We present a full-scale clinical prototype system for in vivo range verification of proton pencil-beams using the prompt gamma-ray spectroscopy method. The detection system consists of eight LaBr 3 scintillators and a tungsten collimator, mounted on a rotating frame. Custom electronics and calibration algorithms have been developed for the measurement of energy- and time-resolved gamma-ray spectra during proton irradiation at a clinical dose rate. Using experimentally determined nuclear reaction cross sections and a GPU-accelerated Monte Carlo simulation, a detailed model of the expected gamma-ray emissions is created for each individual pencil-beam. The absolute range of the proton pencil-beams is determined by minimizing the discrepancy between the measurement and this model, leaving the absolute range of the beam and the elemental concentrations of the irradiated matter as free parameters. The system was characterized in a clinical-like situation by irradiating different phantoms with a scanning pencil-beam. A dose of 0.9 Gy was delivered to a cm 3 target with a beam current of 2 nA incident on the phantom. Different range shifters and materials were used to test the robustness of the verification method and to calculate the accuracy of the detected range. The absolute proton range was determined for each spot of the distal energy layer with a mean statistical precision of 1.1 mm at a 95% confidence level and a mean systematic deviation of 0.5 mm, when aggregating pencil-beam spots within a cylindrical region of 10 mm radius and 10 mm depth. Small range errors that we introduced were successfully detected and even large differences in the elemental composition do not affect the range verification accuracy. These results show that our system is suitable for range verification during patient treatments in our upcoming clinical study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Allison, J., Amako, K., Apostolakis, J., Arce, P., Asai, M., Aso, T., Bagli, E., Bagulya, A., Banerjee, S., Barrand, G., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2016.06.125 · Cited by 4,194
TOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H. (2012) · Medical Physics · doi:10.1118/1.4758060 · Cited by 1,140
XCOM: Photon Cross Section Database (version 1.2)
Berger, M. J., Hubbell, J. H., Seltzer, S. M., Coursey, J. S., & Zucker, D. S. (1999) · Cited by 862
Schneider, W., Bortfeld, T., & Schlegel, W. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/314 · Cited by 831
Self-citationA Fast Voxel Traversal Algorithm for Ray Tracing
Amanatides, J., & Woo, A. (1987) · doi:10.2312/egtp.19871000 · Cited by 660
In vivoproton range verification: a review
Knopf, A. C., & Lomax, A. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/15/r131 · Cited by 620
Ryan, C. G., Clayton, E., Griffin, W. L., Sie, S. H., & Cousens, D. R. (1988) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(88)90063-8 · Cited by 510 · cited 1×
“The stopping powers that we measured are consistent with the measurements by Saito and Sagara (2017) and Hünemohr et al (2014).”
ResultHünemohr, N., Krauß, B., Tremmel, C., Ackermann, B., Jäkel, O., & Greilich, S. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/1/83 · Cited by 236
Proton range verification through prompt gamma-ray spectroscopy
Verburg, J. M., & Seco, J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/23/7089 · Cited by 201
Self-citationGPU-based fast Monte Carlo dose calculation for proton therapy
Jia, X., Schümann, J., Paganetti, H., & Jiang, S. B. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7783 · Cited by 177 · cited 1×
“Proton energy spectrum The stopping of the pencil-beams within the patient or phantom is modeled using an extended version of gPMC (Jia et al 2012, Qin et al 2016), which is a CUDA GPU-accelerated Monte Carlo code specifically designed for proton therapy simulation. The simulations are performed on a Tesla K40 GPU acc…”
MethodHueso-González, F., Enghardt, W., Fiedler, F., Golnik, C., Janssens, G., Petzoldt, J., Prieels, D., Priegnitz, M., Romer, K. E., Smeets, J., et al. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/16/6247 · Cited by 121
Self-citationAdequate margin definition for scanned particle therapy in the incidence of intrafractional motion
Knopf, A. C., Boye, D., Lomax, A., & Mori, S. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/17/6079 · Cited by 116
Simulation of prompt gamma-ray emission during proton radiotherapy
Verburg, J., Shih, H. A., & Seco, J. C. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/17/5459 · Cited by 111
Self-citationWohlfahrt, P., Möhler, C., Richter, C., & Greilich, S. (2017) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.09.025 · Cited by 99
Absolute prompt-gamma yield measurements for ion beam therapy monitoring
Pinto, M., Bajard, M., Brons, S., Chevallier, M., Dauvergne, D., Dedes, G., Rydt, M. D., Freud, N., Krimmer, J., Tessa, C. L., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/2/565 · Cited by 64
Qin, N., Botas, P., Giantsoudi, D., Schuemann, J., Tian, Z., Jiang, S. B., Paganetti, H., & Jia, X. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/20/7347 · Cited by 43
Automated Monte Carlo Simulation of Proton Therapy Treatment Plans
Verburg, J., Grassberger, C., Dowdell, S., Schuemann, J., Seco, J. C., & Paganetti, H. (2015) · Technology in Cancer Research & Treatment · doi:10.1177/1533034615614139 · Cited by 38
Self-citationSchumann, A., Priegnitz, M., Schoene, S., Enghardt, W., Rohling, H., & Fiedler, F. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/19/6919 · Cited by 24
Cited by
Roadmap: proton therapy physics and biology
Paganetti, H., Beltran, C., Both, S., Dong, L., Flanz, J., Furutani, K., Grassberger, C., Grosshans, D. R., Knopf, A.-C., Langendijk, J. A., et al. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abcd16 · Cited by 175
Metadata
- Authors
- Hueso-González, F., Rabe, M., Ruggieri, T. A., Bortfeld, T., & Verburg, J. M.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2018-09-17
- Volume
- 63
- Issue
- 18
- Pages
- 185019
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2883616247
- Cited by
- 197
- References
- 18
- FWCI
- 19.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.