Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions.
Open accessAbstract
In this paper we assessed the possibility of using the pulse rate variability (PRV) extracted from the photoplethysmography signal as an alternative measurement of the HRV signal in non-stationary conditions. The study is based on analysis of the changes observed during a tilt table test in the heart rate modulation of 17 young subjects. First, the classical indices of HRV analysis were compared to the indices from PRV in intervals where stationarity was assumed. Second, the time-varying spectral properties of both signals were compared by time-frequency (TF) and TF coherence analysis. Third, the effect of replacing PRV with HRV in the assessment of the changes of the autonomic modulation of the heart rate was considered. Time-invariant HRV and PRV indices showed no statistically significant differences (p > 0.05) and high correlation (>0.97). Time-frequency analysis revealed that the TF spectra of both signals were highly correlated (0.99 +/- 0.01); the difference between the instantaneous power, in the LF and HF bands, obtained from HRV and PRV was small (<10(-3) s(-2)) and their temporal patterns were highly correlated (0.98 +/- 0.04 and 0.95 +/- 0.06 in the LF and HF bands, respectively) and TF coherence in the LF and HF bands was high (0.97 +/- 0.04 and 0.89 +/- 0.08, respectively). Finally, the instantaneous power in the LF band was observed to significantly increase during head-up tilt by both HRV and PRV analysis. These results suggest that although some differences in the time-varying spectral indices extracted from HRV and PRV exist, mainly in the HF band associated with respiration, PRV could be used as a surrogate of HRV during non-stationary conditions, at least during the tilt table test.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Photoplethysmography is considered to represent an accurate approximation of the IBI.
“Photoplethysmography is considered to represent an accurate approximation of the IBI (Gil et al., 2010).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Gil et al., 2010
The Data and signal preprocessing section defines intervals between PPG pulses alongside ECG beat intervals, and the Conclusion reports strong agreement between variability measures derived from them. But the paper does not establish that PPG accurately approximates each individual interbeat interval: the Introduction and Limitations explain that pulse-transit-time variability and pulse-detection error create differences. (LLM, conf=0.84)
Experimental — accuracy not yet measuredTo characterize stress, arterial pulsewave signals are transformed into HRV, which represents the chronic stress level and an individual's stress vulnerability.
“To characterize stress, arterial pulsewave signals are transformed into HRV, which represents the chronic stress level and an individual’s stress vulnerability.98”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [98]
The stress signals of skin temperature, skin conductance, and pulsewave are dependent on the stimulation time and categorized into acute stress (response under 3 seconds stimulation) and chronic stress (response over 3 seconds stimulation).
“The stress signals of skin temperature, skin conductance, and pulsewave are dependent on the stimulation time and categorized in two types: acute stress (response under 3 seconds stimulation)11 and chronic stress (response over 3 seconds stimulation)39.”
From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [39]
For stress characterization, arterial pulsewave signals are required to be transformed into human heart rate variability (HRV).
“For stress characterization, the arterial pulsewave signals is required to be transformed into the human heart rate variability (HRV)39.”
