Cited by 405Wireless Body Area NetworksNon-Invasive Vital Sign MonitoringWireless Sensor Networks for Data Analysis

Wireless body sensor networks for health-monitoring applications

Open access
Hao, Yang, Foster, Robert·2008·Physiological Measurement

Abstract

Current wireless technologies, such as wireless body area networks and wireless personal area networks, provide promising applications in medical monitoring systems to measure specified physiological data and also provide location-based information, if required. With the increasing sophistication of wearable and implantable medical devices and their integration with wireless sensors, an ever-expanding range of therapeutic and diagnostic applications is being pursued by research and commercial organizations. This paper aims to provide a comprehensive review of recent developments in wireless sensor technology for monitoring behaviour related to human physiological responses. It presents background information on the use of wireless technology and sensors to develop a wireless physiological measurement system. A generic miniature platform and other available technologies for wireless sensors have been studied in terms of hardware and software structural requirements for a low-cost, low-power, non-invasive and unobtrusive system.

Integrity signals

Registry

Crossref · 10.1088/0967-3334/29/11/r01

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In recent years, industry and academia have invested heavily in the development of smaller, less obstructive and more portable devices for the continuous monitoring of sleep.

    “However, in recent years, industry and academia have invested heavily in the development of smaller, less obstructive and more portable devices for the continuous monitoring of sleep38.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hao, Y., & Foster, R.
Affiliations
Queen Mary University of London (GB)
Venue
Physiological Measurement
Published
2008-10-09
Volume
29
Issue
11
Pages
R27-R56
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2030234080
Cited by
404
References
47
Citations by year
2026: 4 · 2025: 11 · 2024: 15 · 2023: 10 · 2022: 16 · 2021: 18 · 2020: 19 · 2019: 21 · 2018: 26 · 2017: 32 · 2016: 37 · 2015: 40 · 2014: 33 · 2013: 36 · 2012: 39
FWCI
1.21
Type
journal article
Language
en
Open access
Locations
  • Physiological Measurement (publishedVersion)
  • PubMed (publishedVersion)
  • Queen Mary Research Online (Queen Mary University of London) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Computer Science › Computer Networks and Communications › Wireless Sensor Networks for Data Analysis
Keywords
wireless body sensor networks, wireless body area networks, health monitoring, physiological signal measurement, wearable medical devices, biomedical implants, low-power sensor systems, non-invasive monitoring
MeSH terms
Delivery of Health Care, Health, Humans, Monitoring, Physiologic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›