A robust fetal ECG detection method for abdominal recordings
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
In this paper, we propose a new method for FECG detection in abdominal recordings. The method consists of a sequential analysis approach, in which the a priori information about the interference signals is used for the detection of the FECG. Our method is evaluated on a set of 20 abdominal recordings from pregnant women with different gestational ages. Its performance in terms of fetal heart rate (FHR) detection success is compared with that of independent component analysis (ICA). The results show that our sequential estimation method outperforms ICA with a FHR detection rate of 85% versus 60% of ICA. The superior performance of our method is especially evident in recordings with a low signal-to-noise ratio (SNR). This indicates that our method is more robust than ICA for FECG detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
Fast and robust fixed-point algorithms for independent component analysis
Hyvarinen, A. (1999) · IEEE Transactions on Neural Networks · doi:10.1109/72.761722 · Cited by 6,246 · cited 1×
“For this purpose, a number of criteria can be considered on the basis of maximization of non-gaussianity (Hyvarinen 1999), maximum likelihood, minimization of mutual information (Comon 1994), tensorial methods (Cardoso 1989) and nonlinear decorrelation (Jutten and Taleb 2000).”
MethodIndependent Component Analysis
Hyvärinen, A., Karhunen, J., & Oja, E. (2001) · Wiley eBooks · doi:10.1002/0471221317 · Cited by 5,007
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 2×
“To this end, the authors have mainly focused on the removal of the MECG using classical filtering techniques (Bemmel and van der Weide 1966) or estimation techniques, such as adaptive filtering ( Widrow et al 1975 ), subtraction (Meijer 1981) and averaging (Abboud and Sadeh 1989, Cerutti et al 1986).”
MethodA comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043 · cited 2×
“Baseline drift, ECG amplitude modulation due to respiration, power-line interference, electromyogram (EMG) and motion artefacts are among the most significant interference signals that may corrupt ECG recordings (Friesen et al 1990).”
BackgroundAdvanced Methods And Tools for ECG Data Analysis
Clifford, G. D., Azuaje, F. J., & McSharry, P. (2006) · Cited by 808
Source separation using higher order moments
Cardoso, J.-F. (2003) · International Conference on Acoustics, Speech, and Signal Processing · doi:10.1109/icassp.1989.266878 · Cited by 556 · cited 4×
“For this purpose, a number of criteria can be considered on the basis of maximization of non-gaussianity (Hyvarinen 1999), maximum likelihood, minimization of mutual information (Comon 1994), tensorial methods ( Cardoso 1989 ) and nonlinear decorrelation (Jutten and Taleb 2000).”
MethodInfluentialFetal electrocardiogram extraction by blind source subspace separation
de Lathauwer, L., de Moor, B., & Vandewalle, J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841326 · Cited by 502 · cited 1×
“Some authors formulated the FECG detection as a blind source separation (BSS) problem (Callaerts et al 1986, Zarzoso et al 1997, Lathauwer et al 2000).”
BackgroundPlonsey, R. (1999) · Wiley Encyclopedia of Electrical and Electronics Engineering · doi:10.1002/047134608x.w1403 · Cited by 335
Noninvasive fetal electrocardiogram extraction: blind separation versus adaptive noise cancellation
Zarzoso, V., & Nandi, A. K. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.900244 · Cited by 308 · cited 2×
“Furthermore, some authors suggested that this technique performs better than the existing non-blind methods ( Zarzoso and Nandi 2001,”
BackgroundMethodMeyer, C. R., & Keiser, H. N. (1977) · Computers and Biomedical Research · doi:10.1016/0010-4809(77)90021-0 · Cited by 246 · cited 2×
“Other baseline wander removal methods reported in the literature involve the application of a high-pass filter with time-varying cut-off frequency depending on the instantaneous heart rate (Sornmo 1993) or the subtraction of an estimate of the baseline wander using polynomials or cubic splines ( Meyer and Keiser 1977,…”
MethodMonitoring the fetal heart non-invasively: a review of methods
Peters, M., Crowe, J., Piéri, J.-F., Quartero, H., Hayes-Gill, B., James, D., Stinstra, J., & Shakespeare, S. (2001) · Journal of Perinatal Medicine · doi:10.1515/jpm.2001.057 · Cited by 190 · cited 2×
“In abdominal recordings, the MECG amplitude is an order of magnitude larger than the FECG amplitude ( Peters et al 2001 ).”
BackgroundNon-invasive fetal electrocardiography in singleton and multiple pregnancies
Taylor, M. J. O., Smith, M. J., Thomas, M., Green, A. R., Cheng, F., Oseku‐Afful, S., Wee, L., Fisk, N. M., & Gardiner, H. M. (2003) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1046/j.1471-0528.2003.02005.x · Cited by 147
An Improved Adaptive Power Line Interference Canceller for Electrocardiography
Martens, S., Mischi, M., Oei, S. G., & Bergmans, J. W. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883631 · Cited by 142 · cited 1×
“For the elimination of this interference in S2 we have implemented an adaptive noise cancelling technique which iteratively estimates amplitude, frequency and phase of the power-line interference in each channel, and it is specifically tailored for its use in ECG signals (Martens et al 2006).”
MethodSelf-citationECG baseline wander reduction using linear phase filters
van Alste, J. A., van Eck, W., & Herrmann, O. E. (1986) · Computers and Biomedical Research · doi:10.1016/0010-4809(86)90037-6 · Cited by 125 · cited 1×
“However, when the patient is performing exercise, the upper limit may be larger (van Alste et al 1986, Laguna et al 1992).”
