The DOI matches its Crossref record; 251 of the 251 references it cites were found in a registry or an index.
A comprehensive review of EEG-based brain–computer interface paradigms
Abstract
Advances in brain science and computer technology in the past decade have led to exciting developments in brain-computer interface (BCI), thereby making BCI a top research area in applied science. The renaissance of BCI opens new methods of neurorehabilitation for physically disabled people (e.g. paralyzed patients and amputees) and patients with brain injuries (e.g. stroke patients). Recent technological advances such as wireless recording, machine learning analysis, and real-time temporal resolution have increased interest in electroencephalographic (EEG) based BCI approaches. Many BCI studies have focused on decoding EEG signals associated with whole-body kinematics/kinetics, motor imagery, and various senses. Thus, there is a need to understand the various experimental paradigms used in EEG-based BCI systems. Moreover, given that there are many available options, it is essential to choose the most appropriate BCI application to properly manipulate a neuroprosthetic or neurorehabilitation device. The current review evaluates EEG-based BCI paradigms regarding their advantages and disadvantages from a variety of perspectives. For each paradigm, various EEG decoding algorithms and classification methods are evaluated. The applications of these paradigms with targeted patients are summarized. Finally, potential problems with EEG-based BCI systems are discussed, and possible solutions are proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Items 201–251 of 251
Waytowich, N. R., Faller, J., Garcia, J. O., Vettel, J. M., & Sajda, P. (2016) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2016.7844880 · Cited by 41
Iturrate, I., Montesano, L., & Mínguez, J. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610735 · Cited by 40
Time-dependent approach for single trial classification of covert visuospatial attention
Tonin, L., Leeb, R., & Millán, J. D. R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/045011 · Cited by 40
Yang, L., Leung, H. W. H., Plank, M., Snider, J., & Howard Poizner, A. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2327635 · Cited by 37
Li, T., Hong, J., Zhang, J., & Guo, F. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.11.015 · Cited by 37
Hwang, H., Han, C. H., Lim, J., Kim, Y., Choi, S., An, K.-O., Lee, J., Cha, H., Kim, S. H., & Im, C. (2016) · Psychophysiology · doi:10.1111/psyp.12793 · Cited by 36
Goal-Oriented Control with Brain-Computer Interface
Edlinger, G., Holzner, C., Groenegress, C., Guger, C., & Slater, M. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02812-0_83 · Cited by 35
Omedes, J., Iturrate, I., Montesano, L., & Mínguez, J. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610736 · Cited by 35
Hybrid EEG-NIRS based BCI for quadcopter control
Khan, M. J., Hong, K., Naseer, N., & Bhutta, M. R. (2015) · Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE) · doi:10.1109/sice.2015.7285434 · Cited by 33
Restoration of Whole Body Movement: Toward a Noninvasive Brain-Machine Interface System
Contreras-Vidal, J. L., Presacco, A., Agashe, H. A., & Paek, A. Y. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2175635 · Cited by 32
Decoding of top-down cognitive processing for SSVEP-controlled BMI
Min, B., Dähne, S., Ahn, M.-H., Noh, Y., & Müller, K. (2016) · Scientific Reports · doi:10.1038/srep36267 · Cited by 30
Hyperpnoea in man produced by sudden release of occluded blood
Mills, J. N. (1944) · The Journal of Physiology · doi:10.1113/jphysiol.1944.sp004073 · Cited by 29
Bhagat, N. A., French, J. A., Venkatakrishnan, A., Yozbatıran, N., Francisco, G. E., O’Malley, M. K., & Contreras-Vidal, J. L. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944532 · Cited by 29
