The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Effects of surface coating on reducing friction and wear of orthopaedic implants
Open accessAbstract
Coatings such as diamond-like carbon (DLC) and titanium nitride (TiN) are employed in joint implants due to their excellent tribological properties. Recently, graphite-like carbon (GLC) and tantalum (Ta) have been proven to have good potential as coating as they possess mechanical properties similar to bones-high hardness and high flexibility. The purpose of this systematic literature review is to summarize the coating techniques of these four materials in order to compare their mechanical properties and tribological outcomes. Eighteen studies published between January 2000 and February 2013 have met the inclusion criteria for this review. Details of their fabrication parameters, material and mechanical properties along with the tribological outcomes, such as friction and wear rate, were identified and are presented in a systematic way. Although experiment conditions varied, we conclude that Ta has the lowest wear rate compared to DLC, GLC and TiN because it has a lower wear rate with high contact pressure as well as higher hardness to elasticity ratio. However, a further tribology test is needed in an environment which replicates artificial joints to confirm the acceptability of these findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Leyland, A., & Matthews, A. (2000) · Wear · doi:10.1016/s0043-1648(00)00488-9 · Cited by 3,103
Chemical vapour deposition of coatings
Choy, K. (2003) · Progress in Materials Science · doi:10.1016/s0079-6425(01)00009-3 · Cited by 1,655
Raman spectroscopy of hydrogenated amorphous carbons
Casiraghi, C., Ferrari, A. C., & Robertson, J. (2005) · Physical Review B · doi:10.1103/physrevb.72.085401 · Cited by 1,335
Biomedical applications of titanium and its alloys
Elias, C. N., Lima, J. H. C., Valiev, R., & Meyers, M. A. (2008) · JOM · doi:10.1007/s11837-008-0031-1 · Cited by 983
ELECTROPHORETIC DEPOSITION OF MATERIALS
Van der Biest, O. O., & Vandeperre, L. J. (1999) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.29.1.327 · Cited by 782
A review of modified DLC coatings for biological applications
Hauert, R. (2003) · Diamond and Related Materials · doi:10.1016/s0925-9635(03)00081-5 · Cited by 681
A study of the wear mechanism of diamond-like carbon films
Liu, Y., Erdemir, A., & Meletis, E. I. (1996) · Surface and Coatings Technology · doi:10.1016/0257-8972(95)02623-1 · Cited by 586
Balla, V. K., Bodhak, S., Bose, S., & Bandyopadhyay, A. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.01.046 · Cited by 504
Tensegrity, cellular biophysics, and the mechanics of living systems
Ingber, D. E., Wang, N., & Stamenović, D. (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/4/046603 · Cited by 485
A biologically effective fullerene (C60) derivative with superoxide dismutase mimetic properties
Ali, S. S., Hardt, J. I., Quick, K. L., Sook Kim-Han, J., Erlanger, B. F., Huang, T.-T., Epstein, C. J., & Dugan, L. L. (2004) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2004.07.002 · Cited by 400
Cited by
Bone biomaterials and interactions with stem cells
Gao, C., Peng, S., Feng, P., & Shuai, C. (2017) · Bone Research · doi:10.1038/boneres.2017.59 · Cited by 720
Tissue Engineering and Cell-Based Therapies for Fractures and Bone Defects
Perez, J. R., Kouroupis, D., Li, D. J., Best, T. M., Kaplan, L., & Correa, D. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00105 · Cited by 390
Bioinspired surface modification of orthopedic implants for bone tissue engineering
Hu, C., Ashok, D., Nisbet, D. R., & Gautam, V. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119366 · Cited by 324
Functionally graded materials for orthopedic applications – an update on design and manufacturing
Sola, A., Bellucci, D., & Cannillo, V. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.12.013 · Cited by 314
Recent advances in nano scaffolds for bone repair
Yi, H., Ur Rehman, F., Zhao, C., Liu, B., & He, N. (2016) · Bone Research · doi:10.1038/boneres.2016.50 · Cited by 266
Metadata
- Authors
- Ching, H. A., Choudhury, D., Nine, M. J., & Abu Osman, N. A.
- Venue
- Science and Technology of Advanced Materials
- Publisher
- Informa UK Limited
- Published
- 2014-02
- Volume
- 15
- Issue
- 1
- Pages
- 014402
- ISSN
- 1468-6996 (ISSN-L)
- 1878-5514
- OpenAlex
- W2106983975
- Cited by
- 292
- References
- 33
- FWCI
- 19.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of surface coating on reducing friction and wear of orthopaedic implants. https://app.cochat.ai/papers/10.1088/1468-6996/15/1/014402
- The paper
- Ching, H. A., Choudhury, D., Nine, M. J., & Abu Osman, N. A. (2014). Effects of surface coating on reducing friction and wear of orthopaedic implants. Science and Technology of Advanced Materials. https://doi.org/10.1088/1468-6996/15/1/014402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.