Reproducibility of infrared thermography measurements in healthy individuals
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The aim of this study was to investigate the reproducibility of skin surface infrared thermography (IRT) measurements and determine the factors influencing the variability of the measured values. While IRT has been widely utilized in different clinical conditions, there are few available data on the values of the skin temperature patterns of healthy subjects and their reproducibility. We recorded the whole body skin temperatures of sixteen healthy young men with two observers on two consecutive days. The results were compared using intra-class correlations analyses (ICC). The inter-examiner reproducibility of the IRT measurements was high: mean ICC 0.88 (0.73-0.99). The day-to-day stability of thermal patterns varied depending on the measured area: it was high in the core and poor in distal areas. The reproducibility of the side-to-side temperature differences (deltaT) was moderately good between the two observers (mean ICC 0.68) but it was reduced with time, especially in the extremities, mean ICC 0.4 (-0.01-0.83). The results suggest that the IRT technique may represent an objective quantifiable indicator of autonomic disturbances although there are considerable temporal variations in the measured values which are due to both technical factors such as equipment accuracy, measurement environment and technique, and physiological variability of the blood flow, and these factors should be taken into account.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of thermal asymmetry: Part 1: Normal values and reproducibility
Uematsu, S., Edwin, D. H., Jankel, W. R., Kozikowski, J., & Trattner, M. (1988) · Journal of Neurosurgery · doi:10.3171/jns.1988.69.4.0552 · Cited by 252 · cited 7×
“Bilateral nerve involvement can produce false negative findings in sciatica (Uematsu et al 1988b) if the asymptomatic side is used as the control.”
BackgroundResultInfluentialFingertip temperature as an indicator for sympathetic responses
Kistler, A., Mariauzouls, C., & von Berlepsch, K. (1998) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(97)00087-1 · Cited by 207 · cited 1×
“According to the report of Kistler et al (1998), sympathetically induced vascular responses are readily demonstrable in warm fingertips (warmer than 32 ◦C), when sympathetic activity is low.”
MethodSkin temperature side differences – a diagnostic tool for CRPS?
Wasner, G., Schattschneider, J., & Baron, R. (2002) · Pain · doi:10.1016/s0304-3959(01)00470-5 · Cited by 148 · cited 4×
“Furthermore, IRT was found to be reliable as an additive diagnostic tool in the early stages of complex regional pain syndrome (CRPS), both under resting conditions and after various challenges (Wasner et al 2002, Huygen et al 2004, Niehof et al 2006).”
BackgroundMethodInfluentialUematsu, S. (1985) · Journal of neurosurgery · doi:10.3171/jns.1985.62.5.0716 · Cited by 136 · cited 4×
“The values of the whole body skin temperature patterns of the human body have been previously studied in healthy subjects, but mostly in restricted body areas only, or in variable environments (Feldman and Nickoloff 1984, Uematsu 1985, Uematsu et al 1988a, Niu et al 2001).”
BackgroundMethodInfluentialThermal symmetry of skin temperature: normative data of normal subjects in Taiwan.
Niu, H. H., Lui, P.-W., Hu, J. S., Ting, C., Yin, Y., Lo, Y.-C., Liu, L., & Lee, T. Y. (2001) · PubMed · Cited by 106
Normal thermographic standards for the cervical spine and upper extremities
Feldman, F., & Nickoloff, E. L. (1984) · Skeletal Radiology · doi:10.1007/bf00349505 · Cited by 105
Quantification of thermal asymmetry: Part 2: Application in low-back pain and sciatica
Uematsu, S., Jankel, W. R., Edwin, D. H., Kim, W., Kozikowski, J., Rosenbaum, A., & Long, D. M. (1988) · Journal of neurosurgery · doi:10.3171/jns.1988.69.4.0556 · Cited by 104 · cited 7×
“Bilateral nerve involvement can produce false negative findings in sciatica (Uematsu et al 1988b) if the asymptomatic side is used as the control.”
BackgroundResultInfluentialNiehof, S. P., Huygen, F. J. P. M., Weerd, R. W. P. V. D., Westra, M., & Zijlstra, F. J. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-30 · Cited by 100
Togawa, T. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/1/004 · Cited by 100 · cited 1×
“The results were corrected using a skin emissivity factor of 0.97 (Togawa 1989).”
MethodInfluentialHerry, C. L., & Frize, M. (2004) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-3-19 · Cited by 87 · cited 4×
“Therefore, the subjects were requested not to stay in a cold environment before the actual measurements. Since the skin temperature variations are greater when there is cold stress (Frim et al 1990), the δT values of distal parts, which tend to be colder than those of the core (table 2), may represent a more meaningfu…”
InfluentialAllen, J., Frame, J. R., & Murray, A. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/2/312 · Cited by 86 · cited 1×
“…temperature is the same and the ambient temperature is moderately high for the stabilization of the peripheral temperature, e.g. as in the study of Allen et al (2002), or alternatively the experiment must be performed under controlled sympathetic activity (Wasner et al 2002, Niehof et al 2006).”
