Long-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients
Open accessAbstract
Objective. The evaluation of the long-term stability of ElectroCorticoGram (ECoG) signals is an important scientific question as new implantable recording devices can be used for medical purposes such as Brain-Computer Interface (BCI) or brain monitoring. Approach. The long-term clinical validation of wireless implantable multi-channel acquisition system for generic interface with neurons (WIMAGINE), a wireless 64-channel epidural ECoG recorder was investigated. The WIMAGINE device was implanted in two quadriplegic patients within the context of a BCI protocol. This study focused on the ECoG signal stability in two patients bilaterally implanted in June 2017 (P1) and in November 2019 (P2). Methods . The ECoG signal was recorded at rest prior to each BCI session resulting in a 32 month and in a 14 month follow-up for P1 and P2 respectively. State-of-the-art signal evaluation metrics such as root mean square (RMS), the band power (BP), the signal to noise ratio (SNR), the effective bandwidth (EBW) and the spectral edge frequency (SEF) were used to evaluate stability of signal over the implantation time course. The time-frequency maps obtained from task-related motor activations were also studied to investigate the long-term selectivity of the electrodes. Main results. Based on temporal linear regressions, we report a limited decrease of the signal average level (RMS), spectral distribution (BP) and SNR, and a remarkable steadiness of the EBW and SEF. Time-frequency maps obtained during motor imagery, showed a high level of discrimination 1 month after surgery and also after 2 years. Conclusions. The WIMAGINE epidural device showed high stability over time. The signal evaluation metrics of two quadriplegic patients during 32 months and 14 months respectively provide strong evidence that this wireless implant is well-suited for long-term ECoG recording. Significance. These findings are relevant for the future of implantable BCIs, and could benefit other patients with spinal cord injury, amyotrophic lateral sclerosis, neuromuscular diseases or drug-resistant epilepsy.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A comparable robustness and stability of this computational and technological brain decoding framework has now been observed in two additional individuals with tetraplegia.
“Third, a comparable robustness and stability of this computational and technological brain decoding framework has now been observed in two additional individuals with tetraplegia3,26,29.”
From Walking naturally after spinal cord injury using a brain–spine interface (2023) · cites this paper as [29]
The Discussion and Conclusion report stable WIMAGINE recordings in two tetraplegic patients enrolled in a BCI protocol. They do not establish comparable robustness of the full computational brain-decoding framework in two additional individuals: the paper evaluates recorder signals, and the Discussion says training for patient 2 was ongoing. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · see citing works
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · see citing works
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · see citing works
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188 · see citing works
Targeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087 · see citing works
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924 · see citing works
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · see citing works
Cook, M. J., O'Brien, T. J., Berkovic, S. F., Murphy, M. A., Morokoff, A. P., Fabinyi, G., D'Souza, W. J., Yerra, R., Archer, J. S., Litewka, L., et al. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70075-9 · Cited by 881 · see citing works
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862 · see citing works
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792 · see citing works
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704 · see citing works
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600 · see citing works
Pandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566 · see citing works
Two-dimensional movement control using electrocorticographic signals in humans
Schalk, G., Miller, K. J., Anderson, N., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/008 · Cited by 481 · see citing works
Benabid, A. L., Costecalde, T., Eliseyev, A., Charvet, G., Verney, A., Karakas, S., Foerster, M., Lambert, A., Morinière, B., Abroug, N., et al. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30321-7 · Cited by 404 · see citing works
Self-citationAn Electrocorticographic Brain Interface in an Individual with Tetraplegia
Wang, W., Collinger, J. L., Degenhart, A. D., Tyler‐Kabara, E. C., Schwartz, A. B., Moran, D. W., Weber, D. J., Wodlinger, B., Vinjamuri, R. K., Ashmore, R. C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055344 · Cited by 396 · see citing works
Oxley, T. J., Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Wheeler, T. L., Judy, J. W., McDonald, A. J., Dornom, A., Lovell, T. J. H., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3428 · Cited by 346 · see citing works
