Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation
Abstract
Pulse oximeters are monitors that noninvasively measure heart rate and blood oxygen saturation (SpO2). Unfortunately, pulse oximetry is prone to artifacts which negatively impact the accuracy of the measurement and can cause a significant number of false alarms. We have developed an algorithm to segment pulse oximetry signals into pulses and estimate the signal quality in real time. The algorithm iteratively calculates a signal quality index (SQI) ranging from 0 to 100. In the presence of artifacts and irregular signal morphology, the algorithm outputs a low SQI number. The pulse segmentation algorithm uses the derivative of the signal to find pulse slopes and an adaptive set of repeated Gaussian filters to select the correct slopes. Cross-correlation of consecutive pulse segments is used to estimate signal quality. Experimental results using two different benchmark data sets showed a good pulse detection rate with a sensitivity of 96.21% and a positive predictive value of 99.22%, which was equivalent to the available reference algorithm. The novel SQI algorithm was effective and produced significantly lower SQI values in the presence of artifacts compared to SQI values during clean signals. The SQI algorithm may help to guide untrained pulse oximeter users and also help in the design of advanced algorithms for generating smart alarms.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Out of several pulse-to-pulse SQIs [10,[49][50][51], only the one in [10] has been tested in long-term wrist PPGs acquired outside the laboratory setting and was therefore implemented in this study.”
From Modeling of artifacts in the wrist photoplethysmogram: Application to the detection of life-threatening arrhythmias (2021) · cites this paper as [50]
In the citing paper
“Karlen et al. created an algorithm with 96.21% sensitivity and 99.2% positive predictive value for good pulses using repeated Gaussian filters and cross-correlation [168].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [168]
In the citing paper
“With this algorithm, Karlen et al. were able to distinguish where motion artifacts occurred in a beat-to-beat manner.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [168]
Citations
Cites
Lima, A. P., Beelen, P., & Bakker, J. (2002) · Critical Care Medicine · doi:10.1097/00003246-200206000-00006 · Cited by 479
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400
The peripheral pulse wave: Information overlooked
Murray, W. B., & Foster, P. A. (1996) · The Journal of Clinical Monitoring · doi:10.1007/bf02077634 · Cited by 231
An Automatic Beat Detection Algorithm for Pressure Signals
Aboy, M., McNames, J., Thong, T., Tsunami, D., Ellenby, M. S., & Goldstein, B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.855725 · Cited by 216
Signal processing methods for pulse oximetry
Rusch, T. L., Sankar, R. T., & Scharf, J. E. (1996) · Computers in Biology and Medicine · doi:10.1016/0010-4825(95)00049-6 · Cited by 185
The Effect of Motion on Pulse Oximetry and Its Clinical Significance
Petterson, M. T., Begnoche, V. L., & Graybeal, J. M. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000278134.47777.a5 · Cited by 177
Signal quality measures for pulse oximetry through waveform morphology analysis
Sukor, J. A., Redmond, S. J., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/3/008 · Cited by 166
Lee, B., Han, J., Baek, H. J., Shin, J. H., Park, K. S., & Yi, W. J. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/12/003 · Cited by 155
CapnoBase: Signal database and tools to collect, share and annotate respiratory signals
Karlen, W., Turner, M., Cooke, E., Dumont, G. A., & Ansermino, J. M. (2010) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000087887 · Cited by 114
Kalman Filter Based Adaptive Reduction Of Motion Artifact From Photoplethysmographic Signal
