Adaptive deep brain stimulation for Parkinson’s disease using motor cortex sensing
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Contemporary deep brain stimulation (DBS) for Parkinson's disease is delivered continuously, and adjustments based on patient's changing symptoms must be made manually by a trained clinician. Patients may be subjected to energy intensive settings at times when they are not needed, possibly resulting in stimulation-induced adverse effects, such as dyskinesia. One solution is 'adaptive' DBS, in which stimulation is modified in real time based on neural signals that co-vary with the severity of motor signs or of stimulation-induced adverse effects. Here we show the feasibility of adaptive DBS using a fully implanted neural prosthesis. APPROACH: We demonstrate adaptive deep brain stimulation in two patients with Parkinson's disease using a fully implanted neural prosthesis that is enabled to utilize brain sensing to control stimulation amplitude (Activa PC + S). We used a cortical narrowband gamma (60-90 Hz) oscillation related to dyskinesia to decrease stimulation voltage when gamma oscillatory activity is high (indicating dyskinesia) and increase stimulation voltage when it is low. MAIN RESULTS: We demonstrate the feasibility of 'adaptive deep brain stimulation' in two patients with Parkinson's disease. In short term in-clinic testing, energy savings were substantial (38%-45%), and therapeutic efficacy was maintained. SIGNIFICANCE: This is the first demonstration of adaptive DBS in Parkinson's disease using a fully implanted device and neural sensing. Our approach is distinct from other strategies utilizing basal ganglia signals for feedback control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
A Randomized Trial of Deep-Brain Stimulation for Parkinson's Disease
Deuschl, G., Schade-Brittinger, C., Krack, P., Volkmann, J., Schäfer, H., Bötzel, K., Daniels, C., Deutschländer, A., Dillmann, U., Eisner, W., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa060281 · Cited by 2,944
Adaptive deep brain stimulation in advanced Parkinson disease.
Little, S., Pogosyan, A., Neal, S., Zavala, B., Zrinzo, L., Hariz, M., Foltynie, T., Limousin, P., Ashkan, K., FitzGerald, J., et al. (2013) · Annals of Neurology · doi:10.1002/ana.23951 · Cited by 1,374 · cited 3×
“Adaptive control algorithms utilizing STN beta band oscillations also showed rapid transitions in the classifier with frequent fluctuations in DBS amplitude [1], but these fluctuations nevertheless served to ‘shape’ the neural signal in a therapeutically useful way, by shortening the duration of ‘bursts’ of beta activ…”
BackgroundCrone, N. (1998) · Brain · doi:10.1093/brain/121.12.2301 · Cited by 1,044
Kühn, A. A., Kupsch, A., Schneider, G., & Brown, P. (2006) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2006.04717.x · Cited by 892
Kuhn, A. A., Kempf, F., Brucke, C., Gaynor Doyle, L., Martinez-Torres, I., Pogosyan, A., Trottenberg, T., Kupsch, A., Schneider, G.-H., Hariz, M. I., et al. (2008) · Journal of Neuroscience · doi:10.1523/jneurosci.0282-08.2008 · Cited by 858
Event‐related beta desynchronization in human subthalamic nucleus correlates with motor performance
Kühn, A. A., Williams, D., Kupsch, A., Limousin, P., Hariz, M., Schneider, G., Yarrow, K., & Brown, P. (2004) · Brain · doi:10.1093/brain/awh106 · Cited by 740
Spectral Changes in Cortical Surface Potentials during Motor Movement
Miller, K. J., Leuthardt, E. C., Schalk, G., Rao, R. P. N., Anderson, N. R., Moran, D. W., Miller, J. W., & Ojemann, J. G. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3886-06.2007 · Cited by 738
The modulatory effect of adaptive deep brain stimulation on beta bursts in Parkinson’s disease
Tinkhauser, G., Pogosyan, A., Little, S., Beudel, M., Herz, D. M., Tan, H., & Brown, P. (2017) · Brain · doi:10.1093/brain/awx010 · Cited by 454
Cited by
Technology of deep brain stimulation: current status and future directions
Krauss, J. K., Lipsman, N., Aziz, T., Boutet, A., Brown, P., Chang, J. W., Davidson, B., Grill, W. M., Hariz, M. I., Horn, A., et al. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-020-00426-z · Cited by 919
Gilron, R., Little, S., Perrone, R., Wilt, R., de Hemptinne, C., Yaroshinsky, M. S., Racine, C. A., Wang, S. S., Ostrem, J. L., Larson, P. S., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00897-5 · Cited by 343
Self-citationEmerging technologies for improved deep brain stimulation
Cagnan, H., Denison, T., McIntyre, C., & Brown, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0244-6 · Cited by 272
Dual threshold neural closed loop deep brain stimulation in Parkinson disease patients
Velisar, A., Syrkin-Nikolau, J., Blumenfeld, Z., Trager, M. H., Afzal, M. F., Prabhakar, V., & Bronte-Stewart, H. (2019) · Brain Stimulation · doi:10.1016/j.brs.2019.02.020 · Cited by 252
Human motor cortical beta bursts relate to movement planning and response errors
Little, S., Bonaiuto, J., Barnes, G., & Bestmann, S. (2019) · PLOS Biology · doi:10.1371/journal.pbio.3000479 · Cited by 244
Deep Brain Stimulation in Movement Disorders: From Experimental Surgery to Evidence‐Based Therapy
Krack, P., Volkmann, J., Tinkhauser, G., & Deuschl, G. (2019) · Movement Disorders · doi:10.1002/mds.27860 · Cited by 217
“cl-DBS was successfully performed by adaptively switching off the stimulator when the cortical narrow band gamma increased.(176)”
MethodTriboelectric Nanogenerators for Therapeutic Electrical Stimulation
Conta, G., Libanori, A., Tat, T., Chen, G., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202007502 · Cited by 205
Stanslaski, S., Herron, J., Chouinard, T., Bourget, D., Isaacson, B., Kremen, V., Opri, E., Drew, W., Brinkmann, B. H., Gunduz, A., et al. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2880148 · Cited by 191
“These recordings feed into a database for continuous algorithm refinement [20].”
