Comparing user-dependent and user-independent training of CNN for SSVEP BCI
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We presented a comparative study on the training methodologies of a convolutional neural network (CNN) for the detection of steady-state visually evoked potentials (SSVEP). Two training scenarios were also compared: user-independent (UI) training and user-dependent (UD) training. APPROACH: The CNN was trained in both UD and UI scenarios on two types of features for SSVEP classification: magnitude spectrum features (M-CNN) and complex spectrum features (C-CNN). The canonical correlation analysis (CCA), widely used in SSVEP processing, was used as the baseline. Additional comparisons were performed with task-related components analysis (TRCA) and filter-bank canonical correlation analysis (FBCCA). The performance of the proposed CNN pipelines, CCA, FBCCA and TRCA were evaluated with two datasets: a seven-class SSVEP dataset collected on 21 healthy participants and a twelve-class publicly available SSVEP dataset collected on ten healthy participants. MAIN RESULTS: The UD based training methods consistently outperformed the UI methods when all other conditions were the same, as one would expect. However, the proposed UI-C-CNN approach performed similarly to the UD-M-CNN across all cases investigated on both datasets. On Dataset 1, the average accuracies of the different methods for 1 s window length were: CCA: 69.1% ± 10.8%, TRCA: 13.4% ± 1.5%, FBCCA: 64.8% ± 15.6%, UI-M-CNN: 73.5% ± 16.1%, UI-C-CNN: 81.6% ± 12.3%, UD-M-CNN: 87.8% ± 7.6% and UD-C-CNN: 92.5% ± 5%. On Dataset 2, the average accuracies of the different methods for data length of 1 s were: UD-C-CNN: 92.33% ± 11.1%, UD-M-CNN: 82.77% ± 16.7%, UI-C-CNN: 81.6% ± 18%, UI-M-CNN: 70.5% ± 22%, FBCCA: 67.1% ± 21%, CCA: 62.7% ± 21.5%, TRCA: 40.4% ± 14%. Using t-SNE, visualizing the features extracted by the CNN pipelines further revealed that the C-CNN method likely learned both the amplitude and phase related information from the SSVEP data for classification, resulting in superior performance than the M-CNN methods. The results suggested that UI-C-CNN method proposed in this study offers a good balance between performance and cost of training data. SIGNIFICANCE: The proposed C-CNN based method is a suitable candidate for SSVEP-based BCIs and provides an improved performance in both UD and UI training scenarios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2008) · Journal of Machine Learning Research · Cited by 33,051
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S., & Szegedy, C. (2015) · arXiv · doi:10.48550/arxiv.1502.03167 · Cited by 27,818
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S. (2024) · arXiv (Cornell University) · doi:10.57702/o9raffed · Cited by 14,214
EEGNet: a compact convolutional neural network for EEG-based brain-computer interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aace8c · Cited by 5,115 · cited 4×
“%) achieves the highest performance compared to CCA (62.7% ± 21.5%), UI-M-CNN (70.5% ± 22%), FBCCA (67.1% ± 21%), Compact-CNN (79% ± 15”
MethodInfluentialEEGNet: A Compact Convolutional Network for EEG-based Brain-Computer Interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2016) · arXiv · doi:10.48550/arxiv.1611.08024 · Cited by 5,105 · cited 4×
“%) achieves the highest performance compared to CCA (62.7% ± 21.5%), UI-M-CNN (70.5% ± 22%), FBCCA (67.1% ± 21%), Compact-CNN (79% ± 15”
MethodInfluentialA review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239 · cited 1×
“In a recent study, it was reported that a vast majority of published studies based on deep learning for EEG based BCIs did not compare the proposed techniques to state-of-the-art methods or they performed biased comparisons [40].”