Seyedtabaii, S., & Seyedtabaii, L. (2008) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1333655 · Cited by 59
Research works printed but not linked: 9
- 2003, ANSI/AAMI EC57
- Farooq U Jang D G Park J H Park S H, 2010, Annu. Int. Conf. IEEE Engineering in Medicine and Biology Society, 4582
- Karlen W Petersen C Gow J Ansermino J M Dumont G A Fred A Filipe J Gamboa H, 2012, BIOSTEC 2011: 4th Int. Joint Conf. on Biomedical Engineering Systems and Technologies, 31
- Karlen W Turner M Cooke E Dumont G A Ansermino J M, 2010, STA: Annu. Meet. of the Society for Technology in Anesthesia, 25
- Lovell N H Redmond S J Basilakis J Celler B G, 2010, 12th IEEE Int. Conf. on e-Health Networking Applications and Services (Healthcom), 81
- Madhav K V Ram M R Krishna E H Reddy K N Reddy K A, 2011, Int. Conf. on Communications and Signal Processing (ICCSP 2011), 452
- Seyedtabaii S, 2008, World Acad. Sci. Eng. Technol., 37, 173
- Weng J Ye Z Weng J, 2005, 27th Annu. Int. Conf. IEEE Engineering in Medicine and Biology Society, 41
- Wood L B Asada H H, 2006, 28th Annu. Int. Conf. of the IEEE Engineering in Medicine and Biology Society, 3525
Cited by
Sorted by citations
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 514
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Mejía‐Mejía, E., Budidha, K., Abay, T. Y., May, J. M., & Kyriacou, P. A. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00779 · Cited by 178
Assessing mental stress from the photoplethysmogram: a numerical study
Charlton, P. H., Celka, P., Farukh, B., Chowienczyk, P., & Alastruey, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aabe6a · Cited by 131
van Lier, H. G., Pieterse, M. E., Garde, A., Postel, M. G., de Haan, H. A., Vollenbroek-Hutten, M. M. R., Schraagen, J. M., & Noordzij, M. L. (2019) · Behavior Research Methods · doi:10.3758/s13428-019-01263-9 · Cited by 143
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
Development of a Screening Tool for Sleep Disordered Breathing in Children Using the Phone Oximeter™
Garde, A., Dehkordi, P., Karlen, W., Wensley, D., Ansermino, J. M., & Dumont, G. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112959 · Cited by 122
Scardulla, F., Cosoli, G., Spinsante, S., Poli, A., Iadarola, G., Pernice, R., Busacca, A., Pasta, S., Scalise, L., & D’Acquisto, L. (2023) · Measurement · doi:10.1016/j.measurement.2023.113150 · Cited by 134
Wearable Photoplethysmography for Cardiovascular Monitoring.
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · KTUePubl (Repository of Kaunas University of Technology) · doi:10.17863/cam.81148 · Cited by 113
Dao, D. K., Salehizadeh, S. M. A., Noh, Y., Chong, J. W., Cho, C. H., McManus, D., Darling, C. E., Mendelson, Y., & Chon, K. H. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2612059 · Cited by 104
Carek, A. M., Conant, J., Joshi, A. N., Kang, H., & Inan, O. T. (2017) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3130905 · Cited by 103
Lin, Y.-Y., Wu, H., Hsu, C.-A., Huang, P.-C., Huang, Y.-H., & Lo, Y. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2636778 · Cited by 104
A Supervised Approach to Robust Photoplethysmography Quality Assessment
Pereira, T., Gadhoumi, K., Ma, M., Liu, X., Xiao, R., Colorado, R. A., Keenan, K. J., Meisel, K. M., & Hu, X. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2909065 · Cited by 80
Chong, J. W., Dao, D. K., Salehizadeh, S. M. A., McManus, D. D., Darling, C. E., Chon, K. H., & Mendelson, Y. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1080-y · Cited by 79
Roy, M. S., Gupta, R., Chandra, J. K., Sharma, K. D., & Talukdar, A. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2829488 · Cited by 76
Reddy, G. N. K., Manikandan, M. S., & Murty, N. V. L. N. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.2971132 · Cited by 73
A Multimodal Data Fusion Technique for Heartbeat Detection in Wearable IoT Sensors
John, A., Redmond, S. J., Cardiff, B., & John, D. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3093112 · Cited by 70
