The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
National and local diagnostic reference levels for adult 18F-FDG and CT in Jordanian PET/CT: findings and implications in practice
Abstract
This study aims to report the findings of Jordanian national diagnostic reference level (NDRL) survey for fluorodeoxyglucose (18 F-FDG) and local diagnostic reference level (LDRL) of computed tomography (CT) used for attenuation correction and anatomical localisation (AC-AL); and AC and diagnostic CT (AC-DX) within the context of whole-body WB and half-body HB adult oncology PET/CT scanning. Two-structured questionnaires were prepared to gather the necessary information: dosimetry data, patient demographics, equipment specification, and acquisition protocols for identified 18 F-FDG PET/CT procedures. The NDRL and achievable dose were reported based on the 75th and 50th percentiles for 18 F-FDG administered activity (AA), respectively. The LDRL was reported based on the 50th percentile for (CTDI vol) and (DLP). Data from 562 patients from four Jordanian PET/CT centres were collected. The survey revealed that Jordanian NDRL for AA (303 MBq) was within the acceptable range compared to the published-peer NDRL data (240–590 MBq). However, the 18 F-FDG AA varied across the participated PET/CT centres. The reported LDRL CTDI vol and DLP of CT used for (AC-AL) was 4.3 mGy and 459.3 mGy.cm for HB CT scan range, and 4.1 mGy and 659.9 mGy.cm for WB CT scans. The reported LDRL for CTDI vol and DLP for HB CT was higher when compared with the United Kingdom (3.2 mGy and 310 mGy.cm). Concurrently, in the context of WB CT, the reported values (i.e. CTDIvol and DLP) were also higher than both Kuwait (3.6 mGy and 659 mGy.cm) and Slovenia (3.6 mGy and 676 mGy.cm). The reported HB CT(AC-DX) was higher than Nordic, New Zealand and Swiss NDRLs and for WB (AC-DX) CT it was higher than Swiss NDRLs. This study reported the first Jordanian NDRL for 18 F-FDG and LDRL for HB and WB CT associated with 18 F-FDG PET/CT scans. This data is useful for Jordanian PET/CT centres to compare their LDRL to the suggested DRLs and utilise it in the process of optimising CT radiation doses.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In Jordan, an increasing emphasis on radiation protection and quality assurance in medical imaging has initiated endeavors to create and revise national CT diagnostic reference levels (DRLs).6–8”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [8]
Citations
Cites
ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A. (2017) · Annals of the ICRP · doi:10.1177/0146645317717209 · Cited by 1,043
Whole-Body PET/CT Scanning: Estimation of Radiation Dose and Cancer Risk
Huang, B., Law, M. W.-M., & Khong, P. (2009) · Radiology · doi:10.1148/radiol.2511081300 · Cited by 523
State of the art in total body PET
Vandenberghe, S., Moskal, P., & Karp, J. S. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00290-2 · Cited by 394
Hart, D. B., HILLIER, M. C., & Wall, B. F. (2008) · British Journal of Radiology · doi:10.1259/bjr/12568539 · Cited by 208
Ultra-low dose CT attenuation correction for PET/CT
Xia, T., Alessio, A. M., Man, B. D., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/2/309 · Cited by 95
Roch, P., & Aubert, B. (2012) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncs152 · Cited by 89
The 2020 national diagnostic reference levels for nuclear medicine in Japan
Abe, K., Hosono, M., Igarashi, T., et al. (2020) · Annals of Nuclear Medicine · doi:10.1007/s12149-020-01512-4 · Cited by 73
A national survey of computed tomography doses in hybrid PET-CT and SPECT-CT examinations in the UK
Iball, G. R., Bebbington, N. A., Burniston, M. T., et al. (2017) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000672 · Cited by 70
National survey of patient doses from whole-body FDG PET-CT examinations in France in 2011
Étard, C., Célier, D., Roch, P., et al. (2012) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncs066 · Cited by 64
Kwon, H. W., Kim, J. P., Lee, H. J., et al. (2016) · Journal of Korean Medical Science · doi:10.3346/jkms.2016.31.s1.s69 · Cited by 59
Research works printed but not linked: 1
- Botros, 2009, Diagnostic reference activities for nuclear medicine procedures in Australia and New Zealand derived from the 2008 survey, ANZ Nucl. Med., 40, 2, 10.3316/informit.731406688136618 · DOI
Cited by
Sorted by citations
Masoomi, M., Al-Kandari, L., Al-Shammeri, I., Elrahman, H., & Al-Shammeri, J. (2023) · BJR|Open · doi:10.1093/bjro/tzae032 · Cited by 1
Oglat, A., Shdaifat, S., Sayah, M., Abukonna, A., & Khogali, W. (2026) · Drug, Healthcare and Patient Safety · doi:10.2147/dhps.s595721
Metadata
- Authors
- Alhorani, Q., Alkhybari, E., Rawashdeh, M., Sabarudin, A., Latiff, R. A., Al-Ibraheem, A., & Mohamad, M.
- Affiliations
- Prince Sattam Bin Abdulaziz University (SA)
- Jordan University of Science and Technology (JO)
- National University of Malaysia (MY)
- ORCID
- Venue
- Journal of Radiological Protection
- Publisher
- IOP Publishing
- Published
- 2024-03-01
- Volume
- 44
- Issue
- 1
- Pages
- 011512
- ISSN
- 0952-4746 (ISSN-L)
- 1361-6498
- OpenAlex
- W4392087464
- Cited by
- 6
- References
- 36
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Radiological Protection (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Keywords
- diagnostic reference levels, 18F-FDG PET/CT, CT radiation dose, radiation dose, attenuation correction, whole-body CT, CTDIvol, dose-length product, Jordan, tumor imaging, radiation protection, CT acquisition protocols
- MeSH terms
- Positron Emission Tomography Computed Tomography, Diagnostic Reference Levels, Adult, Humans, Jordan, Radiation Dosage, Reference Values, Tomography, X-Ray Computed, Fluorodeoxyglucose F18
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review