Adaptive Deep Brain Stimulation: From Experimental Evidence Toward Practical Implementation
Neumann, W., Gilron, R., Little, S., & Tinkhauser, G. (2023) · Movement Disorders · doi:10.1002/mds.29415 · Cited by 189
“Using a single-threshold policy, stimulation is ramped to a target amplitude depending on biomarker position in relation to a threshold (eg, beta activity crossing a threshold leads to stimulation increase, or increased gamma band activity leading to stimulation decreasing).(28,36) A common dual-threshold control poli…”
BackgroundSelf-citationAn update on adaptive deep brain stimulation in Parkinson's disease
Habets, J. G. V., Heijmans, M., Kuijf, M. L., Janssen, M. L. F., Temel, Y., & Kubben, P. L. (2018) · Movement Disorders · doi:10.1002/mds.115 · Cited by 169
“4B).(5,42) Minimal and maximal stimulation amplitudes and the voltage change per step have yet to be defined.”
BackgroundVeerakumar, A., Tiruvadi, V., Howell, B., Waters, A. C., Crowell, A. L., Voytek, B., Riva-Posse, P., Denison, L., Rajendra, J. K., Edwards, J. A., et al. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00875.2018 · Cited by 89
Belkacem, A. N., Jamil, N., Khalid, S., & Alnajjar, F. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1085173 · Cited by 80
“Swann et al. (2018) showed that fully implanted neural prostheses can be used to produce adaptive deep brain stimulation for patients of Parkinson’s disease.”
BackgroundHell, F., Palleis, C., Mehrkens, J. H., Koeglsperger, T., & Bötzel, K. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00314 · Cited by 75
“This may be avoided by using ECoG sensing (101).”
BackgroundImproved detection of Parkinsonian resting tremor with feature engineering and Kalman filtering
Yao, L., Brown, P., & Shoaran, M. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.09.021 · Cited by 68
“, STN LFPs or ECoG in motor cortex (Swann et al., 2018)) may be preferred as they directly reflect brain activities that may underlie symptoms (Meidahl et al.”
Zhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67
“Multiple feasibility studies using closed-loop DBS devices like Medtronic’s Percept and Summit have demonstrated additional benefits using closed-loop versus open-loop DBS in movement disorders [103], [104].”
BackgroundRozgic, D., Hokhikyan, V., Jiang, W., Akita, I., Basir - Kazeruni, S., Chandrakumar, H., & Markovic, D. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2889040 · Cited by 49
Ramirez-Zamora, A., Giordano, J., Boyden, E. S., Gradinaru, V., Gunduz, A., Starr, P. A., Sheth, S. A., McIntyre, C. C., Fox, M. D., Vitek, J., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00936 · Cited by 37
“The effect of STN DBS was directed toward mitigating pathological neural activity related to gait, and toward restoring greater physiological information processing in the sensorimotor network, so as to improve gait and FOG in PD freezers.”
ResultInfluentialSelf-citation
Metadata
- Authors
- Swann, N. C., de Hemptinne, C., Thompson, M. C., Miocinovic, S., Miller, A. M., Gilron, R., Ostrem, J. L., Chizeck, H. J., & Starr, P. A.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2018-05-09
- Volume
- 15
- Issue
- 4
- Pages
- 046006
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2802450380
- Cited by
- 389
- References
- 29
- FWCI
- 26.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.