Detection of atrial fibrillation episodes using a wristband device
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Undiagnosed atrial fibrillation (AF) patients are at high risk of cardioembolic stroke or other complications. The aim of this study was to analyze the blood volume pulse (BVP) signals obtained from a wristband device and develop an algorithm for discriminating AF from normal sinus rhythm (NSR) or from other arrhythmias (ARR). APPROACH: Thirty patients with AF, 9 with ARR and 31 in NSR were included in the study. The recordings were obtained at rest from Empatica E4 wristband device and lasted 10 min. The analysis, on a 2 min segment, included spectral, variability and irregularity analysis performed on the inter-diastolic interval series, and similarity analysis performed on the BVP signal. Main results and Significance: Variability parameters were the highest in AF, the lowest in NSR and intermediate for ARR, as an example pNN50 values were, respectively, [Formula: see text], [Formula: see text], [Formula: see text] (p < 0.05). The similarity parameters were the highest in NSR, the lowest in AF and intermediate for ARR, as an example using a threshold for assessing similarity of [Formula: see text]: [Formula: see text], [Formula: see text], [Formula: see text], all p < 0.05. The rhythm classification was preceded by over-sampling (using synthetic minority over-sampling technique) the class of ARR, being it the smallest class. Then, the features selection was performed (using the sequential forward floating search algorithm) which identified two variability parameters (pNN70 and pNN40) as the best selection. The classification by the k-nearest neighbor classifier reached an accuracy of about 0.9 for NSR and AF, and 0.8 for ARR. Using pNN70 and pNN40, the specificity for the three rhythms was Spnsr = 0.928, Spaf = 0.963, Sparr = 0.768, while the sensitivity was Spnsr = 0.773, Spaf = 0.754, Sparr = 0.758.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880 · cited 2×
“Pattern Recognition Letters 15(1119-1125) (1994) [26] Richman, J.”
MethodHart, R. G., Pearce, L. A., & Aguilar, M. I. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-12-200706190-00007 · Cited by 4,793 · cited 2×
“IEEE Transactions on Biomedical Engineering 49(12), 1504–1513 (2002) [11] Hart, R.”
BackgroundSubclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100 · cited 2×
“Undiagnosed AF patients are at high risk of cardioembolic stroke or other complications and even an increased risk for death is associated to AF [28, 2, 12].”
BackgroundSassi, R., Cerutti, S., Lombardi, F., Malik, M., Huikuri, H. V., Peng, C.-K., Schmidt, G., Yamamoto, Y., Reviewers:, D., Gorenek, B., et al. (2015) · Europace · doi:10.1093/europace/euv015 · Cited by 727
Self-citationSposato, L. A., Cipriano, L. E., Saposnik, G., Vargas, E. R., Riccio, P. M., & Hachinski, V. (2015) · The Lancet Neurology · doi:10.1016/s1474-4422(15)70027-x · Cited by 694 · cited 2×
“JAMA Internal Medicine 174(1), 107–114 (2014) [29] Sposato, L.”
BackgroundPage, R. L., Wilkinson, W. E., Clair, W. K., McCarthy, E. A., & Pritchett, E. L. (1994) · Circulation · doi:10.1161/01.cir.89.1.224 · Cited by 627 · cited 2×
“Auton Neurosci 151, 147–53 (2009) [24] Page, R.”
BackgroundGil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
Self-citationSanders, P., Pürerfellner, H., Pokushalov, E., Sarkar, S., Di Bacco, M., Maus, B., & Dekker, L. R. C. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.03.005 · Cited by 162
Cited by
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
“The performance of techniques for detecting AF from the PPG has been assessed in several studies [76], [193]–[196] although further work is required to determine which approach is most suitable for clinical use [28].”
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
Wearables in cardiology: Here to stay
Dagher, L., Shi, H., Zhao, Y., & Marrouche, N. F. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.02.023 · Cited by 107
Mobile health applications for the detection of atrial fibrillation: a systematic review
Lopez Perales, C. R., Van Spall, H. G. C., Maeda, S., Jimenez, A., Laţcu, D. G., Milman, A., Kirakoya-Samadoulougou, F., Mamas, M. A., Muser, D., & Casado Arroyo, R. (2021) · EP Europace · doi:10.1093/europace/euaa139 · Cited by 77
“One of the case–control studies grouped participants into those with known sustained AF, those with other non-AF arrhythmias and those in sinus rhythm.(44) There were four studies of unclear design.”
Result
Metadata
- Authors
- Corino, V. D. A., Laureanti, R., Ferranti, L., Scarpini, G., Lombardi, F., & Mainardi, L. T.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2017-04-27
- Volume
- 38
- Issue
- 5
- Pages
- 787-799
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2584430982
- Cited by
- 96
- References
- 8
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of atrial fibrillation episodes using a wristband device. https://app.cochat.ai/papers/10.1088/1361-6579/aa5dd7
- The paper
- Corino, V. D. A., Laureanti, R., Ferranti, L., Scarpini, G., Lombardi, F., & Mainardi, L. T. (2017). Detection of atrial fibrillation episodes using a wristband device. Physiological Measurement. https://doi.org/10.1088/1361-6579/aa5dd7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.