Pathological tremor prediction using surface electromyogram and acceleration: potential use in ‘ON–OFF’ demand driven deep brain stimulator design
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We present a proof of concept for a novel method of predicting the onset of pathological tremor using non-invasively measured surface electromyogram (sEMG) and acceleration from tremor-affected extremities of patients with Parkinson's disease (PD) and essential tremor (ET). APPROACH: The tremor prediction algorithm uses a set of spectral (Fourier and wavelet) and nonlinear time series (entropy and recurrence rate) parameters extracted from the non-invasively recorded sEMG and acceleration signals. MAIN RESULTS: The resulting algorithm is shown to successfully predict tremor onset for all 91 trials recorded in 4 PD patients and for all 91 trials recorded in 4 ET patients. The predictor achieves a 100% sensitivity for all trials considered, along with an overall accuracy of 85.7% for all ET trials and 80.2% for all PD trials. By using a Pearson's chi-square test, the prediction results are shown to significantly differ from a random prediction outcome. SIGNIFICANCE: The tremor prediction algorithm can be potentially used for designing the next generation of non-invasive closed-loop predictive ON-OFF controllers for deep brain stimulation (DBS), used for suppressing pathological tremor in such patients. Such a system is based on alternating ON and OFF DBS periods, an incoming tremor being predicted during the time intervals when DBS is OFF, so as to turn DBS back ON. The prediction should be a few seconds before tremor re-appears so that the patient is tremor-free for the entire DBS ON-OFF cycle and the tremor-free DBS OFF interval should be maximized in order to minimize the current injected in the brain and battery usage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811
Assessing the accuracy of prediction algorithms for classification: an overview
Baldi, P., Brunak, S., Chauvin, Y., Andersen, C. A. F., & Nielsen, H. (2000) · Bioinformatics · doi:10.1093/bioinformatics/16.5.412 · Cited by 2,111
Closed-Loop Deep Brain Stimulation Is Superior in Ameliorating Parkinsonism
Rosin, B., Slovik, M., Mitelman, R., Rivlin-Etzion, M., Haber, S. N., Israel, Z., Vaadia, E., & Bergman, H. (2011) · Neuron · doi:10.1016/j.neuron.2011.08.023 · Cited by 793
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Self-citationLong-term follow-up of thalamic deep brain stimulation for essential and parkinsonian tremor
Kumar, R., Lozano, A. M., Sime, E., & Lang, A. E. (2003) · Neurology · doi:10.1212/01.wnl.0000096012.07360.1c · Cited by 210
Time-frequency analysis of tremors
O'Suilleabhain, P. (1998) · Brain · doi:10.1093/brain/121.11.2127 · Cited by 157
Pilitsis, J. G., Metman, L. V., Toleikis, J. R., Hughes, L. E., Sani, S. B., & Bakay, R. A. E. (2008) · Journal of Neurosurgery · doi:10.3171/jns/2008/109/10/0640 · Cited by 129
Self-citationThalamotomy for essential and cerebellar tremor
Shahzadi, S., Tasker, R. R., & Lozano, A. (1996) · Stereotactic and Functional Neurosurgery · doi:10.1159/000098890 · Cited by 84
WIDJAJA, F., SHEE, C. Y., ANG, W. T., AU, W. L., & POIGNET, P. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519411004344 · Cited by 14
Cited by
Technology of deep brain stimulation: current status and future directions
Krauss, J. K., Lipsman, N., Aziz, T., Boutet, A., Brown, P., Chang, J. W., Davidson, B., Grill, W. M., Hariz, M. I., Horn, A., et al. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-020-00426-z · Cited by 919
Technology in Parkinson’s disease: challenges and opportunities
Espay, A. J., Bonato, P., Nahab, F. B., Maetzler, W., Dean, J. M., Klucken, J., Eskofier, B. M., Merola, A., Horak, F., Lang, A. E., et al. (2016) · Movement Disorders · doi:10.1002/mds.26642 · Cited by 654
