Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.

Percutaneous method for single-catheter multiple monophasic action potential recordings during magnetocardiographic mapping in spontaneously breathing rodents

Abstract

To test the feasibility of a novel method to combine magnetocardiographic (MCG) estimate of ventricular repolarization (VR) and multiple monophasic action potential (MultiMAP) recording in spontaneously breathing rodents with percutaneous sub-xyphoid epicardial placement of a MCG-compatible amagnetic catheter (AC), ten Wistar rats (WRs) and ten guinea pigs (GPs) were studied. Under fluoroscopic control, the AC was moved until four stable MAPs were recorded (fixed inter-electrode distance of 1.2 mm). 36-channel DC-SQUID (sensitivity 20 fT Hz(-½)) were used for MCG mapping. MAPs, differentially amplified (BW: DC-500 Hz), were digitized at 1 kHz. AC pacing provided local ventricular effective refractory period (VERP) estimate. MAP duration (MAPd) was measured at 50% and 90% levels of repolarization. Simultaneous MCG mapping and MultiMAP recording were successful in all animals. Average MAPd50% and MAPd90% were shorter in WRs than in GPs (26.4 ± 2.9 ms versus 110.6 ± 14.3 ms and 60.7 ± 5.4 ms versus 127.7 ± 15.3 ms, respectively). VERP was 51 ± 4.8 ms in WRs and 108.4 ± 12.9 ms in GPs, respectively. The MAP amplitude was 16.9 ± 4.5 in WRs and 16.2 ± 4.2 in GPs. MAP and MCG parameters of VR were in good agreement. All animals survived the procedure. Two also survived a second invasive study; one was followed up until natural death at 52 months. Percutaneous MultiMAP recording is minimally invasive, usually avoids animal sacrifice, is compatible with simultaneous surface MCG mapping and might be used for experimental validation of MCG VR abnormality, to study the arrhythmogenic potential of new drugs and/or animal models of ventricular arrhythmias.

Overview

Integrity signals

Registry

Crossref · 10.1088/0967-3334/33/3/521

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 45 references

Research works printed but not linked: 3

  1. Kim M S, 2002, Korean J. Med., 62, 42
  2. Nenonen J, 2005, SQUID Handbook
  3. Veisterä H Fenici R Lötjönen J, 2004, Proc. 14th Int. Conf. Biomagnetism (Boston), 415

Cited by

See all 9

Metadata

Authors
Brisinda, D., Sorbo, A. R., Venuti, A., & Fenici, R.
Affiliations
Università Cattolica del Sacro Cuore (IT)
Venue
Physiological Measurement
Published
2012-02-29
Volume
33
Issue
3
Pages
521-534
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2081990219
Cited by
6
References
45
Citations by year
2025: 3 · 2023: 1 · 2018: 1 · 2016: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • Physiological Measurement (publishedVersion)
  • PubMed (publishedVersion)
Funders
Ministero dell’Istruzione, dell’Università e della Ricerca
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
magnetocardiography, monophasic action potential, multimaps, ventricular repolarization, effective refractory period, percutaneous catheter insertion, dc SQUID, ventricular arrhythmias, rodent models, Wistar rats, guinea pig
MeSH terms
Action Potentials, Animals, Electrocardiography, Female, Guinea Pigs, Heart, Male, Rats, Wistar, Body Surface Potential Mapping, Rats, Magnetocardiography, Catheters

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Percutaneous method for single-catheter multiple monophasic action potential recordings during magnetocardiographic mapping in spontaneously breathing rodents. https://app.cochat.ai/papers/10.1088/0967-3334/33/3/521
The paper
Brisinda, D., Sorbo, A. R., Venuti, A., & Fenici, R. (2012). Percutaneous method for single-catheter multiple monophasic action potential recordings during magnetocardiographic mapping in spontaneously breathing rodents. Physiological Measurement. https://doi.org/10.1088/0967-3334/33/3/521

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.