Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Factors involved in long-term efficacy of deep brain stimulation of the thalamus for essential tremor: Clinical article

Pilitsis, Julie G., Metman, Leo Verhagen, Toleikis, John R., Hughes, Lindsay E., Sani, Sepehr B., Bakay, Roy A. E. · 2008 · Journal of Neurosurgery

Abstract

Object: Although nucleus ventralis intermedius stimulation has been shown to be safe and efficacious in the treatment of essential tremor, there is a subset of patients who eventually lose benefit from their stimulation. Proposed causes for this phenomenon include tolerance, disease progression, and suboptimal location. The goal of this study was to assess the factors that may lead to both stimulation failure, defined as loss of meaningful tremor relief, and less satisfactory outcomes, defined as leads requiring voltages > 3.6 V for effective tremor control. Methods: The authors present their clinical outcomes from 31 leads in 27 patients who had effective tremor control for > 1 year following nucleus ventralis intermedius stimulation. All patients postoperatively had a mean decrease in both the writing and drawing subscales of the Fahn-Tolosa-Marin Tremor Rating Scale (p < 0.001). Results: After a mean follow-up of 40 months, 22 patients continued to have tremor control with stimulation. Four patients eventually lost efficacy of their stimulation at a mean of 39 months. There was no difference in age, duration of disease, or disease severity between the groups. Examination of perioperative factors revealed that suboptimal anteroposterior positioning as evidenced on intraoperative fluoroscopy occurred significantly more frequently in patients with stimulation failure (p = 0.018). In patients with less satisfactory outcomes, no difference was seen between group demographics. Fluoroscopy again revealed suboptimal positioning more frequently in these patients (p = 0.005). Conclusions: This study provides further evidence that suboptimal lead position in combination with disease progression or tolerance may result in less satisfactory long-term outcomes.

Overview

Integrity signals

Registry

Crossref · 10.3171/jns/2008/109/10/0640

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 36 references

Cited by

See all 129

Metadata

Authors
Pilitsis, J. G., Metman, L. V., Toleikis, J. R., Hughes, L. E., Sani, S. B., & Bakay, R. A. E.
Affiliations
  • UMass Memorial Medical Center (US)
  • Neurology, and
  • Rush University Medical Center (US)
  • Departments of Neurosurgery,
Corresponding author
Bakay, Roy A. E.
Venue
Journal of Neurosurgery
Published
2008-10
Volume
109
Issue
4
Pages
640-646
ISSN
  • 0022-3085 (ISSN-L)
  • 1933-0693
OpenAlex
W1551458386
Cited by
129
References
36
Citations by year
2026: 3 · 2025: 8 · 2024: 7 · 2023: 2 · 2022: 7 · 2021: 6 · 2020: 14 · 2019: 8 · 2018: 14 · 2017: 12 · 2016: 7 · 2015: 2 · 2014: 8 · 2013: 10 · 2012: 9
FWCI
2.55
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of neurosurgery (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Medtronic
  • Rush University
Topics
  • Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
  • Social Sciences › Psychology › Clinical Psychology › Obsessive-Compulsive Spectrum Disorders
  • Health Sciences › Medicine › Clinical Neurology › Botulinum Toxin and Related Neurological Disorders
Keywords
deep brain stimulation, essential tremor, thalamus, lead positioning, fluoroscopy, long-term efficacy, disease progression, tremor rating scale
MeSH terms
Aged, Female, Follow-Up Studies, Humans, Male, Medical Records, Middle Aged, Postoperative Complications, Treatment Outcome, Essential Tremor, Ventral Thalamic Nuclei, Deep Brain Stimulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Factors involved in long-term efficacy of deep brain stimulation of the thalamus for essential tremor: Clinical article. https://app.cochat.ai/papers/10.3171/jns/2008/109/10/0640
The paper
Pilitsis, J. G., Metman, L. V., Toleikis, J. R., Hughes, L. E., Sani, S. B., & Bakay, R. A. E. (2008). Factors involved in long-term efficacy of deep brain stimulation of the thalamus for essential tremor: Clinical article. Journal of Neurosurgery. https://doi.org/10.3171/jns/2008/109/10/0640

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.