Optical biosensor microsystems based on the integration of highly sensitive Mach–Zehnder interferometer devices
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
We present highly sensitive optical biosensors able to be fully integrated in lab-on-a-chip microsystems using standard CMOS compatible processes. These optical biosensors are based on integrated Mach–Zehnder interferometers, which have been designed to have high surface sensitivity and monomode behaviour. As a biosensing application of the devices we show the real-time detection of the covalent immobilization and hybridization of DNA strands without labelling. In order to achieve a lab-on-a-chip portable microsystem, we present the integration of the sensor with a CMOS compatible microfluidic system using SU-8 photolithography patterned layers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface plasmon resonance sensors: review
Homola, J., Yee, S. S., & Gauglitz, G. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00321-9 · Cited by 5,453 · cited 1×
“…sensors can show variations depending on the method used for exciting the surface plasmon (prism coupling, grating coupling, optical fibres . . . ) [ 1, 2], but can be set in the order of 10 − 5 in bulk refractive index changes, which corresponds to a limit of detection of 1–5 pg mm − 2 of…”
MethodColloidal Au-Enhanced Surface Plasmon Resonance for Ultrasensitive Detection of DNA Hybridization
He, L., Musick, M. D., Nicewarner, S. R., Salinas, F. G., Benkovic, S. J., Natan, M. J., & Keating, C. D. (2000) · Journal of the American Chemical Society · doi:10.1021/ja001215b · Cited by 932 · cited 1×
“In order to improve such a limit of detection, labelling of the DNA complementary sequence with colloidal gold nanoparticles has been proposed, reaching a 1000-fold reduction in the limit of detection [17].”
BackgroundGuided-Wave Optoelectronics: Device Characterization, Analysis, and Design
(1995) · Springer eBooks · doi:10.1007/978-1-4899-1039-4 · Cited by 446
Heideman, R. G., & Lambeck, P. V. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00283-x · Cited by 331
Blanco, F. J., Agirregabiria, M., Garcia, J., Berganzo, J., Tijero, M., Arroyo, M. T., Ruano, J. M., Aramburu, I., & Mayora, K. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/7/027 · Cited by 170
Self-citationDetection of TP53 mutation using a portable surface plasmon resonance DNA-based biosensor
Jiang, T., Minunni, M., Wilson, P., Zhang, J., Turner, A. P. F., & Mascini, M. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.08.040 · Cited by 93
Detection of PCR Products in Solution Using Surface Plasmon Resonance
Kai, E., Sawata, S. Y., Ikebukuro, K., Iida, T., Honda, T., & Karube, I. (1999) · Analytical Chemistry · doi:10.1021/ac9807161 · Cited by 92 · cited 1×
“So far, most of the studies related to the detection of DNA hybridizations with optical biosensors have been performed using SPR biosensors [14–16].”
BackgroundHydrothermal synthesis of ceramic nanomaterials for functional applications
Piticescu, R. M., Piticescu, R. R., Taloi, D., & Badilita, V. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/2/341 · Cited by 64
Cited by
Plasmonic Biosensing: Focus Review
Mejía-Salazar, J. R., & Oliveira, O. N. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00359 · Cited by 544
Silicon Photonic Biosensors Using Label-Free Detection
Luan, E., Shoman, H., Ratner, D. M., Cheung, K. C., & Chrostowski, L. (2018) · Sensors · doi:10.3390/s18103519 · Cited by 379
Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
Highly sensitive Mach–Zehnder interferometer biosensor based on silicon nitride slot waveguide
Liu, Q., Tu, X., Kim, K. W., Kee, J. S., Shin, Y., Han, K., Yoon, Y.-J., Lo, G.-Q., & Park, M. K. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.07.053 · Cited by 253
Silicon photonic wire biosensor array for multiplexed real-time and label-free molecular detection
Densmore, A., Vachon, M., Xu, D.-X., Janz, S., Ma, R., Li, Y.-H., Lopinski, G., Delâge, A., Lapointe, J., Luebbert, C. C., et al. (2009) · Optics Letters · doi:10.1364/ol.34.003598 · Cited by 203
Metadata
- Authors
- Sepúlveda, B., Río, J. S. D., Moreno, M., Blanco, F. J., Mayora, K., Domínguez, C., & Lechuga, L. M.
- Venue
- Journal of Optics A: Pure and Applied Optics
- Publisher
- IOP Publishing
- Published
- 2006-06-12
- Volume
- 8
- Issue
- 7
- Pages
- S561-S566
- ISSN
- 1464-4258 (ISSN-L)
- 1741-3567
- OpenAlex
- W1989242806
- Cited by
- 188
- References
- 8
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.