Liu, S.-H., Li, R.-X., Wang, J.-J., Chen, W., & Su, C.-H. (2020) · Applied Sciences · doi:10.3390/app10134612 · Cited by 58
Optimized Signal Quality Assessment for Photoplethysmogram Signals Using Feature Selection
Mohagheghian, F., Han, D., Peitzsch, A. G., Nishita, N., Ding, E., Dickson, E. L., DiMezza, D., Otabil, E. M., Noorishirazi, K., Scott, J., et al. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3158582 · Cited by 57
Implementation of Artifact Detection in Critical Care: A Methodological Review
Nizami, S., Green, J. R., & McGregor, C. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2013.2243724 · Cited by 52
Derks, Y. P., Klaassen, R., Westerhof, G. J., Bohlmeijer, E. T., & Noordzij, M. L. (2019) · JMIR mHealth and uHealth · doi:10.2196/13479 · Cited by 45
Pereira, T., Ding, C., Gadhoumi, K., Tran, N., Colorado, R. A., Meisel, K. M., & Hu, X. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab5b84 · Cited by 53
Moscato, S., Giudice, S. L., Massaro, G., & Chiari, L. (2022) · Sensors · doi:10.3390/s22155831 · Cited by 51
Dehkordi, P., Garde, A., Karlen, W., Wensley, D., Ansermino, J. M., & Dumont, G. A. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611059 · Cited by 52
Mejía‐Mejía, E., May, J. M., Elgendi, M., & Kyriacou, P. A. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00447-y · Cited by 42
Guo, Z., Ding, C., Hu, X., & Rudin, C. D. (2021) · Physiological Measurement · doi:10.1088/1361-6579/ac3b3d · Cited by 40
Zheng, Y., Wu, C., Cai, P., Zhong, Z., Huang, H., & Jiang, Y. (2023) · Internet of Things · doi:10.1016/j.iot.2023.101007 · Cited by 40
Sabeti, E., Reamaroon, N., Mathis, M. R., Gryak, J., Sjoding, M. W., & Najarian, K. (2019) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2019.100222 · Cited by 40
Quality Assessment for the Photoplethysmogram (PPG)
Orphanidou, C. (2017) · SpringerBriefs in bioengineering · doi:10.1007/978-3-319-68415-4_3 · Cited by 39
Adaptive template matching of photoplethysmogram pulses to detect motion artefact
Lim, P. K., Ng, S., Lovell, N. H., Yu, Y. P., Tan, M. P., McCombie, D. B., Lim, E., & Redmond, S. J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aadf1e · Cited by 39
Papini, G. B., Fonseca, P. M., Aubert, X. L., Overeem, S., Bergmans, J. W. M., & Vullings, R. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036776 · Cited by 36
Garde, A., Hoppenbrouwer, X. L. R., Dehkordi, P., Zhou, G., Rollinson, A. U., Wensley, D., Dumont, G. A., & Ansermino, J. M. (2018) · Sleep Medicine · doi:10.1016/j.sleep.2018.08.027 · Cited by 36
Dynamic ROI based on K-means for remote photoplethysmography
Feng, L., Po, L.-M., Xu, X., Li, Y., Cheung, T. C.-H., Cheung, K.-W., & Fang, Y. (2015) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2015.7178182 · Cited by 38
Liu, S.-H., Wang, J.-J., Chen, W., Pan, K., & Su, C.-H. (2020) · Applied Sciences · doi:10.3390/app10041476 · Cited by 35
Mejía‐Mejía, E., May, J. M., Elgendi, M., & Kyriacou, P. A. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106222 · Cited by 36
Garde, A., Dehkordi, P., Wensley, D., Ansermino, J. M., & Dumont, G. A. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320174 · Cited by 33
PPGMotion: Model-based detection of motion artifacts in photoplethysmography signals
Maity, A. K., Veeraraghavan, A., & Sabharwal, A. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103632 · Cited by 32
Papini, G. B., Fonseca, P. M., Eerikäinen, L. M., Overeem, S., Bergmans, J. W. M., & Vullings, R. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aae7f8 · Cited by 32
Huthart, S., Elgendi, M., Zheng, D., Stansby, G. P., & Allen, J. (2020) · Frontiers in Digital Health · doi:10.3389/fdgth.2020.619692 · Cited by 35
A Survey of Photoplethysmography and Imaging Photoplethysmography Quality Assessment Methods
Desquins, T., Bousefsaf, F., Pruski, A., & Maaoui, C. (2022) · Applied Sciences · doi:10.3390/app12199582 · Cited by 35