BackgroundCerutti, S., Baselli, G., Civardi, S., Ferrazzi, E. M., Marconi, A. M., Pagani, M., & Pardi, G. (1986) · Journal of Perinatal Medicine · doi:10.1515/jpme.1986.14.6.445 · Cited by 117 · cited 4×
“It is based on the method proposed by ( Cerutti et al 1986 ).”
MethodInfluentialTime-varying digital filtering of ECG baseline wander
Sörnmo, L. (1993) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441986 · Cited by 109 · cited 2×
“…in the literature involve the application of a high-pass filter with time-varying cut-off frequency depending on the instantaneous heart rate (Sornmo 1993) or the subtraction of an estimate of the baseline wander using polynomials or cubic splines (Meyer and Keiser 1977, Gradwohl et al 1988,…”
MethodA New Technique for the Suppression of the MECG
Bergveld, P., & Meijer, W. J. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324803 · Cited by 84
A critical appraisal of fetal surveillance
Owen, P., & Patel, N. B. (1994) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(94)90057-4 · Cited by 81
Review of electromagnetic source investigations of the fetal heart
Lewis, M. J. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00121-8 · Cited by 65 · cited 2×
“Doppler ultrasound is now routinely used for the measurement of the fetal heart rate (FHR) during pregnancy and delivery (Lewis 2003).”
MethodCritical Appraisal of Fetal Surveillance
van Geijn, H. P., & Copray, F. J. A. (1994) · Medical Entomology and Zoology · Cited by 64
The effect of changes in the conductive medium on the fetal ECG throughout gestation
Oostendorp, T. F., van Oosterom, A., & Jongsma, H. W. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/4b/002 · Cited by 60 · cited 1×
“Difficulties in obtaining the fetal heart rate in this period have been reported by several authors (Bolte 1961, Bergveld et al 1986, Oldenburg and Macklin 1977, Oostendorp et al 1989, Taylor et al 2003).”
ResultComani, S., Mantini, D., Lagatta, A., Esposito, F., Luzio, S. D., & Romani, G. L. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/019 · Cited by 52 · cited 2×
“A robust fetal ECG detection method for abdominal recordings 375 Comani et al 2004 ).”
MethodExperimental fluid dynamics of aortic stenosis in a model of the human aorta
Yearwood, T. L., Misbach, G. A., & Chandran, K. B. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/1/002 · Cited by 30
Comparison of two methods for removing baseline wander in the ECG
Gradwohl, J. R., Pottala, E. W., Horton, M. R., & Bailey, J. J. (2003) · Computers in cardiology · doi:10.1109/cic.1988.72668 · Cited by 25 · cited 1×
“…involve the application of a high-pass filter with time-varying cut-off frequency depending on the instantaneous heart rate (Sornmo 1993) or the subtraction of an estimate of the baseline wander using polynomials or cubic splines (Meyer and Keiser 1977, Gradwohl et al 1988, McManus et al 1985).”
MethodAntenatal assessment using the FECG obtained via abdominal electrodes
Crowe, J. A., Woolfson, M. S., Hayes‐Gill, B., Peasgood, W., Mohd-Ali, M. A., Huang, Y., Herbert, J., Huang, X. B., Harrison, A., Gibson, N. M., et al. (1996) · Journal of Perinatal Medicine · doi:10.1515/jpme.1996.24.1.43 · Cited by 23 · cited 1×
“The fetal ECG (FECG) can be obtained by applying an electrode on the fetal scalp or by means of ordinary electrodes placed on the mother’s abdomen (Crowe et al 1996).”
MethodInjecting noise for analysing the stability of ICA components
Stefan Harmeling, B., Meinecke, F. C., & Müller, K. (2003) · Signal Processing · doi:10.1016/j.sigpro.2003.10.009 · Cited by 19 · cited 2×
“The P wave, QRS complex and T wave durations are normally about 0.20 s, 0.10 s and 0.40 s, respectively ( Guyton and Hall 1996 ).”
BackgroundMethodInfluentialEstimation of slowly changing components of physiological signals
Raifel, M., & Ron, S. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554769 · Cited by 5 · cited 2×
“However, the first approach requires the detection of the heart rate, which in our case is complicated by the extremely small SNR of the FECG, while the second approach may produce large errors in the baseline wander estimation in the presence of fast changing components and noise ( Raifel and Ron 1997 ).”
Background
Cited by
A Review of Fetal ECG Signal Processing Issues and Promising Directions
Sameni (2010) · The Open Pacing, Electrophysiology & Therapy Journal · doi:10.2174/1876536x01003010004 · Cited by 410
An open-source framework for stress-testing non-invasive foetal ECG extraction algorithms
Andreotti, F., Behar, J., Zaunseder, S., Oster, J., & Clifford, G. D. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/5/627 · Cited by 175
“A variety of TS techniques have been described in the literature (Cerutti et al 1986, Martens et al 2007, Ungureanu et al 2007, 2009, Vullings et al 2009, Di Marco et al 2013, Zaunseder et al 2013, Andreotti et al 2014, Behar et al 2014a, Lipponen and Tarvainen 2014).”
Method
Metadata
- Authors
- Martens, S. M. M., Rabotti, C., Mischi, M., & Sluijter, R. J.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2007-03-07
- Volume
- 28
- Issue
- 4
- Pages
- 373-388
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2122230313
- Cited by
- 193
- References
- 30
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.