The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Investigating a smartphone imaging unit for photoplethysmography
Abstract
Current-generation smartphones boast a video unit comprising a camera next to a white light emitting diode and this configuration would be suitable for reflection-mode bio-optical sensing and imaging applications. We demonstrate reflection photoplethysmographic (PPG) imaging using this technology on the index finger of a male volunteer during rest and immediately after performing a short run. The returned signals carry useful PPG signals and were used, for example, to compute change in heart rate. Our results are encouraging, especially in the area of personal and home-based care applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Low-frequency photoplethysmograph signals
Harness, J. B., & Marjanovic, D. Z. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/4/009 · Cited by 6
Cited by
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“The other is the contact type for short-distance measurements, such as placing the finger on the mobile phone camera to cover the entire camera view and using the phone camera flash LED light (white light) to illuminate the finger [47].”
BackgroundmHealth for mental health: Integrating smartphone technology in behavioral healthcare.
Luxton, D. D., McCann, R. A., Bush, N. E., Mishkind, M. C., & Reger, G. M. (2011) · Professional Psychology: Research and Practice · doi:10.1037/a0024485 · Cited by 809
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452
Mobile phone-based biosensing: An emerging “diagnostic and communication” technology
Quesada-González, D., & Merkoçi, A. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.062 · Cited by 272
Metadata
- Authors
- Jonathan, E., & Leahy, M.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-09-24
- Volume
- 31
- Issue
- 11
- Pages
- N79-N83
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2001140692
- Cited by
- 177
- References
- 1
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Investigating a smartphone imaging unit for photoplethysmography. https://app.cochat.ai/papers/10.1088/0967-3334/31/11/n01
- The paper
- Jonathan, E., & Leahy, M. (2010). Investigating a smartphone imaging unit for photoplethysmography. Physiological Measurement. https://doi.org/10.1088/0967-3334/31/11/n01
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.