Kelly, S. P., Foxe, J. J., Newman, G. I., & Edelman, J. A. (2010) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2010.07219.x · Cited by 28
A P300 based online brain-computer interface system for virtual hand control
Chen, W.-D., Zhang, J., Zhang, J., Yi, L., Qi, Y., Su, Y., Wu, B., Zhang, S., Dai, J., Zheng, X., et al. (2010) · Frontiers of Information Technology & Electronic Engineering · doi:10.1631/jzus.c0910530 · Cited by 27
The Handbook of Behavioral Medicine
Mostofsky, D. I. (2014) · Cited by 26
Nirenberg, L. M., Hanley, J., & Stear, E. B. (1971) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1971.4502880 · Cited by 25
SSVEP-BCI implementation for 37–40 Hz frequency range
Müller, S. M. T., Díez, P., Bastos-Filho, T., Sarcinelli-Filho, M., Mut, V. A., & Laciar, E. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091568 · Cited by 25
Neurofeedback and Brain–Computer Interfaces
Wyckoff, S. N., & Birbaumer, N. (2014) · Wiley eBooks · doi:10.1002/9781118453940.ch15 · Cited by 24
Marchetti, M., Piccione, F., Silvoni, S., & Priftis, K. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.07.045 · Cited by 23
Aydın, E. A., Bay, Ö. F., & Güler, İ. (2015) · Journal of Medical Systems · doi:10.1007/s10916-015-0386-0 · Cited by 23
Estimation of Forearm Supination/Pronation Motion Based on EEG Signals to Control an Artificial Arm
Kiguchi, K., Lalitharatne, T. D., & Hayashi, Y. (2013) · Journal of Advanced Mechanical Design Systems and Manufacturing · doi:10.1299/jamdsm.7.74 · Cited by 22
Improved recognition of error related potentials through the use of brain connectivity features
Zhang, H., Chavarriaga, R., Goel, M. K., Gheorghe, L., & Millán, J. D. R. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347541 · Cited by 22
Simultaneous EEG Recordings with Dry and Wet Electrodes in Motor-Imagery
Saab, J., Battes, B., & Grosse‐Wentrup, M. (2011) · Cited by 21
Noninvasive control of a robotic arm in multiple dimensions using scalp electroencephalogram
Baxter, B., Decker, A., & He, B. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6695867 · Cited by 21
Prediction of P300 BCI Aptitude in Severe Motor Impairment
Halder, S., Ruf, C. A., Furdea, A., Pasqualotto, E., Massari, D. D., van der Heiden, L., Bogdan, M., Rosenstiel, W., Birbaumer, N., Kübler, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0076148 · Cited by 21
Pokorny, C., Breitwieser, C., & Müller-Putz, G. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00152 · Cited by 21
Asynchronous Decoding of Error Potentials during the Monitoring of a Reaching Task
Omedes, J., Iturrate, I., Chavarriaga, R., & Montesano, L. (2015) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2015.541 · Cited by 20
sBCI-Headset—Wearable and Modular Device for Hybrid Brain-Computer Interface
Malechka, T., Tetzel, T., Krebs, U., Feuser, D., & Graeser, A. (2015) · Micromachines · doi:10.3390/mi6030291 · Cited by 20
Brain-Machine Interfaces: The Perception-Action Closed Loop: A Two-Learner System
Millan, J. D. R. (2015) · IEEE Systems, Man, and Cybernetics Magazine · doi:10.1109/msmc.2014.2386901 · Cited by 19 · cited 1×
“Millan [240] described the closed-loop BCI system as a ‘ two-learner system ’ .”
Brain computer interface for gesture control of a social robot: An offline study
Abiri, R., Zhao, X., Heise, G., Jiang, Y., & Abiri, F. (2017) · Iranian Conference on Electrical Engineering · doi:10.1109/iraniancee.2017.7985231 · Cited by 18
Self-citationRuf, C. A., Massari, D. D., Furdea, A., Matuz, T., Fioravanti, C., van der Heiden, L., Halder, S., & Birbaumer, N. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00023 · Cited by 17
Somatosensory evoked potentials elicited by stimulating two fingers from one hand — Usable for BCI?
