The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Load-Independent Contributions From Motor-Unit Synchronization to Human Physiological Tremor
Abstract
This study describes two load-independent rhythmic contributions from motor-unit synchronization to normal physiological tremor, which occur in the frequency ranges 1–12 Hz and 15–30 Hz. In common with previous studies, we use increased inertial loading to identify load-independent components of physiological tremor. The data consist of simultaneous recordings of tremor acceleration from the third finger, a surface electromyogram (EMG), and the discharges of pairs of single motor units from the extensor digitorum communis (EDC) muscle, collected from 13 subjects, and divided into 2 data sets: 106 records with the finger unloaded and 84 records with added mass from 5 to 40 g. Frequency domain analysis of motor-unit data from individual subjects reveals the presence of two distinct frequency bands in motor-unit synchronization, 1–12 Hz and 15–30 Hz. A novel Fourier-based population analysis demonstrates that the same two rhythmic components are present in motor-unit synchronization across both data sets. These frequency components are not related to motor-unit firing rates. The same frequency bands are present in the correlation between motor-unit activity and tremor and between surface EMG activity and tremor, despite a significant alteration in the characteristics of the tremor with increased inertial loading. A multivariate analysis demonstrates conclusively that motor-unit synchronization is the source of these contributions to normal physiological tremor. The population analysis suggests that single motor-unit discharges can predict an average of 10% of the total tremor signal in these two frequency bands. Rectified surface EMG can predict an average of 20% of the tremor; therefore within our population of recordings, the two components of motor-unit synchronization account for an average of 20% of the total tremor signal, in the frequency ranges 1–12 Hz and 15–30 Hz. Our results demonstrate that normal physiological tremor is a complex signal containing information relating to motor-unit synchronization in different frequency bands, and lead to a revised definition of normal physiological tremor during low force postural contractions, which is based on using both the tremor spectra and the correlation between motor-unit activity and tremor to characterize the load-dependent and the load-independent components of tremor. In addition, both physiological tremor and rectified EMG emerge as powerful predictors of the frequency components of motor-unit synchronization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Halliday, D. M., Rosenberg, J. R., Amjad, A. M., Breeze, P., Conway, B. A., & Farmer, S. F. (1995) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(96)00009-0 · Cited by 1,107
Self-citationMcAuley, J. H., Rothwell, J. C., & Marsden, C. D. (1997) · Experimental Brain Research · doi:10.1007/pl00005662 · Cited by 285
Motor unit discharge and force tremor in skill- and strength-trained individuals
Semmler, J. G., & Nordstrom, M. A. (1998) · Experimental Brain Research · doi:10.1007/s002210050316 · Cited by 237
Physiologic and essential tremor
Elble, R. J. (1986) · Neurology · doi:10.1212/wnl.36.2.225 · Cited by 231
Mechanical factors in human tremor frequency
Stiles, R. N., & Randall, J. E. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.3.324 · Cited by 191
Comparison of electromyogram spectra with force spectra during human elbow tremor.
Matthews, P. B., & Muir, R. B. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013254 · Cited by 70
Passive mechanical properties of the wrist and physiological tremor.
Lakie, M., Walsh, E. G., & Wright, G. W. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.6.669 · Cited by 47
Hömberg, V, Reiners, K., Hefter, H., & Freund, H.-J. (1986) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(86)90087-8 · Cited by 35
Cited by
Mechanisms that contribute to differences in motor performance between young and old adults
Enoka, R. M., Christou, E. A., Hunter, S. K., Kornatz, K. W., Semmler, J. G., Taylor, A. M., & Tracy, B. L. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00084-6 · Cited by 562
Yao, W., Fuglevand, R. J., & Enoka, R. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.441 · Cited by 473
Human Cortical Muscle Coherence Is Directly Related to Specific Motor Parameters
Kilner, J. M., Baker, S. N., Salenius, S., Hari, R., & Lemon, R. N. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-23-08838.2000 · Cited by 418
Gilbertson, T., Lalo, E., Doyle, L., Di Lazzaro, V., Cioni, B., & Brown, P. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.1762-05.2005 · Cited by 396
EEG–EMG, MEG–EMG and EMG–EMG frequency analysis: physiological principles and clinical applications
Grosse, P., Cassidy, M. J., & Brown, P. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00223-7 · Cited by 391
Metadata
- Authors
- Halliday, D. M., Conway, B. A., Farmer, S. F., & Rosenberg, J. R.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1999-08-01
- Volume
- 82
- Issue
- 2
- Pages
- 664-675
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2215658989
- Cited by
- 224
- References
- 8
- FWCI
- 10.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Load-Independent Contributions From Motor-Unit Synchronization to Human Physiological Tremor. https://app.cochat.ai/papers/10.1152/jn.1999.82.2.664
- The paper
- Halliday, D. M., Conway, B. A., Farmer, S. F., & Rosenberg, J. R. (1999). Load-Independent Contributions From Motor-Unit Synchronization to Human Physiological Tremor. Journal of Neurophysiology. https://doi.org/10.1152/jn.1999.82.2.664
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.