Automatic ECG quality scoring methodology: mimicking human annotators
Open accessThe DOI matches its Crossref record.
Abstract
An algorithm to determine the quality of electrocardiograms (ECGs) can enable inexperienced nurses and paramedics to record ECGs of sufficient diagnostic quality. Previously, we proposed an algorithm for determining if ECG recordings are of acceptable quality, which was entered in the PhysioNet Challenge 2011. In the present work, we propose an improved two-step algorithm, which first rejects ECGs with macroscopic errors (signal absent, large voltage shifts or saturation) and subsequently quantifies the noise (baseline, powerline or muscular noise) on a continuous scale. The performance of the improved algorithm was evaluated using the PhysioNet Challenge database (1500 ECGs rated by humans for signal quality). We achieved a classification accuracy of 92.3% on the training set and 90.0% on the test set. The improved algorithm is capable of detecting ECGs with macroscopic errors and giving the user a score of the overall quality. This allows the user to assess the degree of noise and decide if it is acceptable depending on the purpose of the recording.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Real-Time Signal Quality-Aware ECG Telemetry System for IoT-Based Health Care Monitoring
Satija, U., Ramkumar, B., & Sabarimalai Manikandan, M. (2017) · IEEE Internet of Things Journal · doi:10.1109/jiot.2017.2670022 · Cited by 370
A Review of Signal Processing Techniques for Electrocardiogram Signal Quality Assessment
Satija, U., Ramkumar, B., & Manikandan, M. S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2810957 · Cited by 295
“3) Automatic ECG Quality Scoring Method: Johannesen and Galeotti [34] presented a two-stage algorithm, which first discards the ECG recordings with macroscopic errors (missing lead, large amplitude shifts, or device saturation) and then subsequently classifies the ECG noises.”
MethodA machine learning approach to multi-level ECG signal quality classification
Li, Q., Rajagopalan, C., & Clifford, G. D. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2014.09.002 · Cited by 229
Automated ECG Noise Detection and Classification System for Unsupervised Healthcare Monitoring
Satija, U., Ramkumar, B., & Manikandan, M. S. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2686436 · Cited by 180
“Galeotti [17] proposed an automatic ECG quality scoring methodology based on the QRS feature extraction and rule-set.”
MethodGambarotta, N., Aletti, F., Baselli, G., & Ferrario, M. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1453-5 · Cited by 45
Metadata
- Authors
- Johannesen, L., & Galeotti, L.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-08-17
- Volume
- 33
- Issue
- 9
- Pages
- 1479-1489
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2030837440
- Cited by
- 70
- References
- 0
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic ECG quality scoring methodology: mimicking human annotators. https://app.cochat.ai/papers/10.1088/0967-3334/33/9/1479
- The paper
- Johannesen, L., & Galeotti, L. (2012). Automatic ECG quality scoring methodology: mimicking human annotators. Physiological Measurement. https://doi.org/10.1088/0967-3334/33/9/1479
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.