Breitwieser, C., Pokorny, C., Neuper, C., & Müller-Putz, G. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091573 · Cited by 15
A Review on Visual Brain Computer Interface
Kapgate, D. D., & Kalbande, D. R. (2015) · Lecture notes in bioengineering · doi:10.1007/978-81-322-2256-9_18 · Cited by 14
Machado, S. E. D. C., Almada, L. F., & Annavarapu, R. N. (2013) · Cited by 14
Cortical current density vs. surface EEG for event-related potential-based Brain-Computer Interface
Goel, M. K., Chavarriaga, R., & Millán, J. D. R. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910578 · Cited by 14
Implementation of EEG based control of remote robotic systems
Chakraborti, T., Sengupta, A., Banerjee, D., Konar, A., Bhattacharyya, S., Khasnobish, A., & Janarthanan, R. (2011) · IEEE International Conference on Recent Trends in Information Systems · doi:10.1109/retis.2011.6146868 · Cited by 14
Early detection of hand movements from electroencephalograms for stroke therapy applications
Muralidharan, A., Chae, J., & Taylor, D. M. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046003 · Cited by 13
Airborne Ultrasonic Tactile Display Brain-computer Interface ParadigmPreprint
Hamada, K., Mori, H., Shinoda, H., et al. (2014) · arXiv (Cornell University) · doi:10.3217/978-3-85125-378-8-18 · Cited by 11
EEG ‐Based Brain‐Computer Interface System
Pfurtscheller, G., Graimann, B., & Neuper, C. (2006) · Wiley eBooks · doi:10.1002/9780471740360.ebs1309 · Cited by 10
Recent Progress in Brain and Cognitive Engineering
Lee, S., Bülthoff, H., & Müller, K. (2015) · Trends in augmentation of human performance · doi:10.1007/978-94-017-7239-6 · Cited by 10
Real-Time Brain Machine Interaction via Social Robot Gesture Control
Abiri, R., Borhani, S., Zhao, X., & Jiang, Y. (2017) · ASME Dynamic Systems and Control Conference (DSCC) · doi:10.1115/dscc2017-5128 · Cited by 10
Self-citationModeling the Functional Dependence of Stroke Patients: The Outcome of an Improved Gait Training
Hennings, K., Gervasio, S., Andersen, O. K., & Spaich, E. G. (2014) · Biosystems & biorobotics · doi:10.1007/978-3-319-08072-7_64 · Cited by 9
EEG driven model predictive position control of an artificial limb using neural net
Roy, R., Konar, A., Tibarewala, D. N., & Janarthanan, R. (2012) · International Conference on Computing, Communication and Networking Technologies (ICCCNT) · doi:10.1109/icccnt.2012.6395913 · Cited by 8
Observation-based training for neuroprosthetic control of grasping by amputees
Agashe, H. A., & Contreras-Vidal, J. L. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944498 · Cited by 8
CLASSIFICATION OF EYELID POSITION AND EYEBALL MOVEMENT USING EEG SIGNALS
Ramli, R., Arof, H., Ibrahim, F., Idris, M. Y. I., & Khairuddin, A. S. M. (2015) · Malaysian Journal of Computer Science · Cited by 7
Development of a Wearable Electroencephalographic Device for Anxiety Monitoring1
Suresh, S., Liu, Y., & Yeow, C. (2015) · Journal of Medical Devices · doi:10.1115/1.4030553 · Cited by 7
EEG-Based Classification of Imagined Arm Trajectories
Ofner, P., & Müller-Putz, G. (2014) · Biosystems & biorobotics · doi:10.1007/978-3-319-08072-7_88 · Cited by 5
Observation-based calibration of brain-machine interfaces for grasping
Agashe, H. A., & Contreras-Vidal, J. L. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6695856 · Cited by 4
A Brain-Machine Interface for a Sequence Movement Control of a Robotic Arm
Abiri, R., Kilmarx, J., Borhani, S., Zhao, X., & Jiang, Y. (2017) · HAL · Cited by 3
Self-citationMoving Brain-Controlled Devices Outside the Lab: Principles and Applications
Leeb, R., Chavarriaga, R., Perdikis, S., Iturrate, I., & Millán, J. D. R. (2015) · Trends in augmentation of human performance · doi:10.1007/978-94-017-7239-6_6 · Cited by 2
Cited by
A Survey on the Metaverse: The State-of-the-Art, Technologies, Applications, and Challenges
Wang, H., Ning, H., Lin, Y., Wang, W., Dhelim, S., Farha, F., Ding, J., & Daneshmand, M. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3278329 · Cited by 716
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Past, Present, and Future of EEG-Based BCI Applications
Värbu, K., Muhammad, N., & Muhammad, Y. (2022) · Sensors · doi:10.3390/s22093331 · Cited by 321
Interface, interaction, and intelligence in generalized brain–computer interfaces
Gao, X., Wang, Y., Chen, X., & Gao, S. (2021) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2021.04.003 · Cited by 304
Brain-Controlled Robotic Arm System Based on Multi-Directional CNN-BiLSTM Network Using EEG Signals
Jeong, J.-H., Shim, K.-H., Kim, D.-J., & Lee, S.-W. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2981659 · Cited by 292
Metadata
- Authors
- Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2019-01-09
- Volume
- 16
- Issue
- 1
- Pages
- 011001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2900802277
- Cited by
- 946
- References
- 251
- FWCI
- 30.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.