The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Current status of monophasic action potential recording: theories, measurements and interpretations
Open accessAbstract
Time for primary review 26 days. Monophasic action potentials (MAPs) are extracellularly recorded wave forms that, under optimal conditions, can reproduce the repolarization time course of transmembrane action potentials (TAPs) with high fidelity [1–3]. While TAP recordings require the impalement of an individual cardiac cell by a glass-microelectrode and therefore generally are limited to in vitro preparations, MAPs can be recorded from the endocardium and epicardium of the in situ beating heart, including that of human subjects. MAP recordings therefore are suitable for studying the characteristics of local myocardial electrophysiology, especially of repolarization, in the clinical setting. This has made MAP recordings an important bridge between basic and clinical electrophysiology in multiple areas of arrhythmia research [4]. Despite the growing use of the MAP recording method, there still is surprisingly little hard data on the exact mechanism by which MAPs are created and recorded. New methods for recording MAPs recently have been proposed, and new theories and models have been suggested to explain the mechanisms that underlie the genesis of the MAP signal. There have been attempts to record MAPs from sites within the myocardial wall, an effort spurred on by the discovery that mid-myocardial cells (M-cells) have different repolarization characteristics than either epicardial or endocardial cells [5], and these different characteristics have been found to be important for the development of torsade de pointes arrhythmias [6]. This article attempts to review the available information on the MAP genesis and its particular recording modes. It also highlights some important MAP quality criteria and guidelines for correct interpretation of MAPs and how to avoid artifacts. Last but not least, important differences between unipolar and bipolar recordings of both MAPs and conventional electrograms will be discussed, as they pertain to the fidelity and spatial resolution of these recordings. The first MAP was recorded in 1882 by Burdon-Sanderson and Page [7]who placed one electrode on the intact epicardial surface and the other on an injured site of a frog heart, and thereby captured the phasic electrical changes of the cardiac cycle on a charcoal-covered recording drum. Burdon-Sanderson and Page produced this injury by cutting into the myocardium, and termed these recordings monophasic action currents (later to be replaced by monophasic action potentials). Until then, electrodes placed on intact heart tissue had been recording multiphasic deflections, similar to those recorded today in the human electrophysiology laboratory by conventional electrode catheters; so the term monophasic was a logical choice. It was believed for several decades that such monophasic action potentials could only be produced by traumatic tissue injury or cellular disruption. Methods such as cutting, stabbing or burning of a myocardial site were invented to produce monophasic ‘injury’ currents [8]. In 1934, Schütz [9]introduced the suction electrode for experimental MAP recording. In 1969, Korsgren et al. [10]used a suction electrode catheter in a patient and recorded, for the first time, MAPs from the in situ ventricular endocardium. This pioneering step subsequently was amplified by the work of Olsson and coworkers [11–13]who refined the suction electrode technique and demonstrated the value of MAP recording in exploring human cardiac electrophysiology, mainly of the right atrium. Injury was still deemed necessary and to do this ‘cautiously’ in the human heart by suction technique required the use of three-way stop cocks, bubble filters to prevent air emboli and other precautions [13]. Because this technique was cumbersome and raised patient safety concerns, the suction electrode technique never gained wide acceptance in the clinical electrophysiological laboratory (nor FDA approval). The first nontraumatic method for recording MAPs was published in 1935 by Jochim et al. [14]. These authors demonstrated that MAPs can be obtained by simply pressing an electrode against the epicardium of the toad ventricle while another electrode merely touched the nearby epicardium (Fig. 1). They also showed that the MAP is positive with respect to zero if the pressure electrode is the active electrode (connected to the positive amplifier input). This important observation went largely unnoticed for many years. However, their observation was in both methodology and interpretation surprisingly similar to the current principle of recording MAPs by contact electrode. The ‘contact electrode technique’ for clinical use was developed between 1980 and 1983 by Franz et al. [15, 16]. With the contact electrode technique, MAP recordings can be obtained from the human endocardium or epicardium without suction but rather by pressing a nonpolarizable electrode gently against the endocardium or epicardium. Catheters and probes for endocardial and epicardial MAP rec
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Franz, M. R., Karasik, P. L., Li, C., Moubarak, J., & Chavez, M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00385-9 · Cited by 301
Self-citation
Cited by
Brisinda, D., Sorbo, A. R., Venuti, A., & Fenici, R. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/521 · Cited by 6
Metadata
- Authors
- Franz, M.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-01-01
- Volume
- 41
- Issue
- 1
- Pages
- 25-40
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2129124697
- Cited by
- 173
- References
- 1
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current status of monophasic action potential recording: theories, measurements and interpretations. https://app.cochat.ai/papers/10.1016/s0008-6363(98)00268-5
- The paper
- Franz, M. (1999). Current status of monophasic action potential recording: theories, measurements and interpretations. Cardiovascular Research. https://doi.org/10.1016/s0008-6363(98)00268-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.