From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [39]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159 · see citing works
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289 · see citing works
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130 · see citing works
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569 · see citing works
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martínez, J. P., Almeida, R., Olmos, S. C., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,606 · see citing works
Self-citationMontano, N., Ruscone, T. G., Porta, A., Lombardi, F., Pagani, M., & Malliani, A. (1994) · Circulation · doi:10.1161/01.cir.90.4.1826 · Cited by 1,108 · see citing works
Wigner-Ville spectral analysis of nonstationary processes
Martin, W., & Flandrin, P. (1985) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1985.1164760 · Cited by 554 · see citing works
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 455 · see citing works
Chen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425 · see citing works
Selvaraj, N., Jaryal, A. K., Santhosh, J., Deepak, K. K., & Anand, S. (2008) · Journal of Medical Engineering & Technology · doi:10.1080/03091900701781317 · Cited by 342 · see citing works
Lü, G., Yang, F., Taylor, J. A., & Stein, J. F. (2009) · Journal of Medical Engineering & Technology · doi:10.3109/03091900903150998 · Cited by 324 · see citing works
Pulse Oximetry: Theory and Applications for Noninvasive Monitoring
Mendelson, Y. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1601 · Cited by 320 · see citing works
Analysis of heart rate variability in the presence of ectopic beats using the heart timing signal
Mateo, J., & Laguna, P. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808831 · Cited by 287 · see citing works
Self-citationLu, S. F., Zhao, H., Ju, K., Shin, K., Lee, M., Shelley, K. H., & Chon, K. H. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9103-y · Cited by 284 · see citing works
Spectrophotometric monitoring of arterial oxygen saturation in the fingertip
Yoshiya, I., Shimada, Y., & Tanaka, K. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442476 · Cited by 262 · see citing works
Sampling frequency of the electrocardiogram for spectral analysis of the heart rate variability
Merri, M., Farden, D. C., Mottley, J. G., & Titlebaum, E. L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43621 · Cited by 248 · see citing works
Nitzan, M., Babchenko, A., Khanokh, B., & Landau, D. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/008 · Cited by 217 · see citing works
Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179 · see citing works
Pulse rate variability is not a surrogate for heart rate variability
Constant, I., Laude, D., Murat, I., & Elghozi, J. (1999) · Clinical Science · doi:10.1042/cs0970391 · Cited by 161 · see citing works
Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution
Yan, Y. S., Poon, C. C. Y., & Zhang, Y. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-3 · Cited by 157 · see citing works
Autonomic Control of Skin Microvessels: Assessment by Power Spectrum of Photoplethysmographic Waves
Bernardi, L., Radaelli, A., Soldà, P. L., Coats, A. J. S., REEDER, M. K., Calciati, A., Garrard, C. S., & Sleight, P. (1996) · Clinical Science · doi:10.1042/cs0900345 · Cited by 146 · see citing works
Jasson, S., Médigue, C., Maison‐Blanche, P., Montano, N., Meyer, L., Vermeiren, C., Pascale Mansier, A., Coumel, P., Malliani, A., & Bernard Swynghedauw, A. (1997) · Circulation · doi:10.1161/01.cir.96.10.3521 · Cited by 132 · see citing works
Pola, S., Macerata, A., Emdin, M., & Marchesi, C. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.477700 · Cited by 125 · see citing works
Cross spectral analysis of nonstationary processes
White, L. B., & Boashash, B. (1990) · IEEE Transactions on Information Theory · doi:10.1109/18.53742 · Cited by 124 · see citing works
A new method for pulse oximetry possessing inherent insensitivity to artifact
Hayes, M. J., & Smith, P. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.915711 · Cited by 122 · see citing works
陳, 文. (2001) · Medical Entomology and Zoology · Cited by 115 · see citing works
Naschitz, J. E., Bezobchuk, S., Priselac, R. M., Sundick, S., Dreyfuss, D., Khorshidi, I., Karidis, A., Manor, H., Nagar, M., Peck, E. R., et al. (2004) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-005-4300-z · Cited by 114 · see citing works
