Harmonization strategies for multicenter radiomics investigations
The DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.
Abstract
Carrying out large multicenter studies is one of the key goals to be achieved towards a faster transfer of the radiomics approach in the clinical setting. This requires large-scale radiomics data analysis, hence the need for integrating radiomic features extracted from images acquired in different centers. This is challenging as radiomic features exhibit variable sensitivity to differences in scanner model, acquisition protocols and reconstruction settings, which is similar to the so-called ‘batch-effects’ in genomics studies. In this review we discuss existing methods to perform data integration with the aid of reducing the unwanted variation associated with batch effects. We also discuss the future potential role of deep learning methods in providing solutions for addressing radiomic multicentre studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image-to-Image Translation with Conditional Adversarial Networks
Isola, P., Zhu, J.-Y., Zhou, T., & Efros, A. A. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.632 · Cited by 22,930
An Introduction to Support Vector Machines and Other Kernel-based Learning Methods
Cristianini, N., & Shawe-Taylor, J. (2000) · doi:10.1017/cbo9780511801389 · Cited by 13,855
Adjusting batch effects in microarray expression data using empirical Bayes methods
Johnson, W. E., Li, C., & Rabinovic, A. (2007) · Biostatistics · doi:10.1093/biostatistics/kxj037 · Cited by 8,658 · cited 2×
“Recently, some improvements to ComBat were introduced to allow more flexibility in choosing a reference (Modified(M)-ComBat (Johnson et al 2007, Da-ano et al 2020)) to avoid such issues, and improving robustness of the estimation by relying on bootstrap (Bootstrapped (B)-ComBat (Da-ano et al 2020)).”
MethodRadiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421 · cited 1×
“…features (e.g. volume, shape, intensity, textural, etc) using high-throughput computing from medical images, such as for example magnetic resonance (MR), computed tomography (CT) or positron emission tomography (PET) (Lambin et al 2012, Kumar et al 2012, Gillies et al 2015, 2016, Laure et al 2017).”
MethodRadiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084 · cited 11×
“Initially, one way to address the variability of radiomic features associated with the diversity of scanner models, acquisition protocols and reconstruction algorithms and parameters when it comes to the aspect of multicenter data collection, is to standardize them, such as for example by following guidelines already…”
MethodInfluentialDecoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132 · cited 2×
“Finding intrinsic dependencies of radiomic features on number of voxels is exemplified by the fact that some of these features have been suggested as potential imaging biomarkers in recent studies (Cook et al 2013), (Yu et al 2009, Aerts et al 2014, Li et al 2017a).”
BackgroundResultFDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303 · cited 3×
“The study chose one reconstruction setting that is line with the standards provided by EARL (European Association of Nuclear Medicine (EANM) Research Ltd) (Boellaard et al 2015).”
BackgroundMethodModel-based analysis of oligonucleotide arrays: Expression index computation and outlier detection.
Li, C., & Wong, W. H. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.1.31 · Cited by 3,133 · cited 1×
“Variable-wise standardization transforms all variables to have a mean of 0 and a SD of 1, by subtracting the mean and dividing by the SD of every variable over all samples within a batch (Li and Wong 2001).”
MethodRadiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258 · cited 1×
“…features (e.g. volume, shape, intensity, textural, etc) using high-throughput computing from medical images, such as for example magnetic resonance (MR), computed tomography (CT) or positron emission tomography (PET) (Lambin et al 2012, Kumar et al 2012, Gillies et al 2015, 2016, Laure et al 2017).”
MethodTackling the widespread and critical impact of batch effects in high-throughput data
Leek, J. T., Scharpf, R. B., Bravo, H. C., Simcha, D., Langmead, B., Johnson, W. E., Geman, D., Baggerly, K., & Irizarry, R. A. (2010) · Nature Reviews Genetics · doi:10.1038/nrg2825 · Cited by 2,196 · cited 1×
“…of measurements that have qualitatively different behavior across conditions and are unrelated to the biological or scientific variables in a study (Leek et al 2010)’, ‘Systematic differences between the measurements of different batches of experiments (Luo et al 2010)’ or ‘Systematic…”
Background
Cited by
Scapicchio, C., Gabelloni, M., Barucci, A., Cioni, D., Saba, L., & Neri, E. (2021) · La radiologia medica · doi:10.1007/s11547-021-01389-x · Cited by 435
A review in radiomics: Making personalized medicine a reality via routine imaging
Guiot, J., Vaidyanathan, A., Deprez, L., Zerka, F., Danthine, D., Frix, A., Lambin, P., Bottari, F., Tsoutzidis, N., Miraglio, B., et al. (2022) · Medicinal Research Reviews · doi:10.1002/med.21846 · Cited by 337
Papadimitroulas, P., Brocki, L., Christopher Chung, N., Marchadour, W., Vermet, F., Gaubert, L., Eleftheriadis, V., Plachouris, D., Visvikis, D., Kagadis, G. C., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.009 · Cited by 226
“A large number of statistical methods have been proposed for statistical normalization [153].”
MethodSelf-citationShayesteh, S., Nazari, M., Salahshour, A., Sandoughdaran, S., Hajianfar, G., Khateri, M., Yaghobi Joybari, A., Jozian, F., Fatehi Feyzabad, S. H., Arabi, H., et al. (2021) · Medical Physics · doi:10.1002/mp.14896 · Cited by 70
Lu, L., Ahmed, F. S., Akin, O., Luk, L., Guo, X., Yang, H., Yoon, J., Hakimi, A. A., Schwartz, L. H., & Zhao, B. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.638185 · Cited by 31
Minimising multi-centre radiomics variability through image normalisation: a pilot study
Campello, V. M., Martín-Isla, C., Izquierdo, C., Guala, A., Palomares, J. F. R., Viladés, D., Descalzo, M. L., Karakas, M., Çavuş, E., Raisi-Estabragh, Z., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-16375-0 · Cited by 24
“A number of works have proposed harmonisation guidelines for computed tomography (CT) or positron emission tomography in multi-centre scenarios, while no guideline is available for magnetic resonance imaging (MRI), where the lack of a standard intensity grayscale – such as Hounsfield units in CT – poses further diffic…”
BackgroundExplainable artificial intelligence for multi-modal cancer analysis: from genomics to immunology
Zhang, M., & Yin, L. (2026) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2025.105040 · Cited by 5
Metadata
- Authors
- Da-Ano, R., Visvikis, D., & Hatt, M.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2020-12-02
- Volume
- 65
- Issue
- 24
- Pages
- 24TR02
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W3044994436
- Cited by
- 161
- References
- 90
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.