Online Tremor Suppression Using Electromyography and Low-Level Electrical Stimulation
Open accessThe DOI matches its Crossref record; 41 of the 42 references it cites were found in a registry or an index.
Abstract
Tremor is one of the most prevalent movement disorders. There is a large proportion of patients (around 25%) in whom current treatments do not attain a significant tremor reduction. This paper proposes a tremor suppression strategy that detects tremor from the electromyographic signals of the muscles from which tremor originates and counteracts it by delivering electrical stimulation to the antagonist muscles in an out of phase manner. The detection was based on the iterative Hilbert transform and stimulation was delivered above the motor threshold (motor stimulation) and below the motor threshold (sensory stimulation). The system was tested on six patients with predominant wrist flexion/extension tremor (four with Parkinson disease and two with Essential tremor) and led to an average tremor reduction in the range of 46%-81% and 35%-48% across five patients when using the motor and sensory stimulation, respectively. In one patient, the system did not attenuate tremor. These results demonstrate that tremor attenuation might be achieved by delivering electrical stimulation below the motor threshold, preventing muscle fatigue and discomfort for the patients, which sets the basis for the development of an alternative treatment for tremor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“They tested this electrode using the same protocol as in (68) in one PD patient following the out-of-phase electrical sensory stimulation strategy. The patient showed an average tremor angle reduction of 58%, in the same attenuation range reported in their previous study.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [68]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Sensory stimulation resulted in an average tremor suppression of 42.0 ± 5.0%; although lower than that yielded with motor stimulation, it was postulated as a feasible alternative for tremor management (68).”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [68]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A significant limitation we encountered in most of the studies was that the effectiveness of tremor suppression based on the metrics mentioned above was mainly based on trials with a short duration of time. For example, the experimental trial duration in (76) was only 15 s, or if longer trials were used as in (44, 68), the authors divided them into epochs. This methodology tried to cope with the”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [68]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Another recent approach for FES involves stimulating below the motor threshold to mitigate the issue of fatigue [4, 28].”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [28]
The cited source says what the claim attributes to it.
In the citing paper
“Of the above systems, several were demonstrated with individuals with tremor [17–20, 27–32] resulting in ~ 20–88% tremor attenuation levels”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [28]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
Consensus statement of the Movement Disorder Society on Tremor. Ad Hoc Scientific Committee.
Deuschl, G., Bain, P., & Brin, M. (1998) · UCL Discovery (University College London) · Cited by 403
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 2×
“There are several methods to treat tremor: pharmacotherapy [3], neurosurgery [4], deep brain stimulation [5], mechanical loading, and robotics exoskeletons [6].”
BackgroundMethodSelf-citationCurrent approaches to the treatment of Parkinson’s disease
Jankovic, J. (2008) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s2006 · Cited by 342 · cited 1×
“Drugs often have side effects [7] and are prone to habituation [8], deep brain stimulators require invasive surgery and increase the risk of brain hemorrhage [9] and/or psychiatric complications [10], while mechanical systems are cumbersome [6] and can interfere with the voluntary movement [11], [12].”
BackgroundWenning, G. K., Kiechl, S., Seppi, K., Müller, J., Högl, B., Saletu, M., Rungger, G., Gasperi, A., Willeit, J., & Poewe, W. (2005) · The Lancet Neurology · doi:10.1016/s1474-4422(05)70226-x · Cited by 302 · cited 1×
“Pathological tremor is considered the most prevalent movement disorder [2].”
BackgroundPharmacotherapy of Essential Tremor: An Overview of Existing and Upcoming Agents
Lyons, K. E., & Pahwa, R. (2008) · CNS Drugs · doi:10.2165/0023210-200822120-00006 · Cited by 235 · cited 1×
“There are several methods to treat tremor: pharmacotherapy [3], neurosurgery [4], deep brain stimulation [5], mechanical loading, and robotics exoskeletons [6].”
MethodBergquist, A. J., Clair, J. M., & Collins, D. F. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01103.2010 · Cited by 173
Gamma knife thalamotomy for essential tremor
Kondziolka, D., Ong, J. G., Lee, J. Y. K., Moore, R. Y., Flickinger, J. C., & Lunsford, L. D. (2008) · Journal of Neurosurgery · doi:10.3171/jns/2008/108/01/0111 · Cited by 164 · cited 1×
“There are several methods to treat tremor: pharmacotherapy [3], neurosurgery [4], deep brain stimulation [5], mechanical loading, and robotics exoskeletons [6].”
MethodAttenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 3×
“As in the majority of previous tremor suppression studies based on FES [15], [16], [19] the stimulation was delivered out of phase with the estimated tremorogenic activity.”
BackgroundResultDeep brain stimulation for Parkinsonʼs disease and other movement disorders
Kalia, S. K., Sankar, T., & Lozano, A. M. (2013) · Current Opinion in Neurology · doi:10.1097/wco.0b013e3283632d08 · Cited by 147 · cited 1×
“There are several methods to treat tremor: pharmacotherapy [3], neurosurgery [4], deep brain stimulation [5], mechanical loading, and robotics exoskeletons [6].”
Method
Research works printed but not linked: 1
- b, 2000, Neuro Muscular Electrical Stimulation A Practical Guide
Cited by
Bioelectronics for electrical stimulation: materials, devices and biomedical applications
Huang, Y., Yao, K., Zhang, Q., Huang, X., Chen, Z., Zhou, Y., & Yu, X. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00413b · Cited by 183
Electrical stimulation of afferent pathways for the suppression of pathological tremor
Dideriksen, J. L., Laine, C. M., Dosen, S., Muceli, S., Rocon, E., Pons, J. L., Benito-Leon, J., & Farina, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00178 · Cited by 67
Self-citationMedical Devices for Tremor Suppression: Current Status and Future Directions
Mo, J., & Priefer, R. (2021) · Biosensors · doi:10.3390/bios11040099 · Cited by 78
Peripheral electrical stimulation to reduce pathological tremor: a review
Pascual-Valdunciel, A., Hoo, G. W., Avrillon, S., Barroso, F. O., Goldman, J. G., Hernandez-Pavon, J. C., & Pons, J. L. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00811-9 · Cited by 66
“EMG-based algorithms have been used to drive the out-of-phase stimulation strategy, using sequential recording and stimulation windows to avoid the presence of artifacts in the EMG recordings [16, 36, 42].”
BackgroundMethodInfluentialSelf-citationA Review on Wearable Technologies for Tremor Suppression
Lora-Millan, J. S., Delgado-Oleas, G., Benito-León, J., & Rocon, E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.700600 · Cited by 62
“For example, the experimental trial duration in (76) was only 15 s, or if longer trials were used as in (44, 68), the authors divided them into epochs.”
BackgroundMethodInfluential
Metadata
- Authors
- Dosen, S., Muceli, S., Dideriksen, J. L., Romero, J. P., Rocon, E., Pons, J., & Farina, D.
- Affiliations
- Universitätsmedizin Göttingen (DE)
- Hospital Universitario 12 De Octubre (ES)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2015-05
- Volume
- 23
- Issue
- 3
- Pages
- 385-395
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2089911350
- Cited by
- 120
- References
- 42
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 15 · 2023: 15 · 2022: 13 · 2021: 13 · 2020: 6 · 2019: 15 · 2018: 9 · 2017: 11 · 2016: 5 · 2015: 6
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion, other-oa)
- GRO (submittedVersion)
- Chalmers Research (Chalmers University of Technology) (submittedVersion)
- Spiral (Imperial College London) (submittedVersion)
- Funders
- Commission of the European Union (ICT-2011-287739)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- tremor suppression, electromyography, electrical stimulation, Hilbert transform, motor threshold, sensory stimulation, motor stimulation, Parkinson's disease, essential tremor, movement disorders
- MeSH terms
- Aged, Electromyography, Electric Stimulation Therapy, Female, Humans, Male, Middle Aged, Online Systems, Parkinson Disease, Sensory Thresholds, Tremor, Treatment Outcome, Muscle, Skeletal, Muscle Fatigue, Essential Tremor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Online Tremor Suppression Using Electromyography and Low-Level Electrical Stimulation. https://app.cochat.ai/papers/10.1109/tnsre.2014.2328296
- The paper
- Dosen, S., Muceli, S., Dideriksen, J. L., Romero, J. P., Rocon, E., Pons, J., & Farina, D. (2015). Online Tremor Suppression Using Electromyography and Low-Level Electrical Stimulation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2014.2328296
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.