BackgroundDeep learning for electroencephalogram (EEG) classification tasks: a review
Craik, A., He, Y., & Contreras-Vidal, J. L. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0ab5 · Cited by 1,758
Deep learning-based electroencephalography analysis: a systematic review
Roy, Y., Banville, H., Albuquerque, I., Gramfort, A., Falk, T. H., & Faubert, J. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab260c · Cited by 1,532 · cited 1×
“One of the key challenges highlighted in deep learning based methods for BCIs is the reproducibility of results [18], where the authors provided guidelines such as: providing a clear description of the architecture, clearly describing the data used, use of existing datasets and evaluating the performance with baseline.”
BackgroundDeep learning for healthcare applications based on physiological signals: A review
Faust, O., Hagiwara, Y., Hong, T. J., Lih, O. S., & Acharya, U. R. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.005 · Cited by 1,026
High-speed spelling with a noninvasive brain–computer interface
Chen, X., Wang, Y., Nakanishi, M., Gao, X., Jung, T.-P., & Gao, S. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1508080112 · Cited by 969
Cited by
Summary of over Fifty Years with Brain-Computer Interfaces—A Review
Kawala-Sterniuk, A., Browarska, N., Al-Bakri, A., Pelc, M., Zygarlicki, J., Sidikova, M., Martinek, R., & Gorzelanczyk, E. J. (2021) · Brain Sciences · doi:10.3390/brainsci11010043 · Cited by 292
“The SSVEP-BCIs also require little or not training, what makes it a great candidate for real-life applications [113,118].”
BackgroundA transformer-based deep neural network model for SSVEP classification
Chen, J., Zhang, Y., Pan, Y., Xu, P., & Guan, C. (2023) · Neural Networks · doi:10.1016/j.neunet.2023.04.045 · Cited by 170
A Deep Neural Network for SSVEP-Based Brain-Computer Interfaces
Güney, O. B., Oblokulov, M., & Özkan, H. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3110440 · Cited by 153
“Indeed, subject specific adaptation has been observed in [39] to largely improve the identification performance.”
BackgroundKohli, V., Tripathi, U., Chamola, V., Rout, B. K., & Kanhere, S. S. (2021) · Microprocessors and Microsystems · doi:10.1016/j.micpro.2021.104392 · Cited by 137
Review of brain encoding and decoding mechanisms for EEG-based brain–computer interface
Xu, L., Xu, M., Jung, T., & Ming, D. (2021) · Cognitive Neurodynamics · doi:10.1007/s11571-021-09676-z · Cited by 110
Metadata
- Authors
- Ravi, A., Beni, N. H., Manuel, J., & Jiang, N.
- Affiliations
- University of Waterloo (CA)
- Corresponding author
- Jiang, Ning
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2020-04-01
- Volume
- 17
- Issue
- 2
- Pages
- 026028
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W3000563309
- Cited by
- 165
- References
- 46
- Citations by year
- 2026: 14 · 2025: 43 · 2024: 40 · 2023: 22 · 2022: 24 · 2021: 17 · 2020: 5
- FWCI
- 9.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/3.0/ (vor, 7 d)
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 7 d)
- Locations
- Journal of Neural Engineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada (401261605)
- NSERC – CREATE, Training in Global Biomedical Technology Research and Innovation at the University of Waterloo. (401207296)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Keywords
- steady-state visual evoked potentials, SSVEP-based brain-computer interface, convolutional neural networks, canonical correlation analysis, filter bank canonical correlation analysis, SSVEP classification, EEG feature extraction
- MeSH terms
- Algorithms, Electroencephalography, Evoked Potentials, Evoked Potentials, Visual, Humans, Photic Stimulation, Neural Networks, Computer, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparing user-dependent and user-independent training of CNN for SSVEP BCI. https://app.cochat.ai/papers/10.1088/1741-2552/ab6a67
- The paper
- Ravi, A., Beni, N. H., Manuel, J., & Jiang, N. (2020). Comparing user-dependent and user-independent training of CNN for SSVEP BCI. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/ab6a67
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.