Visualization of significant ERD/ERS patterns in multichannel EEG and ECoG data
Graimann, B., Huggins, J. E., Levine, S. P., & Pfurtscheller, G. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00697-6 · Cited by 302 · see citing works
Automatic seizure detection: improvements and evaluation
Gotman, J. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90032-f · Cited by 291 · see citing works
Human Motor Cortical Activity Is Selectively Phase-Entrained on Underlying Rhythms
Miller, K. J., Hermes, D., Honey, C. J., Hebb, A. O., Ramsey, N. F., Knight, R. T., Ojemann, J. G., & Fetz, E. E. (2012) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1002655 · Cited by 235 · see citing works
Transferring Subspaces Between Subjects in Brain--Computer Interfacing
Samek, W., Meinecke, F. C., & Müller, K. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2253608 · Cited by 216 · see citing works
Simultaneous EEG 10 Hz desynchronization and 40 Hz synchronization during finger movements
Pfurtscheller, G., & Neuper, C. (1992) · Neuroreport · doi:10.1097/00001756-199212000-00006 · Cited by 210 · see citing works
WIMAGINE: Wireless 64-Channel ECoG Recording Implant for Long Term Clinical Applications
Mestais, C. S., Charvet, G., Sauter-Starace, F., Foerster, M., Ratel, D., & Benabid, A. L. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2333541 · Cited by 202 · see citing works
Self-citationIntegrated analysis of anatomical and electrophysiological human intracranial data
Stolk, A., Griffin, S., van der Meij, R., Dewar, C. D., Sáez, I., Lin, J. J., Piantoni, G., Schoffelen, J., Knight, R. T., & Oostenveld, R. (2018) · Nature Protocols · doi:10.1038/s41596-018-0009-6 · Cited by 167 · see citing works
A Model for Studying Depth of Anesthesia and Acute Tolerance to Thiopental
Hudson, R. J., Stanski, D. R., Saidman, L. J., & Meathe, E. (1983) · Anesthesiology · doi:10.1097/00000542-198310000-00006 · Cited by 162 · see citing works
Optimal spacing of surface electrode arrays for brain–machine interface applications
Slutzky, M. W., Jordan, L. R., Krieg, T. D., Chen, M., Mogul, D. J., & Miller, L. E. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026004 · Cited by 161 · see citing works
Swann, N. C., de Hemptinne, C., Miocinovic, S., Qasim, S. E., Ostrem, J. L., Galifianakis, N. B., Luciano, M. S., Wang, S. S., Ziman, N., Taylor, R., et al. (2017) · Journal of neurosurgery · doi:10.3171/2016.11.jns161162 · Cited by 144 · see citing works
Sillay, K. A., Rutecki, P. A., Cicora, K., Worrell, G. A., Drazkowski, J. F., Shih, J. J., Sharan, A. D., Morrell, M. J., Williams, J. C., & Wingeier, B. (2013) · Brain stimulation · doi:10.1016/j.brs.2013.02.001 · Cited by 134 · see citing works
Plug-and-play control of a brain–computer interface through neural map stabilization
Silversmith, D. B., Abiri, R., Hardy, N. F., Natraj, N., Tu-Chan, A., Chang, E. F., & Ganguly, K. (2021) · Nature Biotechnology · doi:10.1038/s41587-020-0662-5 · Cited by 126 · see citing works
Complications and results of subdural grid electrode implantation in epilepsy surgery
Lee, W.-S., Lee, J. K., Lee, S., et al. (2000) · Surgical Neurology · doi:10.1016/s0090-3019(00)00324-4 · Cited by 124 · see citing works
Classic electroencephalographic parameters: Median frequency, spectral edge frequency etc
Tonner, P. H., & Bein, B. (2006) · Best practice & research. Clinical anaesthesiology · doi:10.1016/j.bpa.2005.08.008 · Cited by 114 · see citing works
Epileptic seizures associated with intrathecal baclofen application
Köfler, M., Kronenberg, M. F., Rifici, C., Saltuari, L. L., & Bauer, G. (1994) · Neurology · doi:10.1212/wnl.44.1.25 · Cited by 105 · see citing works
Pels, E., Aarnoutse, E. J., Leinders, S., Freudenburg, Z. V., Branco, M. P., van der Vijgh, B. H., Snijders, T. J., Denison, T., Vansteensel, M. J., & Ramsey, N. F. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.07.020 · Cited by 95 · see citing works
Degenhart, A. D., Eles, J. R., Dum, R. P., Mischel, J., Smalianchuk, I., Endler, B., Ashmore, R. C., Tyler‐Kabara, E. C., Hatsopoulos, N. G., Wang, W., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046019 · Cited by 92 · see citing works
Wiggins, G. C., Elisevich, K. V., & Smith, B. J. (1999) · Epilepsy Research · doi:10.1016/s0920-1211(99)00037-6 · Cited by 88 · see citing works
Levels of brain wave activity (8–13 Hz) in persons with spinal cord injury
Tran, Y., Boord, P., Middleton, J. W., et al. (2004) · Spinal Cord · doi:10.1038/sj.sc.3101543 · Cited by 79 · see citing works
The effect of micro-ECoG substrate footprint on the meningeal tissue response
Schendel, A. A., Nonte, M. W., Vokoun, C. R., Richner, T. J., Brodnick, S. K., Atry, F., Frye, S. T., Bostrom, P., Pashaie, R., Thongpang, S., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046011 · Cited by 67 · see citing works
Intracranial EEG fluctuates over months after implanting electrodes in human brain
Ung, H., Baldassano, S. N., Bink, H., Krieger, A. Μ., Roberson, S. W., Vitale, F., Wu, C., Freestone, D. R., Nurse, E. S., Leyde, K. W., et al. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7f40 · Cited by 67 · see citing works
