Chemical and physical side effects at application of ultrashort laser pulses for intrastromal refractive surgery
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Focusing femtosecond (fs) laser pulses into transparent media, such as corneal tissue, leads to optical breakdown, generation of a micro-plasma and, thus, a cutting effect inside the tissue - provided the intensity at the focus exceeds a threshold which depends on the pulse duration. For fs pulses, the corresponding threshold pulse energy is reduced by some orders of magnitude compared with ns or ps pulses. At a low pulse energy, thermal and mechanical damage to surrounding tissue is minimized, enabling a highly precise cutting effect inside the tissue while leaving anterior layers unaltered. In the following, investigations concerning aspects of the interaction of ultrashort laser pulses with aqueous media are presented: in particular, detection of pressure transients and bubble formation. For the first time - to our knowledge - the content of the resulting gas bubbles was analysed by gas chromatography, giving evidence of molecular hydrogen. Secondly, the potential of three-dimensional cutting effects within the corneal stroma for refractive surgery applications was evaluated in vitro on freshly enucleated porcine eyeglobes. Laser pulses with a duration of 200-300 fs and energies of 1.5-600 µJ were provided by a mode-locked Ti:sapphire laser with subsequent chirped pulse amplification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Femtosecond, picosecond and nanosecond laser ablation of solids
Chichkov, B. N., Momma, C., Nolte, S., Alvensleben, F., & Tünnermann, A. (1996) · Applied Physics A Materials Science & Processing · doi:10.1007/bf01567637 · Cited by 3,066
Shielding properties of laser-induced breakdown in water for pulse durations from 5 ns to 125 fs
Hammer, D. X., Jansen, E. D., Frenz, M., Noojin, G. D., Thomas, R. J., Noack, J., Vogel, A., Rockwell, B. A., & Welch, A. J. (1997) · Applied Optics · doi:10.1364/ao.36.005630 · Cited by 97
Cited by
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
Laser Synthesis and Processing of Colloids: Fundamentals and Applications
Zhang, D., Gökce, B., & Barcikowski, S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00468 · Cited by 1,344
Self-citationNishimura, N., Schaffer, C. B., Friedman, B., Tsai, P. S., Lyden, P. D., & Kleinfeld, D. (2006) · Nature Methods · doi:10.1038/nmeth844 · Cited by 308
Surgical applications of femtosecond lasers
Chung, S. H., & Mazur, E. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910053 · Cited by 281
Femtosecond laser-induced formation of submicrometer spikes on silicon in water
Shen, M. Y., Crouch, C. H., Carey, J. E., & Mazur, E. (2004) · Applied Physics Letters · doi:10.1063/1.1828575 · Cited by 261
Metadata
- Authors
- Maatz, G., Heisterkamp, A., Lubatschowski, H., Barcikowski, S., Fallnich, C., Welling, H., & Ertmer, W.
- Venue
- Journal of Optics A: Pure and Applied Optics
- Publisher
- IOP Publishing
- Published
- 1999-12-21
- Volume
- 2
- Issue
- 1
- Pages
- 59-64
- ISSN
- 1464-4258 (ISSN-L)
- 1741-3567
- OpenAlex
- W2152342099
- Cited by
- 83
- References
- 2
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chemical and physical side effects at application of ultrashort laser pulses for intrastromal refractive surgery. https://app.cochat.ai/papers/10.1088/1464-4258/2/1/311
- The paper
- Maatz, G., Heisterkamp, A., Lubatschowski, H., Barcikowski, S., Fallnich, C., Welling, H., & Ertmer, W. (2000). Chemical and physical side effects at application of ultrashort laser pulses for intrastromal refractive surgery. Journal of Optics A: Pure and Applied Optics. https://doi.org/10.1088/1464-4258/2/1/311
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.