The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
High dynamic range 3D measurements with fringe projection profilometry: a review
Abstract
In optical metrology, fringe projection is considered to be one of the most reliable techniques for recovering the shape of objects. For this technique, however, it is challenging to measure objects with a large variation in surface reflectivity, e.g. a scenario containing both dark and bright objects. Researchers have thus developed various approaches to high dynamic range (HDR) three-dimensional (3D) measurements over the years. In this paper, we present an overview of these techniques, as well as a new and definitive classification for them. We implement a set of representative techniques to measure objects with different characteristics of reflectance and discuss the advantages and constraints of the techniques according to the comparative results. Moreover, challenging problems and future research directions are discussed to advance HDR 3D measurement techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple View Geometry in Computer Vision
Hartley, R., & Zisserman, A. (2004) · doi:10.1017/cbo9780511811685 · Cited by 21,070
A Taxonomy and Evaluation of Dense Two-Frame Stereo Correspondence Algorithms
Scharstein, D., & Szeliski, R. (2002) · International Journal of Computer Vision · doi:10.1023/a:1014573219977 · Cited by 6,740
High-accuracy stereo depth maps using structured light
Scharstein, D., & Szeliski, R. (2003) · 2003 IEEE Computer Society Conference on Computer Vision and Pattern Recognition, 2003. Proceedings. · doi:10.1109/cvpr.2003.1211354 · Cited by 1,542
Cited by
Status, challenges, and future perspectives of fringe projection profilometry
Xu, J., & Zhang, S. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106193 · Cited by 469
Calibration of fringe projection profilometry: A comparative review
Feng, S., Zuo, C., Zhang, L., Tao, T., Hu, Y., Yin, W., Qian, J., & Chen, Q. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2021.106622 · Cited by 347
Self-citation
Metadata
- Authors
- Feng, S., Zhang, L., Zuo, C., Tao, T., Chen, Q., & Gu, G.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2018-11-05
- Volume
- 29
- Issue
- 12
- Pages
- 122001
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2892786419
- Cited by
- 232
- References
- 3
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High dynamic range 3D measurements with fringe projection profilometry: a review. https://app.cochat.ai/papers/10.1088/1361-6501/aae4fb
- The paper
- Feng, S., Zhang, L., Zuo, C., Tao, T., Chen, Q., & Gu, G. (2018). High dynamic range 3D measurements with fringe projection profilometry: a review. Measurement Science and Technology. https://doi.org/10.1088/1361-6501/aae4fb
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.