BackgroundTemperature‐dependent interaction between vasoconstrictor and vasodilator mechanisms in human skin
Oberle, J., Elam, M., KARLSSON, T., & Wallin, B. G. (1988) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1988.tb08353.x · Cited by 75 · cited 2×
“Oberle et al (1988) have found that the same stimuli can cause cutaneous vasodilatation in cold subjects and vasoconstriction in warm subjects.”
BackgroundHuygen, F. J. P. M., Niehof, S. P., Klein, J., & Zijlstra, F. J. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-1037-6 · Cited by 61
Paraspinal Skin Temperature Patterns: An Interexaminer and Intraexaminer Reliability Study
Owens, E. F., Hart, J. F., Donofrio, J. J., Haralambous, J., & Mierzejewski, E. (2004) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2003.12.019 · Cited by 53 · cited 1×
“The reproducibility of the paraspinal temperature measurements and validity of IRT were reported to be high (Owens et al 2004, Roy et al 2006) and the stability of those patterns over time has been described as being good (Hart and Owens 2004).”
MethodBody composition and skin temperature variation
Frim, J., Livingstone, S. D., Reed, L. D., Nolan, R. W., & Limmer, R. E. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.2.540 · Cited by 53 · cited 2×
“The skin temperature recorded by the IRT scan is more stable in the trunk, but in the extremities the variation is great and seems to depend on several endogenous factors such as the activity of the sympathetic nervous system as well as on the environmental temperature (Frim et al 1990).”
Backgroundvan den Heuvel, C. J., Ferguson, S. A., Dawson, D. E., & Gilbert, S. S. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/3/308 · Cited by 41 · cited 1×
“Quantification of the skin temperature using IRT for study purposes was found to be as good as contact thermometry (van den Heuvel et al 2003).”
MethodInfrared ear thermometers—parameters influencing their reading and accuracy
Pušnik, I., & Drnovšek, J. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/6/016 · Cited by 39 · cited 1×
“Problems in measurement accuracy typical for infrared temperature scanning systems were recently described by Pusnik and Drnovsek (2005).”
Facial Thermography, Basis, Protocol, and Clinical Value
Weinstein, S. A., Weinstein, G., Weinstein, E. L., & Gelb, M. (1991) · CRANIO® · doi:10.1080/08869634.1991.11678368 · Cited by 37 · cited 1×
“In the head, a skin surface temperature difference of 0.5 ◦C was considered as a minimum for recognition of a clinically significant thermographic abnormality (Weinstein et al 1991).”
BackgroundInfluentialOerlemans, H. M., Graff, M. J. L., Dijkstra-Hekkink, J. B. G., de Boo, T., Goris, R. J. A., & Oostendorp, R. A. B. (1999) · Journal of Hand Therapy · doi:10.1016/s0894-1130(99)80065-9 · Cited by 36 · cited 1×
“Test–retest and inter-observer reliabilities and, accordingly, the usefulness of the hand skin temperature measurements for monitoring of skin temperature symmetry were good (Oerlemans et al 1999).”
BackgroundAkata, T., Tomoo, K., Yoshino, J., Higashi, M., Fukui, K., & Takahashi, S. (2004) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0403200409 · Cited by 35 · cited 1×
“Consequently, fingertip skin temperature was found to correlate with the laser Doppler flowmetry results (Akata et al 2004), highlighting the usefulness of the fingertip skin temperature monitoring, e.g. for the evaluation of peripheral blood flow during different interventions.”
ResultStability of paraspinal thermal patterns during acclimation
Hart, J. A. L., & Owens, E. F. (2004) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2003.12.006 · Cited by 16 · cited 2×
“The reproducibility of the paraspinal temperature measurements and validity of IRT were reported to be high (Owens et al 2004, Roy et al 2006) and the stability of those patterns over time has been described as being good (Hart and Owens 2004).”
BackgroundMethod
Cited by
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Bouzas Marins, J. C., Arnáiz Lastras, J., Gómez Carmona, P. M., Piñonosa Cano, S., García-Concepción, M. Á., & Sillero-Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 586
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
An Overview of Recent Application of Medical Infrared Thermography in Sports Medicine in Austria
Hildebrandt, C., Raschner, C., & Ammer, K. (2010) · Sensors · doi:10.3390/s100504700 · Cited by 419
Microvascular imaging: techniques and opportunities for clinical physiological measurements
Allen, J., & Howell, K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r91 · Cited by 208
“A number of thermographic studies have investigated skin temperature across the body surface (Uematsu 1986, Zaproudina et al 2008, Goodman et al 1986).”
BackgroundInfrared camera assessment of skin surface temperature—Effect of emissivity
Bernard, V., Staffa, E., Mornstein, V., & Bourek, A. (2013) · Physica Medica · doi:10.1016/j.ejmp.2012.09.003 · Cited by 177
Metadata
- Authors
- Zaproudina, N., Varmavuo, V., Airaksinen, O., & Närhi, M.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2008-04-01
- Volume
- 29
- Issue
- 4
- Pages
- 515-524
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2074829677
- Cited by
- 246
- References
- 21
- FWCI
- 5.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.