Orini, M., Bailón, R., Enk, R., Koelsch, S., Mainardi, L. T., & Laguna, P. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0592-3 · Cited by 108 · see citing works
Self-citationCardiovascular regulation in the period preceding vasovagal syncope in conscious humans
Julu, P. O. O., Cooper, V. L., Hansen, S. K., & HAINSWORTH, R. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.036715 · Cited by 104 · see citing works
Mainardi, L. T. (2008) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2008.0188 · Cited by 96 · see citing works
Self-citationCharlot, K., Cornolo, J., Brugniaux, J. V., Richalet, J., & Pichon, A. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/12/005 · Cited by 88 · see citing works
Gil, E., Vergara, J. M., & Laguna, P. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.12.002 · Cited by 88 · see citing works
Self-citationGil, E., Bailón, R., Vergara, J. M., & Laguna, P. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2037734 · Cited by 88 · see citing works
Self-citationPulse transit time as an indirect marker for variations in cardiovascular related reactivity
Foo, J. Y. A., & Lim, C. S. (2006) · Technology and Health Care · doi:10.3233/thc-2006-14205 · Cited by 83 · see citing works
Analysis of Heart Rate Variability Using Time-Varying Frequency Bands Based on Respiratory Frequency
Bailón, R., Laguna, P., Mainardi, L. T., et al. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353891 · Cited by 81 · see citing works
Self-citationGil, E., Mendez, M. O., Vergara, J. M., Cerutti, S., Bianchi, A. M., & Laguna, P. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2009340 · Cited by 80 · see citing works
Self-citationAssessment of pulse rate variability by the method of pulse frequency demodulation
Hayano, J., Barros, A. K., Kamiya, A., Ohte, N., & Yasuma, F. (2005) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-4-62 · Cited by 80 · see citing works
Limitations of Oximetry to Measure Heart Rate Variability Measures
Lü, G., & Yang, F. (2009) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-009-9082-3 · Cited by 65 · see citing works
Pulse rate variability is not a surrogate for heart rate variability
Constant, I., Laude, D., Murat, I., et al. (1999) · Clinical Science · doi:10.1042/cs19990062 · Cited by 58 · see citing works
Design of time-frequency representations using a multiform, tiltable exponential kernel
Costa, A. H., & Boudreaux-Bartels, G. F. (1995) · IEEE Transactions on Signal Processing · doi:10.1109/78.469860 · Cited by 54 · see citing works
Buchs, A. E., Slovik, Y., Rapoport, M. J., Rosenfeld, C., Khanokh, B., & Nitzan, M. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345963 · Cited by 51 · see citing works
Duality and classification of bilinear time-frequency signal representations
Hlawatsch, F. (1991) · IEEE Transactions on Signal Processing · doi:10.1109/78.134395 · Cited by 49 · see citing works
AKSELROD, S., Oz, O., Greenberg, M., & Keselbrener, L. (1997) · Journal of the Autonomic Nervous System · doi:10.1016/s0165-1838(97)00011-8 · Cited by 45 · see citing works
Sympathetically induced spontaneous fluctuations of the photoplethysmographic signal
Khanoka, B., Slovik, Y., Landau, D., & Nitzan, M. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351014 · Cited by 44 · see citing works
Ma, H. T., & Zhang, Y. (2006) · doi:10.1109/iembs.2006.259365 · Cited by 37 · see citing works
ECG artifact due to deep brain stimulation
Martin, W., Camenzind, E., & Burkhard, P. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13136-4 · Cited by 36 · see citing works
On arousal from sleep: time-frequency analysis
Mendez, M. O., Bianchi, A. M., Montano, N., Patruno, V., Gil, E., Mantaras, C., Aiolfi, S., & Cerutti, S. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0309-z · Cited by 34 · see citing works
Self-citationOrini, M., Bailón, R., Mainardi, L., et al. (2009) · Virtual Community of Pathological Anatomy (University of Castilla La Mancha) · Cited by 10 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- Bolanos M, Nazeran H and Haltiwanger E 2006 Comparison of heart rate variability signal features derived from electrocardiography and photoplethysmography in healthy individuals Engineering in Medicine and Biology Society. Proc. of the 28th Annu. Int. Conf. of the IEEE pp 4289-94
Cited by
Sorted by citations
Laborde, S., Mosley, E., & Thayer, J. F. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.00213 · Cited by 2,336 · see citing works
“Several recording techniques exist to measure HRV either through ECG recordings, the IBI or photoplethysmography.”
