The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Advanced Level-Set-Based Cell Tracking in Time-Lapse Fluorescence Microscopy
Abstract
Cell segmentation and tracking in time-lapse fluorescence microscopy images is a task of fundamental importance in many biological studies on cell migration and proliferation. In recent years, level sets have been shown to provide a very appropriate framework for this purpose, as they are well suited to capture topological changes occurring during mitosis, and they easily extend to higher dimensional image data. This model evolution approach has also been extended to deal with many cells concurrently. Notwithstanding its high potential, the multiple-level-set method suffers from a number of shortcomings, which limit its applicability to a larger variety of cell biological imaging studies. In this paper, we propose several modifications and extensions to the coupled-active-surfaces algorithm, which considerably improve its robustness and applicability. Our algorithm was validated by comparing it to the original algorithm and two other cell segmentation algorithms. For the evaluation, four real fluorescence microscopy image datasets were used, involving different cell types and labelings that are representative of a large range of biological experiments. Improved tracking performance in terms of precision (up to 11%), recall (up to 8%), ability to correctly capture all cell division events, and computation time (up to nine times reduction) is achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Chan, T. F., & Vese, L. A. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.902291 · Cited by 10,304
CellProfiler: image analysis software for identifying and quantifying cell phenotypes
Carpenter, A. E., Jones, T. R., Lamprecht, M. R., Clarke, C., Kang, I. H., Friman, O., Guertin, D. A., Chang, J. H., Lindquist, R. A., Moffat, J., et al. (2006) · Genome Biology · doi:10.1186/gb-2006-7-10-r100 · Cited by 5,157
Level Set Methods and Dynamic Implicit Surfaces
Osher, S., & Fedkiw, R. (2003) · Applied Mathematical Sciences · doi:10.1007/b98879 · Cited by 4,951
Survey over image thresholding techniques and quantitative performance evaluation
Sankur, B. (2004) · Journal of Electronic Imaging · doi:10.1117/1.1631315 · Cited by 4,583
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Byrt, T., Bishop, J., & Carlin, J. B. (1993) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(93)90018-v · Cited by 2,179 · cited 1×
“This was done by using a similar measure to the bias index [ 68 ], which is the measure that is commonly used in epidemiology.”
MethodWarfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,072
Handbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Cited by
An objective comparison of cell-tracking algorithms
Ulman, V., Maška, M., Magnusson, K. E. G., Ronneberger, O., Haubold, C., Harder, N., Matula, P., Matula, P., Svoboda, D., Radojevic, M., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4473 · Cited by 565
Self-citationCell Segmentation: 50 Years Down the Road [Life Sciences]
Meijering, E. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2204190 · Cited by 472
Self-citationA benchmark for comparison of cell tracking algorithms
Maška, M., Ulman, V., Svoboda, D., Matula, P., Matula, P., Ederra, C., Urbiola, A., España, T., Venkatesan, S., Balak, D. M. W., et al. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu080 · Cited by 415
Self-citationAn Automatic Learning-Based Framework for Robust Nucleus Segmentation
Xing, F., Xie, Y., & Yang, L. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2481436 · Cited by 351
Image processing and classification algorithm for yeast cell morphology in a microfluidic chip
Yang Yu, B., Elbuken, C., Ren, C. L., & Huissoon, J. P. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3589100 · Cited by 349
Metadata
- Authors
- Dzyubachyk, O., van Cappellen, W. A., Essers, J., Niessen, W. J., & Meijering, E.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-03
- Volume
- 29
- Issue
- 3
- Pages
- 852-867
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2100138660
- Cited by
- 255
- References
- 54
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advanced Level-Set-Based Cell Tracking in Time-Lapse Fluorescence Microscopy. https://app.cochat.ai/papers/10.1109/tmi.2009.2038693
- The paper
- Dzyubachyk, O., van Cappellen, W. A., Essers, J., Niessen, W. J., & Meijering, E. (2010). Advanced Level-Set-Based Cell Tracking in Time-Lapse Fluorescence Microscopy. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2009.2038693
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.