Tracking single particles: a user-friendly quantitative evaluation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
As our knowledge of biological processes advances, we are increasingly aware that cells actively position sub-cellular organelles and other constituents to control a wide range of biological processes. Many studies quantify the position and motion of, for example, fluorescently labeled proteins, protein aggregates, mRNA particles or virus particles. Both differential interference contrast (DIC) and fluorescence microscopy can visualize vesicles, nuclei or other small organelles moving inside cells. While such studies are increasingly important, there has been no complete analysis of the different tracking methods in use, especially from the practical point of view. Here we investigate these methods and clarify how well different algorithms work and also which factors play a role in assessing how accurately the position of an object can be determined. Specifically, we consider how ultimate performance is affected by magnification, by camera type (analog versus digital), by recording medium (VHS and SVHS tape versus direct tracking from camera), by image compression, by type of imaging used (fluorescence versus DIC images) and by a variety of sources of noise. We show that most methods are capable of nanometer scale accuracy under realistic conditions; tracking accuracy decreases with increasing noise. Surprisingly, accuracy is found to be insensitive to the numerical aperture, but, as expected, it scales with magnification, with higher magnification yielding improved accuracy (within limits of signal-to-noise). When noise is present at reasonable levels, the effect of image compression is in most cases small. Finally, we provide a free, robust implementation of a tracking algorithm that is easily downloaded and installed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yildiz, A., Tomishige, M., Vale, R. D., & Selvin, P. R. (2004) · Science · doi:10.1126/science.1093753 · Cited by 965
Inoué, S., & Spring, K. R. (1997) · doi:10.1007/978-1-4615-5859-0 · Cited by 326
Cited by
Methods for Cell and Particle Tracking
Meijering, E., Dzyubachyk, O., & Smal, I. (2012) · Methods in Enzymology · doi:10.1016/b978-0-12-391857-4.00009-4 · Cited by 1,400
Objective comparison of particle tracking methods
Chenouard, N., Smal, I., de Chaumont, F., Maška, M., Sbalzarini, I. F., Gong, Y., Cardinale, J., Carthel, C., Coraluppi, S., Winter, M., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2808 · Cited by 894
Single Particle Tracking: From Theory to Biophysical Applications
Shen, H., Tauzin, L. J., Baiyasi, R., Wang, W., Moringo, N., Shuang, B., & Landes, C. F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00815 · Cited by 536
Multiple-motor based transport and its regulation by Tau
Vershinin, M., Carter, B. C., Razafsky, D. S., King, S. J., & Gross, S. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607919104 · Cited by 457
Self-citationConsequences of Motor Copy Number on the Intracellular Transport of Kinesin-1-Driven Lipid Droplets
Shubeita, G. T., Tran, S. L., Xu, J., Vershinin, M., Cermelli, S., Cotton, S. L., Welte, M. A., & Gross, S. P. (2008) · Cell · doi:10.1016/j.cell.2008.10.021 · Cited by 365
Self-citationSoppina, V., Rai, A. K., Ramaiya, A. J., Barak, P., & Mallik, R. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0906524106 · Cited by 349
“Motion of single endosomes was tracked offline (37) with subpixel resolution ( 5 nm) by calculating the centroid of a cross-correlation image and analyzed as described (18, 22, 25).”
MethodLIS1 and NudE Induce a Persistent Dynein Force-Producing State
McKenney, R. J., Vershinin, M., Kunwar, A., Vallee, R. B., & Gross, S. P. (2010) · Cell · doi:10.1016/j.cell.2010.02.035 · Cited by 349
Self-citationMolecular Adaptations Allow Dynein to Generate Large Collective Forces inside Cells
Rai, A. K., Rai, A., Ramaiya, A. J., Jha, R., & Mallik, R. (2013) · Cell · doi:10.1016/j.cell.2012.11.044 · Cited by 284
Advanced Level-Set-Based Cell Tracking in Time-Lapse Fluorescence Microscopy
Dzyubachyk, O., van Cappellen, W. A., Essers, J., Niessen, W. J., & Meijering, E. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2038693 · Cited by 255
Quantitative Comparison of Spot Detection Methods in Fluorescence Microscopy
Smal, I., Loog, M., Niessen, W., & Meijering, E. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2025127 · Cited by 255
Tracking in cell and developmental biology
Meijering, E., Dzyubachyk, O., Smal, I., & van Cappellen, W. A. (2009) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2009.07.004 · Cited by 242
“The simplest approach to particle detection is to first identify (potential) particle loci by applying intensity thresholding and then to estimate their positions by computing the centroid (center of intensity mass) for each locus [62].”
BackgroundGallego-Urrea, J. A., Tuoriniemi, J., & Hassellöv, M. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.01.005 · Cited by 226
Single-Virus Tracking: From Imaging Methodologies to Virological Applications
Liu, S.-L., Wang, Z.-G., Xie, H.-Y., Liu, A.-A., Lamb, D. C., & Pang, D.-W. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00692 · Cited by 224
Building Complexity: An In Vitro Study of Cytoplasmic Dynein with In Vivo Implications
Mallik, R., Petrov, D., Lex, S. A., King, S. J., & Gross, S. P. (2005) · Current Biology · doi:10.1016/j.cub.2005.10.039 · Cited by 201
“The standard deviation in the position of a fixed bead was found to be approximately 3 nm. Verification of sub-pixel resolution and details of performance of the video-tracking routine have been reported elsewhere [ 35 ].”
Self-citationControl of cell membrane tension by myosin-I
Nambiar, R., McConnell, R. E., & Tyska, M. J. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0901641106 · Cited by 188
“Forces exerted by membrane tethers on the bead were derived from microsphere position data (15), acquired at video rate using a CCD camera; position data were converted to force using the stiffness of the optical trap (kTrap), which for our studies ranged from 0.”
MethodSmal, I., Draegestein, K., Galjart, N., Niessen, W., & Meijering, E. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.916964 · Cited by 181
“are applicable to image data showing limited numbers of clearly distinguishable spots against relatively uniform backgrounds, but fail to yield reliable results in the case of poor imaging conditions [12], [13].”
BackgroundMethodInfluentialA cytoplasmic dynein tail mutation impairs motor processivity
Ori-McKenney, K. M., Xu, J., Gross, S. P., & Vallee, R. B. (2010) · Nature Cell Biology · doi:10.1038/ncb2127 · Cited by 165
“Optical-trap assays, data recording, particle tracking and stalling-force analysis were performed as previously describe”
MethodSelf-citation
Metadata
- Authors
- Carter, B. C., Shubeita, G. T., & Gross, S. P.
- Venue
- Physical Biology
- Publisher
- IOP Publishing
- Published
- 2005-03
- Volume
- 2
- Issue
- 1
- Pages
- 60-72
- ISSN
- 1478-3967 (ISSN-L)
- 1478-3975
- OpenAlex
- W2116928225
- Cited by
- 152
- References
- 2
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.