Schäck, T., Harb, Y. S., Muma, M., & Zoubir, A. M. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036773 · Cited by 30
Alam, S., Gupta, R., & Sharma, K. D. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3067238 · Cited by 30
Roy, M. S., Roy, B., Gupta, R., & Sharma, K. D. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3028935 · Cited by 29
Garde, A., Zhou, G., Raihana, S., Dunsmuir, D. T., Karlen, W., Dekhordi, P., Huda, T. M., Arifeen, S. E., Larson, C. P., Kissoon, N. “., et al. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-011094 · Cited by 27
Identifying individual sleep apnea/hypoapnea epochs using smartphone-based pulse oximetry
Garde, A., Dekhordi, P., Ansermino, J. M., & Dumont, G. A. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591408 · Cited by 27
Song, J., Li, D., Ma, X., Teng, G., & Wei, J. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.05.020 · Cited by 25
Paliakaitė, B., Petrėnas, A., Sološenko, A., & Marozas, V. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102421 · Cited by 24
Photoplethysmogram Signal Quality Evaluation by Unsupervised Learning Approach
Roy, M. S., Gupta, R., & Sharma, K. D. (2020) · 2020 IEEE Applied Signal Processing Conference (ASPCON) · doi:10.1109/aspcon49795.2020.9276733 · Cited by 24
Cugmas, B., Štruc, E., & Spīgulis, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aaf433 · Cited by 24
Dehkordi, P., Garde, A., Karlen, W., Petersen, C. L., Wensley, D., Dumont, G. A., & Ansermino, J. M. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/2/187 · Cited by 22
Sleep stage classification in children using photoplethysmogram pulse rate variability
Dehkordi, P., Garde, A., Karlen, W., Wensley, D., Ansermino, J. M., & Dumont, G. A. (2014) · Computing in cardiology · Cited by 22
Wander, J. D., & Morris, D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/12/2543 · Cited by 22
PPGFeat: a novel MATLAB toolbox for extracting PPG fiducial points
Abdullah, S., Hafid, A., Folke, M., Lindén, M., & Kristoffersson, A. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1199604 · Cited by 20
Prabhakar, S. K., Rajaguru, H., & Kim, S. (2020) · Diagnostics · doi:10.3390/diagnostics10100763 · Cited by 17
Vardoulis, O., Saponas, T. S., Morris, D., Villar, N., Smith, G., Patel, S., & Tan, D. S. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.06.022 · Cited by 16
LSTM-based real-time signal quality assessment for blood volume pulse analysis
Gao, H., Zhang, C., Pei, S., & Wu, X. (2023) · Biomedical Optics Express · doi:10.1364/boe.477143 · Cited by 15
Prasun, P., Mukhopadhyay, S., & Gupta, R. (2021) · Measurement Science and Technology · doi:10.1088/1361-6501/ac2d5b · Cited by 15
The Impact of Contact Force on Signal Quality Indices in Photoplethysmography Measurements
Cause, J. L., Morillo, Á. S., Naranjo, J. C. G., Stiens, J. H., & da Silva, B. (2024) · Applied Sciences · doi:10.3390/app14135704 · Cited by 14
Tabei, F., Zaman, R., Foysal, K. H., Kumar, R., Kim, Y., & Chong, J. W. (2019) · PLoS ONE · doi:10.1371/journal.pone.0218248 · Cited by 13
A Generalized Signal Quality Estimation Method for IoT Sensors
John, A., Cardiff, B., & John, D. (2020) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas45731.2020.9180546 · Cited by 14
A Pulse Signal Preprocessing Method Based on the Chauvenet Criterion
Ni, W., Qi, J., Liu, L., & Li, S. (2019) · Computational and Mathematical Methods in Medicine · doi:10.1155/2019/2067196 · Cited by 14
Wiens, M. O., Gan, H., Barigye, C., Zhou, G., Kumbakumba, E., Kabakyenga, J. K., Kissoon, N. “., Ansermino, J. M., Karlen, W., Larson, C. P., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0118055 · Cited by 13
Sivanjaneyulu, Y., Manikandan, M. S., Boppu, S., & Cenkeramaddi, L. R. (2024) · IEEE Access · doi:10.1109/access.2024.3464231 · Cited by 12
On-Device Multi-Level Signal Quality Aware Compression for Energy-Efficient Wearable PPG Sensing
Alam, S., Gupta, R., & Sharma, K. D. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3234171 · Cited by 12
