The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Classification of 12-lead ECGs: the PhysioNet/Computing in Cardiology Challenge 2020
Open accessAbstract
Objective : Vast 12-lead ECGs repositories provide opportunities to develop new machine learning approaches for creating accurate and automatic diagnostic systems for cardiac abnormalities. However, most 12-lead ECG classification studies are trained, tested, or developed in single, small, or relatively homogeneous datasets. In addition, most algorithms focus on identifying small numbers of cardiac arrhythmias that do not represent the complexity and difficulty of ECG interpretation. This work addresses these issues by providing a standard, multi-institutional database and a novel scoring metric through a public competition: the PhysioNet/Computing in Cardiology Challenge 2020. Approach : A total of 66 361 12-lead ECG recordings were sourced from six hospital systems from four countries across three continents; 43 101 recordings were posted publicly with a focus on 27 diagnoses. For the first time in a public competition, we required teams to publish open-source code for both training and testing their algorithms, ensuring full scientific reproducibility. Main results : A total of 217 teams submitted 1395 algorithms during the Challenge, representing a diversity of approaches for identifying cardiac abnormalities from both academia and industry. As with previous Challenges, high-performing algorithms exhibited significant drops ( ≲ 10%) in performance on the hidden test data. Significance : Data from diverse institutions allowed us to assess algorithmic generalizability. A novel evaluation metric considered different misclassification errors for different cardiac abnormalities, capturing the outcomes and risks of different diagnoses. Requiring both trained models and code for training models improved the generalizability of submissions, setting a new bar in reproducibility for public data science competitions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Heart Disease and Stroke Statistics—2019 Update: A Report From the American Heart Association
Benjamin, E. J., Muntner, P., Alonso, A., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Das, S. R., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000659 · Cited by 9,036
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Tarver, T. (2014) · Journal of Consumer Health On the Internet · doi:10.1080/15398285.2014.902284 · Cited by 5,605
AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram
Surawicz, B., Childers, R., Deal, B. J., & Gettes, L. S. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.12.013 · Cited by 2,032
PTB-XL, a large publicly available electrocardiography dataset
Wagner, P., Strodthoff, N., Bousseljot, R.-D., Kreiseler, D., Lunze, F. I., Samek, W., & Schaeffter, T. (2020) · Scientific Data · doi:10.1038/s41597-020-0495-6 · Cited by 1,315
Automatic diagnosis of the 12-lead ECG using a deep neural network
Ribeiro, A. H., Ribeiro, M. H., Paixão, G. M. M., Oliveira, D. M., Gomes, P. R., Canazart, J. A., Ferreira, M. P. S., Andersson, C. R., Macfarlane, P. W., Meira, W., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15432-4 · Cited by 894
Recommendations for the Standardization and Interpretation of the Electrocardiogram
Kligfield, P., Gettes, L. S., Bailey, J. J., Childers, R., Deal, B. J., Hancock, E. W., van Herpen, G., Kors, J. A., Macfarlane, P., Mirvis, D. M., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.024 · Cited by 807
Kligfield (2007) · doi:10.1161/circulationaha.106.180200 · Cited by 802
Ribeiro, A. H., Ribeiro, M. H., Paixao, G. M., Oliveira, D. M., Gomes, P. R., Canazart, J. A., Ferreira, M. P. S., Andersson, C. R., Macfarlane, P. W., Meira, W., et al. (2020) · RePEc: Research Papers in Economics · doi:10.5281/zenodo.3625006 · Cited by 715
Cited by
MLCM: Multi-Label Confusion Matrix
(2022) · doi:10.1109/access.2022.3151048 · Cited by 447
Self-Supervised Contrastive Learning for Medical Time Series: A Systematic Review
Liu, Z., Alavi, A., Li, M., & Zhang, X. (2023) · Sensors · doi:10.3390/s23094221 · Cited by 90
Applications of Self-Supervised Learning to Biomedical Signals: A Survey
Pup, F. D., & Atzori, M. (2023) · IEEE Access · doi:10.1109/access.2023.3344531 · Cited by 43
Mehari, T., & Strodthoff, N. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3310989 · Cited by 29
Metadata
- Authors
- Perez Alday, E. A., Gu, A., J Shah, A., Robichaux, C., Ian Wong, A.-K., Liu, C., Liu, F., Bahrami Rad, A., Elola, A., Seyedi, S., Li, Q., Sharma, A., Clifford, G. D., & Reyna, M. A.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2020-12-01
- Volume
- 41
- Issue
- 12
- Pages
- 124003
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W3098699929
- Cited by
- 436
- References
- 22
- FWCI
- 39.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Classification of 12-lead ECGs: the PhysioNet/Computing in Cardiology Challenge 2020. https://app.cochat.ai/papers/10.1088/1361-6579/abc960
- The paper
- Perez Alday, E. A., Gu, A., J Shah, A., Robichaux, C., Ian Wong, A.-K., Liu, C., Liu, F., Bahrami Rad, A., Elola, A., Seyedi, S., Li, Q., Sharma, A., Clifford, G. D., & Reyna, M. A. (2020). Classification of 12-lead ECGs: the PhysioNet/Computing in Cardiology Challenge 2020. Physiological Measurement. https://doi.org/10.1088/1361-6579/abc960
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.