Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 193

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A robust fetal ECG detection method for abdominal recordings

Martens, Suzanna M M, Rabotti, Chiara, Mischi, Massimo, Sluijter, Rob J · 2007 · Physiological Measurement

Abstract

In this paper, we propose a new method for FECG detection in abdominal recordings. The method consists of a sequential analysis approach, in which the a priori information about the interference signals is used for the detection of the FECG. Our method is evaluated on a set of 20 abdominal recordings from pregnant women with different gestational ages. Its performance in terms of fetal heart rate (FHR) detection success is compared with that of independent component analysis (ICA). The results show that our sequential estimation method outperforms ICA with a FHR detection rate of 85% versus 60% of ICA. The superior performance of our method is especially evident in recordings with a low signal-to-noise ratio (SNR). This indicates that our method is more robust than ICA for FECG detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/28/4/004

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Adaptive noise cancelling: Principles and applications

    Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 2×

    “To this end, the authors have mainly focused on the removal of the MECG using classical filtering techniques (Bemmel and van der Weide 1966) or estimation techniques, such as adaptive filtering ( Widrow et al 1975 ), subtraction (Meijer 1981) and averaging (Abboud and Sadeh 1989, Cerutti et al 1986).”
    Method
  • A comparison of the noise sensitivity of nine QRS detection algorithms

    Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043 · cited 2×

    “Baseline drift, ECG amplitude modulation due to respiration, power-line interference, electromyogram (EMG) and motion artefacts are among the most significant interference signals that may corrupt ECG recordings (Friesen et al 1990).”
    Background

Show all 2 references

Cited by

See all 193

Metadata

Authors
Martens, S. M. M., Rabotti, C., Mischi, M., & Sluijter, R. J.
Venue
Physiological Measurement
Published
2007-03-07
Volume
28
Issue
4
Pages
373-388
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2122230313
Cited by
193
References
2
FWCI
4.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A robust fetal ECG detection method for abdominal recordings. https://app.cochat.ai/papers/10.1088/0967-3334/28/4/004
The paper
Martens, S. M. M., Rabotti, C., Mischi, M., & Sluijter, R. J. (2007). A robust fetal ECG detection method for abdominal recordings. Physiological Measurement. https://doi.org/10.1088/0967-3334/28/4/004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.