Low-frequency photoplethysmograph signals
Open accessThe claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Variation in the quasi-DC component of PPG is due to many factors: optical properties of the tissue, average blood volume, respiration, vasomotor activity, vasoconstrictor waves, Traube Hering Meyer waves, and thermoregulation.
“The variation in the quasi-DC component is due to many factors: the optical properties of the tissue, average blood volume, respiration, vasomotor activity, vasoconstrictor waves, Traube Hering Meyer waves, and thermoregulation [4,5,6,7,8,9,10,11,12,13,14].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [13]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Spontaneous rhythms in physiological control systems
HYNDMAN, B. W., KITNEY, R. I., & SAYERS, B. M. (1971) · Nature · doi:10.1038/233339a0 · Cited by 361 · see citing works
Burton, A. C. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.3.437 · Cited by 333 · see citing works
Mayer waves history and methodology
Peňáz, J. (1978) · Medical Entomology and Zoology · Cited by 126 · see citing works
Respiratory control of heart rate
Ahmed, A., Harness, J. B., & Mearns, A. J. (1982) · European Journal of Applied Physiology · doi:10.1007/bf00952248 · Cited by 79 · see citing works
Self-citationPhotoplethysmography- fundamental aspects of the optical properties of blood in motion
Roberts, V. C. (1982) · Transactions of the Institute of Measurement and Control · doi:10.1177/014233128200400205 · Cited by 54 · see citing works
Observations on the photoplethysmograph pulse derived from a laser Doppler flowmeter
Almond, N. E., & Cooke, E. D. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/2/003 · Cited by 18 · see citing works
到, 高. (1984) · The Annals of physiological anthropology · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
- Authors
- Harness, J. B., & Marjanovic, D. Z.
- Affiliations
- University of Bradford (GB)
- Venue
- Clinical Physics and Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1989-11
- Volume
- 10
- Issue
- 4
- Pages
- 365-367
- ISSN
- 0143-0815 (ISSN-L)
- OpenAlex
- W2087304954
- Cited by
- 6
- References
- 7
- Citations by year
- 2021: 1 · 2012: 1
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Clinical Physics and Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- photoplethysmography, low-frequency signals
- MeSH terms
- Adult, Fingers, Humans, Male, Plethysmography, Respiration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review