Consistency of Long-Term Subdural Electrocorticography in Humans
Nurse, E. S., John, S. E., Freestone, D. R., Oxley, T. J., Ung, H., Berkovic, S. F., O'Brien, T. J., Cook, M. J., & Grayden, D. B. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2768442 · Cited by 59 · see citing works
Bundy, D. T., Zellmer, E. R., Gaona, C. M., Sharma, M., Szrama, N. P., Hacker, C. D., Freudenburg, Z. V., Daitch, A. L., Moran, D. W., & Leuthardt, E. C. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016006 · Cited by 57 · see citing works
Comparison of decoding resolution of standard and high-density electrocorticogram electrodes
Wang, P. T., King, C., McCrimmon, C. M., Lin, J. J., Sazgar, M., Hsu, F. P. K., Shaw, S. J., Millet, D. E., Chui, L. A., Liu, C. Y., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026016 · Cited by 56 · see citing works
Ryapolova-Webb, E. S., Afshar, P., Stanslaski, S. R., Denison, T., de Hemptinne, C., Bankiewicz, K. S., & Starr, P. A. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016009 · Cited by 54 · see citing works
Sound motion evoked magnetic fields
Xiang, J., Chuang, S. H., Wilson, D., et al. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00709-x · Cited by 50 · see citing works
Spatial co-adaptation of cortical control columns in a micro-ECoG brain–computer interface
Rouse, A. G., Williams, J. J., Wheeler, J. J., & Moran, D. W. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056018 · Cited by 40 · see citing works
Gain of the human dura in vivo and its effects on invasive brain signal feature detection
Valderrama, A. T., Oostenveld, R., Vansteensel, M. J., et al. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.01.019 · Cited by 34 · see citing works
Wu, C., Evans, J. J., Skidmore, C. T., et al. (2012) · Neuromodulation Technology at the Neural Interface · doi:10.1111/j.1525-1403.2012.00529.x · Cited by 30 · see citing works
A Low-Power 0.7 $\mu {\rm V_{rms}}$ 32-Channel Mixed-Signal Circuit for ECoG Recordings
Robinet, S., Audebert, P., Regis, G., Zongo, B., Beche, J.-F., Condemine, C., Filipe, S., & Charvet, G. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2180835 · Cited by 30 · see citing works
Self-citationLong-Term Sheep Implantation of WIMAGINE®, a Wireless 64-Channel Electrocorticogram Recorder
Sauter-Starace, F., Ratel, D., Crétallaz, C., Foerster, M., Lambert, A., Gaude, C., Costecalde, T., Bonnet, S., Charvet, G., Aksenova, T., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00847 · Cited by 30 · see citing works
Self-citationApport de l'EEG dans le diagnostic d'une intoxication au baclofène
Boutte, C., Vercueil, L., Durand, M., Vincent, F., & Alvarez, J. (2006) · Neurophysiologie Clinique · doi:10.1016/j.neucli.2006.03.004 · Cited by 24 · see citing works
The auditory p300-based SSBCI: A door to minimally conscious patients?
Muller-Putz, G. R., Klobassa, D. S., Pokorny, C., Pichler, G., Erlbeck, H., Real, R. G. L., Kübler, A., Risetti, M., & Donatella Mattia, A. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347009 · Cited by 19 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Walking naturally after spinal cord injury using a brain–spine interface
Lorach, H., Galvez, A., Spagnolo, V., Martel, F., Karakas, S., Intering, N., Vat, M., Faivre, O., Harte, C., Komi, S., et al. (2023) · Nature · doi:10.1038/s41586-023-06094-5 · Cited by 631 · see citing works
“Third, a comparable robustness and stability of this computational and technological brain decoding framework has now been observed in two additional individuals with tetraplegia 3,26,29 .”
BackgroundSelf-citationMoly, A., Costecalde, T., Martel, F., Martin, M., Larzabal, C., Karakas, S., Verney, A., Charvet, G., Chabardes, S., Benabid, A. L., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac59a0 · Cited by 65 · see citing works
Self-citation
- Authors
- Larzabal, C., Bonnet, S., Costecalde, T., Auboiroux, V., Charvet, G., Chabardes, S., Aksenova, T., & Sauter-Starace, F.
- Affiliations
- Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR)
- Corresponding author
- Sauter-Starace, Fabien
- ORCID
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2021-09-09
- Volume
- 18
- Issue
- 5
- Pages
- 056026
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W3194083387
- Cited by
- 37
- References
- 51
- Citations by year
- 2026: 6 · 2025: 9 · 2024: 6 · 2023: 9 · 2022: 6 · 2021: 1
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Funders
- Fondation Philanthropique Edmond J Safra
- Fondation Motrice
- Fondation Nanosciences
- Fonds de Dotation Clinatec
- French Ministry of Health (PHRC-15-15-0124)
- Institut Carnot
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- tetraplegia, brain-computer interface, quadriplegic patients, signal-to-noise ratio, effective bandwidth, spectral edge frequency, band power, motor imagery, electrode selectivity, spinal cord injury
- MeSH terms
- Electrocorticography, Brain, Electrodes, Implanted, Electroencephalography, Epidural Space, Humans, Wireless Technology, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review