MethodInfluentialOn the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · see citing works
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661 · see citing works
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542 · see citing works
Wearable sensors for monitoring the physiological and biochemical profile of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0150-9 · Cited by 537 · see citing works
Zhang, Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406332 · Cited by 388 · see citing works
Advances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292 · see citing works
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250 · see citing works
Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review
Georgiou, K., Larentzakis, A. V., Khamis, N. N., Alsuhaibani, G. I., Alaska, Y. A., & Giallafos, E. J. (2018) · Folia Medica · doi:10.2478/folmed-2018-0012 · Cited by 244 · see citing works
A Flexible and Wearable Human Stress Monitoring Patch
Yoon, S., Sim, J. K., & Cho, Y.-H. (2016) · Scientific Reports · doi:10.1038/srep23468 · Cited by 151 · see citing works
Arza, A., Garzón-Rey, J. M., Lázaro, J., Gil, E., Lopez-Anton, R., de la Camara, C., Laguna, P., Bailon, R., & Aguiló, J. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-018-1879-z · Cited by 148 · see citing works
Self-citationChow, H.-W., & Yang, C.-C. (2020) · JMIR mHealth and uHealth · doi:10.2196/14707 · Cited by 140 · see citing works
“However, the accuracy might vary across brands [16,31] in terms of activity patterns or speed, exercise intensities [10,14,31], skin tone [10], room temperature [32], placement of sensors [29], or compression-induced and motion-induced artifacts [13,32-34].”
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138 · see citing works
Choi, A., & Shin, H. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa5efa · Cited by 116 · see citing works
An Ultra Low Power Personalizable Wrist Worn ECG Monitor Integrated With IoT Infrastructure
Beach, C., Krachunov, S., Pope, J., Fafoutis, X., Piechocki, R. J., Craddock, I., & Casson, A. J. (2018) · IEEE Access · doi:10.1109/access.2018.2864675 · Cited by 91 · see citing works
Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise
HORTON, J. F., STERGIOU, P., FUNG, T. S., & KATZ, L. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001388 · Cited by 79 · see citing works
Reduced heart rate variability in schizophrenia and bipolar disorder compared to healthy controls
Quintana, D. S., Westlye, L. T., Kaufmann, T., Rustan, Ø. G., Brandt, C. L., Haatveit, B., Steen, N. E., & Andreassen, O. A. (2016) · Acta Psychiatrica Scandinavica · doi:10.1111/acps.12498 · Cited by 73 · see citing works
Scardulla, F., D’Acquisto, L., Colombarini, R., Hu, S., Pasta, S., & Bellavia, D. (2020) · Sensors · doi:10.3390/s20185052 · Cited by 72 · see citing works
Siddi, S., Bailon, R., Giné-Vázquez, I., Matcham, F., Lamers, F., Kontaxis, S., Laporta, E., Garcia, E., Lombardini, F., Annas, P., et al. (2023) · Psychological Medicine · doi:10.1017/s0033291723001034 · Cited by 31 · see citing works
Real-Time Quality Index to Control Data Loss in Real-Life Cardiac Monitoring Applications
Vila, G., Godin, C., Charbonnier, S., & Campagne, A. (2021) · Sensors · doi:10.3390/s21165357 · Cited by 8 · see citing works
- Authors
- Gil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P.
- Affiliations
- Universidad de Zaragoza (ES)
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (ES)
- Politecnico di Milano (IT)
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-08-11
- Volume
- 31
- Issue
- 9
- Pages
- 1271-1290
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2010524207
- Cited by
- 461
- References
- 49
- Citations by year
- 2026: 14 · 2025: 21 · 2024: 26 · 2023: 42 · 2022: 44 · 2021: 36 · 2020: 42 · 2019: 44 · 2018: 39 · 2017: 38 · 2016: 28 · 2015: 36 · 2014: 15 · 2013: 13 · 2012: 13
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Virtual Community of Pathological Anatomy (University of Castilla La Mancha) (submittedVersion)
- Funders
- Ministerio de Ciencia y Tecnología
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- photoplethysmography, pulse rate variability, heart rate variability, non-stationary signals, tilt table test, time-frequency analysis, time-frequency coherence, respiration, surrogate measurement
- MeSH terms
- Autonomic Nervous System, Female, Heart Rate, Humans, Male, Time Factors, Photoplethysmography, Tilt-Table Test
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review