Luo, Z., Zhang, W., Tu, Q., & Jin, X. (2016) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2016.1239951 · Cited by 40
Lee, E., & Cho, G. (2019) · Smart Materials and Structures · doi:10.1088/1361-665x/ab06e0 · Cited by 38
Pedrosa, P., Fiedler, P., Lopes, C., Alves, E., Barradas, N. P., Haueisen, J., Machado, A. V., Fonseca, C., & Vaz, F. (2015) · Plasma Processes and Polymers · doi:10.1002/ppap.201500063 · Cited by 37
Luo, C., Ma, W.-J., Juang, W.-H., Kuo, S.-H., Chen, C.-Y., Tai, P.-C., & Lai, S.-C. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2584648 · Cited by 37
Deep learning approach for ECG-based automatic sleep state classification in preterm infants
Werth, J., Radha, M., Andriessen, P., Aarts, R. M., & Long, X. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101663 · Cited by 39
A new method for manufacturing dry electrodes on textiles. Validation for wearable ECG monitoring
Ferri, J., Llinares, R., Segarra, I., Cebrián, A., Garcı́a-Breijo, E., & Millet, J. (2022) · Electrochemistry Communications · doi:10.1016/j.elecom.2022.107244 · Cited by 35
Fashionable wrist band using highly conductive fabric for electrocardiogram signal monitoring
Das, P. S., Kim, J. W., & Park, J. Y. (2018) · Journal of Industrial Textiles · doi:10.1177/1528083718779427 · Cited by 34
Stephens-Fripp, B., Sencadas, V., Mutlu, R., & Alici, G. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00179 · Cited by 29
Washable and Flexible Screen-Printed Ag/AgCl Electrode on Textiles for ECG Monitoring
Tu, H., Li, X., Lin, X., Lang, C., & Gao, Y. (2023) · Polymers · doi:10.3390/polym15183665 · Cited by 33
A flexible touch sensor based on conductive elastomer for biopotential monitoring applications
Das, P. S., & Park, J.-Y. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.11.008 · Cited by 33
Active flexible concentric ring electrode for non-invasive surface bioelectrical recordings
Prats-Boluda, G., Ye-Lin, Y., Garcı́a-Breijo, E., Ibáñez, J., & Garcia‐Casado, J. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/12/125703 · Cited by 32
Design considerations for effective neural signal sensing and amplification: a review
Sharma, K., & Sharma, R. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab1674 · Cited by 33
Graphite Based Electrode for ECG Monitoring: Evaluation under Freshwater and Saltwater Conditions
Thap, T., Yoon, K., & Lee, J. (2016) · Sensors · doi:10.3390/s16040542 · Cited by 32
A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition
Fong, E.-M., & Chung, W. (2015) · Sensors · doi:10.3390/s150819237 · Cited by 31
Design of a gel-less two-electrode ECG monitor
Richard, E., & Chan, A. D. C. (2010) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2010.5480198 · Cited by 31
Electrochemical behaviour of nanocomposite Agx:TiN thin films for dry biopotential electrodes
Pedrosa, P., Alves, E., Barradas, N. P., Martin, N., Fiedler, P., Haueisen, J., Vaz, F., & Fonseca, C. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.01.082 · Cited by 31
Optically Unobtrusive Zeolite-Based Dry Electrodes for Wearable ECG Monitoring
Pullano, S. A., Kota, D., Kakaraparty, K., Fiorillo, A. S., & Mahbub, I. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3169504 · Cited by 30
Fabrication of Polymer Microneedle Electrodes Coated with Nanoporous Parylene
Nishinaka, Y., Jun, R., Prihandana, G. S., & Miki, N. (2013) · Japanese Journal of Applied Physics · doi:10.7567/jjap.52.06gl10 · Cited by 30
Dielectrics for Non-Contact ECG Bioelectrodes: A Review
Umar, A. H., Othman, M. A., Harun, F. K. C., & Yusof, Y. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3092233 · Cited by 31
Establishing the Input Impedance Requirements of ECG Recording Amplifiers
Maji, S., & Burke, M. J. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2907038 · Cited by 28
A paired stretchable printed sensor system for ambulatory blood pressure monitoring
Kim, J., & Kim, W. S. (2016) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2015.12.030 · Cited by 28
Characterization of dry and wet Electrode-Skin interfaces on different skin treatments for HDsEMG
Cattarello, P., & Merletti, R. (2016) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2016.7533808 · Cited by 28
ECG denoising using a dynamical model and a marginalized particle filter
Lin, C., Bugallo, M. F., Mailhes, C., & Tourneret, J. (2011) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.2011.6190306 · Cited by 28
PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review
Lapsa, D., Janeliukštis, R., Metshein, M., & Selavo, L. (2024) · Applied Sciences · doi:10.3390/app14177451 · Cited by 30
Screen printed MWCNT/PDMS based dry electrode sensor for electrocardiogram (ECG) measurements
Chlaihawi, A. A. J., Narakathu, B. B., Eshkeiti, A., Emamian, S., Avuthu, S. G. R., & Atashbar, M. Z. (2015) · IEEE International Conference on Electro Information Technology · doi:10.1109/eit.2015.7293392 · Cited by 27
Zhou, W., Liu, W., Liu, S., Zhang, C., Shen, Z., & Zhang, G. (2017) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2017.05.032 · Cited by 27
A flexible dry electroencephalogram electrode based on graphene materials
Shao, L., Guo, Y., Liu, W., Sun, T., & Wei, D. (2019) · Materials Research Express · doi:10.1088/2053-1591/ab20a7 · Cited by 27
Wearable graphene-based fabric electrodes for enhanced and long-term biosignal detection
Ali, B., Bidsorkhi, H. C., D’Aloia, A. G., Laracca, M., & Sarto, M. S. (2023) · Sensors and Actuators Reports · doi:10.1016/j.snr.2023.100161 · Cited by 26
Metadata
- Authors
- Gruetzmann, A., Hansen, S., & Müller, J.
- Affiliations
- Hamburg University of Technology (DE)
- ORCID
- Müller, Jörg
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2007-10-12
- Volume
- 28
- Issue
- 11
- Pages
- 1375-1390
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2138886665
- Cited by
- 248
- References
- 12
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 15 · 2023: 21 · 2022: 11 · 2021: 15 · 2020: 19 · 2019: 25 · 2018: 21 · 2017: 9 · 2016: 22 · 2015: 18 · 2014: 15 · 2013: 17 · 2012: 10
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- dry electrodes, ECG monitoring, conductive electrodes, capacitive electrodes, motion artifacts, contact impedance, skin-electrode interface, biopotential monitoring
- MeSH terms
- Elasticity, Electrodes, Equipment Design, Evoked Potentials, Humans, Electrocardiography, Ambulatory, Artifacts, Electric Impedance, Equipment Failure Analysis, Electric Capacitance, Cardiac Electrophysiology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review