“Proof of concept systems have been developed to predict the onset of pathological tremor using surface electromyographic and acceleration data, which could inform the design of the next generation of noninvasive closedloop predictive ON-OFF controllers for DBS.62,63 In the realm of physical rehabilitation, subtle asym…”
BackgroundClosed-loop Neurostimulation: The Clinical Experience
Sun, F. T., & Morrell, M. J. (2014) · Neurotherapeutics · doi:10.1007/s13311-014-0280-3 · Cited by 286
Emerging technologies for improved deep brain stimulation
Cagnan, H., Denison, T., McIntyre, C., & Brown, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0244-6 · Cited by 272
Stimulating at the right time: phase-specific deep brain stimulation
Cagnan, H., Pedrosa, D., Little, S., Pogosyan, A., Cheeran, B., Aziz, T., Green, A., Fitzgerald, J., Foltynie, T., Limousin, P., et al. (2017) · Brain · doi:10.1093/brain/aww286 · Cited by 270
Advances in closed-loop deep brain stimulation devices
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0295-1 · Cited by 232
“Some of these devices close the feedback loop by turning the stimulation on and off known as ondemand stimulation [31, 32, 104, 141].”
BackgroundAdaptive Deep Brain Stimulation for Movement Disorders: The Long Road to Clinical Therapy
Meidahl, A. C., Tinkhauser, G., Herz, D. M., Cagnan, H., Debarros, J., & Brown, P. (2017) · Movement Disorders · doi:10.1002/mds.27022 · Cited by 193
“Control algorithms usually involve simple thresholding of processed signals, but can be more sophisticated, and utilize additional information about whether the patient is engaged in rest, posture, or action.(45) The nature of the telemetric link and implanted IPG has meant that stimulation is then controlled with an…”
BackgroundAn Upper-Limb Power-Assist Exoskeleton Using Proportional Myoelectric Control
Tang, Z., Zhang, K., Sun, S., Gao, Z., Zhang, L., & Yang, Z. (2014) · Sensors · doi:10.3390/s140406677 · Cited by 182
“However, most EMG control methods belong to on-off control (constant speed in one direction or full stop) [10–13].”
BackgroundAn update on adaptive deep brain stimulation in Parkinson's disease
Habets, J. G. V., Heijmans, M., Kuijf, M. L., Janssen, M. L. F., Temel, Y., & Kubben, P. L. (2018) · Movement Disorders · doi:10.1002/mds.115 · Cited by 169
“eral seconds before tremor reoccurs based on tremor prediction using machine-learning algorithms.(46,48)”
MethodOnline tremor suppression using electromyography and low-level electrical stimulation
Dosen, S., Muceli, S., Dideriksen, J. L., Romero, J. P., Rocon, E., Pons, J., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328296 · Cited by 120
“Previous studies suggested that surface electromyography signals (EMG) could be used as input for tremor detection/prediction and parameter estimation [21]–[24].”
BackgroundA Soft Exoskeleton for Tremor Suppression Equipped with Flexible Semiactive Actuator
Zahedi, A., Zhang, B., Yi, A., & Zhang, D. (2021) · Soft Robotics · doi:10.1089/soro.2019.0194 · Cited by 57
Shah, A., Coste, J., Lemaire, J.-J., Taub, E., Schüpbach, W. M. M., Pollo, C., Schkommodau, E., Guzman, R., & Hemm-Ode, S. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1559-9 · Cited by 21
“Closed-loop systems have been proposed that are based not only on electrophysiological signals [10], but also on EMG and acceleration signals of tremor [3].”
Background
Metadata
- Authors
- Basu, I., Graupe, D., Tuninetti, D., Shukla, P., Slavin, K. V., Metman, L. V., & Corcos, D. M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-05-08
- Volume
- 10
- Issue
- 3
- Pages
- 036019
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2021930808
- Cited by
- 99
- References
- 10
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.