Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 180

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Automated ECG Noise Detection and Classification System for Unsupervised Healthcare Monitoring

Satija, Udit, Ramkumar, Barathram, Manikandan, M. Sabarimalai · 2018 · IEEE Journal of Biomedical and Health Informatics

Abstract

OBJECTIVE: Automatic detection and classification of noises can play a vital role in the development of robust unsupervised electrocardiogram (ECG) analysis systems. This paper proposes a novel unified framework for automatic detection, localization, and classification of single and combined ECG noises. METHODS: The proposed framework consists of the modified ensemble empirical mode decomposition (CEEMD), the short-term temporal feature extraction, and the decision-rule-based noise detection and classification. In the proposed framework, ECG signals are first decomposed using the modified CEEMD algorithm for discriminating the ECG components from the noises and artifacts. Then, the short-term temporal features such as maximum absolute amplitude, number of zerocrossings, and local maximum peak amplitude of the autocorelation function are computed from the extracted high-frequency and low-frequency signals. Finally, a decision rule-based algorithm is presented for detecting the presence of noises and classifying the processed ECG signals into six signal groups: noise-free ECG, ECG+BW, ECG+MA, ECG+PLI, ECG+BW+PLI, and ECG+BW+MA. RESULTS: The proposed framework is rigorously evaluated on five benchmark ECG databases and the real-time ECG signals. The proposed framework achieves an average sensitivity of 99.12%, specificity of 98.56%, and overall accuracy of 98.90% in detecting the presence of noises. Classification results show that the framework achieves an average sensitivity, positive predictivity, and classification accuracy of 98.93%, 98.39%, and 97.38%, respectively. CONCLUSION: The proposed framework not only achieves better noise detection and classification rates than the current state-of-the-art methods but also accurately localizes short bursts of noises with low endpoint delineation errors. SIGNIFICANCE: Extensive studies on benchmark databases demonstrate that the proposed framework is more suitable for reducing false alarm rates and selecting appropriate noise-specific denoising techniques in automated ECG analysis applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2017.2686436

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 180

Metadata

Authors
Satija, U., Ramkumar, B., & Manikandan, M. S.
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2018-05
Volume
22
Issue
3
Pages
722-732
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W2597701414
Cited by
180
References
1
FWCI
8.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated ECG Noise Detection and Classification System for Unsupervised Healthcare Monitoring. https://app.cochat.ai/papers/10.1109/jbhi.2017.2686436
The paper
Satija, U., Ramkumar, B., & Manikandan, M. S. (2018). Automated ECG Noise Detection and Classification System for Unsupervised Healthcare Monitoring. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2017.2686436

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.