Abdullah, S., Hafid, A., Folke, M., Lindén, M., & Kristoffersson, A. (2023) · Electronics · doi:10.3390/electronics12051174 · Cited by 13
Night to night variability of pulse oximetry features in children at home and at the hospital
Hoppenbrouwer, X. L. R., Rollinson, A. U., Dunsmuir, D. T., Ansermino, J. M., Dumont, G. A., Nijeweme-d’Hollosy, W. O., Veltink, P. H., & Garde, A. (2021) · Physiological Measurement · doi:10.1088/1361-6579/ac278e · Cited by 10
Sarkar, S., & Ghosh, A. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106240 · Cited by 9
MLFusion: Multilevel Data Fusion using CNNs for atrial fibrillation detection
John, A., Parhi, K. K., Cardiff, B., & John, D. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.109901 · Cited by 10
Zhang, J., Tüshaus, L., Martínez, N. N., Moreo, M., Verástegui, H., Hartinger, S. M., Mäusezahl, D., & Karlen, W. (2018) · JMIR mhealth and uhealth · doi:10.2196/11896 · Cited by 9
Robust Assessment of Photoplethysmogram Signal Quality in the Presence of Atrial Fibrillation
Pereira, T., Gadhoumi, K., Ma, M., Colorado, R. A., Keenan, K. J., Meisel, K. M., & Hu, X. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.254 · Cited by 8
Tüshaus, L., Moreo, M., Zhang, J., Hartinger, S. M., Mäusezahl, D., & Karlen, W. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00478.2018 · Cited by 8
Influence of Photoplethysmogram Signal Quality on Pulse Arrival Time during Polysomnography
Rinkevičius, M., Charlton, P. H., Bailón, R., & Marozas, V. (2023) · Sensors · doi:10.3390/s23042220 · Cited by 11
Sleep/Wake Classification Using Cardiorespiratory Features Extracted from Photoplethysmogram
Dehkordi, P., Garde, A., Dumont, G. A., & Ansermino, J. M. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.294-147 · Cited by 8
Roy, M. S., Bag, P., & Gupta, R. (2019) · IEEE Region 10 Symposium (TENSYMP) · doi:10.1109/tensymp46218.2019.8971035 · Cited by 7
Huang, L., Yan, J., Cai, S., Guo, R. J., Yan, H., & Wang, Y. (2022) · BioMed Research International · doi:10.1155/2022/2766321 · Cited by 7
Recognition of correct finger placement for photoplethysmographic imaging
Karlen, W., Lim, J. M.-Y., Ansermino, J. M., Dumont, G. A., & Scheffer, C. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611288 · Cited by 7
Identification of Pulse Onset on Cerebral Blood Flow Velocity Waveforms: A Comparative Study
Asgari, S., Canac, N., Hamilton, R., & Scalzo, F. (2019) · BioMed Research International · doi:10.1155/2019/3252178 · Cited by 7
Segmentation of Motion Artifacts in Wearable PPG Signals Using Lightweight Neural Networks
Bolpagni, M., Campanella, S., Gabrielli, S., & Palma, L. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3561604 · Cited by 6
COVID-19 Detection Using Photoplethysmography and Neural Networks
Lombardi, S., Francia, P., Deodati, R., Calamai, I., Luchini, M., Spina, R., & Bocchi, L. (2023) · Sensors · doi:10.3390/s23052561 · Cited by 8
Learning based Quality Indicator Aiding Heart Rate Estimation in Wrist-Worn PPG
Lutin, E., Biswas, D., Simoes-Capela, N., Hoof, C. A. V., & Helleputte, N. V. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630910 · Cited by 6
A Novel Abnormal Segments Detection Method for Photopletysmography Signal
Teng, Y., Ge, L., & Chou, Y. (2018) · Chinese Control Conference (CCC) · doi:10.23919/chicc.2018.8483815 · Cited by 6
Pankaj, Maan, P., Kumar, M., Kumar, A., & Komaragiri, R. (2025) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-025-10415-4 · Cited by 11
OPRA: A fast on-line signal quality estimator for pulsatile signals
Pflugradt, M., Moeller, B., & Orglmeister, R. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.10.183 · Cited by 5
Correntropy-Based Pulse Rate Variability Analysis in Children with Sleep Disordered Breathing
Garde, A., Dehkordi, P., Ansermino, J. M., & Dumont, G. A. (2017) · Entropy · doi:10.3390/e19060282 · Cited by 5
Airflow from nasal pulse oximetry in the screening of obstructive sleep apnea
