Segmentation of heart sound recordings by a duration-dependent hidden Markov model
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Digital stethoscopes offer new opportunities for computerized analysis of heart sounds. Segmentation of heart sound recordings into periods related to the first and second heart sound (S1 and S2) is fundamental in the analysis process. However, segmentation of heart sounds recorded with handheld stethoscopes in clinical environments is often complicated by background noise. A duration-dependent hidden Markov model (DHMM) is proposed for robust segmentation of heart sounds. The DHMM identifies the most likely sequence of physiological heart sounds, based on duration of the events, the amplitude of the signal envelope and a predefined model structure. The DHMM model was developed and tested with heart sounds recorded bedside with a commercially available handheld stethoscope from a population of patients referred for coronary arterioangiography. The DHMM identified 890 S1 and S2 sounds out of 901 which corresponds to 98.8% (CI: 97.8-99.3%) sensitivity in 73 test patients and 13 misplaced sounds out of 903 identified sounds which corresponds to 98.6% (CI: 97.6-99.1%) positive predictivity. These results indicate that the DHMM is an appropriate model of the heart cycle and suitable for segmentation of clinically recorded heart sounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A tutorial on hidden Markov models and selected applications in speech recognition
Rabiner, L. R. (1989) · Proceedings of the IEEE · doi:10.1109/5.18626 · Cited by 22,743 · cited 5×
“Solving equation (6) requires the calculation of all combinations of Q , which can be shown to correspond to T ∗ N T multiplications (Rabiner 1989).”
BackgroundMethodInfluentialProbable Inference, the Law of Succession, and Statistical Inference
Wilson, E. B. (1927) · Journal of the American Statistical Association · doi:10.1080/01621459.1927.10502953 · Cited by 4,476
Baum, L. E., Petrie, T., Soules, G., & Weiss, N. (1970) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177697196 · Cited by 4,297
Interval Estimation for a Binomial Proportion
Brown, L. D., Cai, T. T., & DasGupta, A. (2001) · Statistical Science · doi:10.1214/ss/1009213286 · Cited by 3,538
An Introduction to Medical Statistics.
(1931) · Journal of the American Medical Association · doi:10.1001/jama.1931.02730150055037 · Cited by 2,084
Heart sound segmentation algorithm based on heart sound envelogram
Liang, H., Lukkarinen, S., & Hartimo, I. (2002) · Computers in Cardiology 1997 · doi:10.1109/cic.1997.647841 · Cited by 414
An Introduction to Medical Statistics
D., F. N., & Lancaster, H. O. (1975) · Biometrics · doi:10.2307/2529447 · Cited by 405
A heart sound segmentation algorithm using wavelet decomposition and reconstruction
Huiying, L., Sakari, L., & Iiro, H. (2002) · Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136) · doi:10.1109/iembs.1997.757028 · Cited by 189
Detection of the first and second heart sound using probabilistic models
Gamero, L. G., & Watrous, R. L. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280519 · Cited by 77
Automatic segmentation of heart sound signals using hidden markov models
Ricke, A. D., Povinelli, R. J., & Johnson, M. T. (2005) · Computers in cardiology · doi:10.1109/cic.2005.1588266 · Cited by 68
Accessing heart dynamics to estimate durations of heart sounds
Nigam, V., & Priemer, R. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/6/010 · Cited by 64
Detection of the first heart sound using a time-delay neural network
Oskiper, T., & Watrous, R. L. (2003) · Computers in cardiology · doi:10.1109/cic.2002.1166828 · Cited by 63
A method for accurate localization of the first heart sound and possible applications
Ahlstrom, C. H. G., Länne, T., Ask, P., & Johansson, A. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/3/011 · Cited by 28
Nigam, V., & Priemer, R. (2007) · Physiological Measurement · doi:10.1088/0967-3334/29/1/003 · Cited by 16
Cited by
An open access database for the evaluation of heart sound algorithms
Liu, C., Springer, D., Li, Q., Moody, B., Juan, R. A., Chorro, F. J., Castells, F., Roig, J. M., Silva, I., Johnson, A. E. W., et al. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/12/2181 · Cited by 820
Self-citationLogistic Regression-HSMM-based Heart Sound Segmentation
Springer, D., Tarassenko, L., & Clifford, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2475278 · Cited by 518
Ensemble of Feature:based and Deep learning:based Classifiers for Detection of Abnormal Heart Sounds
Potes, C., Parvaneh, S., Rahman, A., & Conroy, B. (2016) · 2016 Computing in Cardiology Conference (CinC) · doi:10.22489/cinc.2016.182-399 · Cited by 314
A systematic survey of computer-aided diagnosis in medicine: Past and present developments
Yanase, J., & Triantaphyllou, E. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.112821 · Cited by 303
“Currently, there are many algorithms for adaptive segmentation, such as the Matching Pursuit algorithm [Nieblas, et al., 2013], hidden Markov models [Schmidt, et al., 2010], and the tunable-Q wavelet transform [Patidar and Pachori, 2013].”
MethodAlgorithms for Automatic Analysis and Classification of Heart Sounds–A Systematic Review
Dwivedi, A. K., Imtiaz, S. A., & Rodriguez-Villegas, E. (2019) · IEEE Access · doi:10.1109/access.2018.2889437 · Cited by 195
“Similarly, identification of S2 (SHSD) at the event level, was reported in [25], [29], [45], [47], [52], [57], [64], [87]–[89], [92], [94], [96], [100], and [104], achieving a mean accuracy of 93.”
BackgroundMethodInfluential
Metadata
- Authors
- Schmidt, S. E., Holst-Hansen, C., Graff, C., Toft, E., & Struijk, J. J.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-03-05
- Volume
- 31
- Issue
- 4
- Pages
- 513-529
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2020459286
- Cited by
- 297
- References
- 14
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.