Hoppenbrouwer, X. L. R., Fabius, T. M., Eijsvogel, M., de Jongh, F. H., & Garde, A. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857586 · Cited by 5
Signal Quality Analysis in Pulse Oximetry: Modelling and Detection of Motion Artifact
Clarke, G. (2015) · doi:10.22215/etd/2015-10956 · Cited by 5
Mula, S., Zangróniz, R., Martín, Ó. A., Rieta, J. J., & Alcaraz, R. (2025) · IEEE Access · doi:10.1109/access.2025.3604652 · Cited by 4
Shin, H. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108952 · Cited by 4
Non-invasive Estimation of Oxygen Saturation Level in Blood
Devi, C. N., & Alex, Z. C. (2017) · Indian Journal of Science and Technology · doi:10.17485/ijst/2017/v10i5/108778 · Cited by 4
Photoplethysmogram analysis and applications: An Integrative Review (Preprint)
Shin, H., Park, J., Seok, H. S., & Kim, S. (2020) · JMIR Biomedical Engineering · doi:10.2196/25567 · Cited by 4
Recognising Cardiac Abnormalities in Wearable Device Photoplethysmography (PPG) with Deep LearningPreprint
Whiting, S., Moreland, S., Costello, J., Colopy, G. W., & McCann, C. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1807.04077 · Cited by 4
Shahrbabak, S. M., Bouzid, Z., Inan, O. T., & Hahn, J. (2025) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae0c4b · Cited by 3
Remote physiological monitoring of neck blood vessels with a high-speed camera
Cao, M., Saiko, G., & Douplik, A. (2025) · Advanced Optical Technologies · doi:10.3389/aot.2025.1536415 · Cited by 3
Bose, A., Mukherjee, S., Chandra, J. K., Gupta, R., & Ghosh, D. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3351256 · Cited by 3
Huang, S., Jafari, R., & Mortazavi, B. J. (2024) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2024.3398444 · Cited by 3
Case Study on Measurement of SpO2 from PPG Signals in the Presence of Motion Artifact
Subhagya, D. S., Keshava Murthy., C., Aruna, N., Janardhan, L., & Ramakrishna, H. S. (2017) · International Conference on Recent Advances in Electronics and Communication Technology (ICRAECT) · doi:10.1109/icraect.2017.71 · Cited by 3
Motion Artifact Mitigation for Wearable Pulse Oximetry
Williamson, J. R., Patel, T., Singh, N., Siegel, A. M., Telfer, B. A., Trebicka, R., Welsh, B., & Hoyt, R. W. (2018) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2018.8329662 · Cited by 3
Alexithymia in borderline personality pathology: From theory to a biosensor application
Derks, Y. P. M. J. (2022) · doi:10.3990/1.9789464217896 · Cited by 2
Systolic Blood Pressure in Anesthetized Bitches Measured with Photoplethysmography
Vaccarin, C. V., Gasparotto, J. C., Vargas, D., Libardoni, R. D. N., Velasquez, O. G., da Silva, C. T., Segat, H. J., Lopes, C., Müller, D. C. D. M., & Soares, A. V. (2022) · ACTA SCIENTIAE VETERINARIAE · doi:10.22456/1679-9216.124686 · Cited by 1
Metadata
- Authors
- Karlen, W., Kobayashi, K., Ansermino, J. M., & Dumont, G. A.
- Affiliations
- University of British Columbia (CA)
- Corresponding author
- Karlen, W
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-09-18
- Volume
- 33
- Issue
- 10
- Pages
- 1617-1629
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2160347936
- Cited by
- 123
- References
- 18
- Citations by year
- 2026: 10 · 2025: 8 · 2024: 7 · 2023: 10 · 2022: 12 · 2021: 11 · 2020: 10 · 2019: 11 · 2018: 13 · 2017: 7 · 2016: 9 · 2015: 6 · 2014: 6 · 2013: 3
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Hirosaki University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmogram, pulse oximetry, signal quality estimation, pulse detection, Gaussian filtering, cross correlation function, signal artifacts, real-time monitoring, smart alarms, heart rate monitoring
- MeSH terms
- Adolescent, Adult, Aged, Algorithms, Child, Child, Preschool, Humans, Infant, Middle Aged, Quality Control, Signal Processing, Computer-Assisted, Normal Distribution, Databases, Factual, Photoplethysmography, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review