CoChat

Methods for implantation of micro-wire bundles and optimization of single/multi-unit recordings from human mesial temporal lobe

Open access
Misra, A, Burke, J F, Ramayya, A G, Jacobs, J, Sperling, M R, Moxon, K A, Kahana, M J, Evans, J J, Sharan, A D · 2014 · Journal of Neural Engineering
Cited by 66

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The authors report methods developed for the implantation of micro-wire bundles into mesial temporal lobe structures and subsequent single neuron recording in epileptic patients undergoing in-patient diagnostic monitoring. This is done with the intention of lowering the perceived barriers to routine single neuron recording from deep brain structures in the clinical setting. APPROACH: Over a 15 month period, 11 patients were implanted with platinum micro-wire bundles into mesial temporal structures. Protocols were developed for (A) monitoring electrode integrity through impedance testing, (B) ensuring continuous 24-7 recording, (C) localizing micro-wire position and 'splay' pattern and (D) monitoring grounding and referencing to maintain the quality of recordings. MAIN RESULTS: Five common modes of failure were identified: (1) broken micro-wires from acute tensile force, (2) broken micro-wires from cyclic fatigue at stress points, (3) poor in vivo micro-electrode separation, (4) motion artifact and (5) deteriorating ground connection and subsequent drop in common mode noise rejection. Single neurons have been observed up to 14 days post-implantation and on 40% of micro-wires. SIGNIFICANCE: Long-term success requires detailed review of each implant by both the clinical and research teams to identify failure modes, and appropriate refinement of techniques while moving forward. This approach leads to reliable unit recordings without prolonging operative times, which will help increase the availability and clinical viability of human single neuron data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2560/11/2/026013

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 66

Metadata

Authors
Misra, A., Burke, J. F., Ramayya, A. G., Jacobs, J., Sperling, M. R., Moxon, K. A., Kahana, M. J., Evans, J. J., & Sharan, A. D.
Venue
Journal of Neural Engineering
Published
2014-03-10
Volume
11
Issue
2
Pages
026013
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2161357355
Cited by
66
References
4
FWCI
1.34
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Methods for implantation of micro-wire bundles and optimization of single/multi-unit recordings from human mesial temporal lobe. https://app.cochat.ai/papers/10.1088/1741-2560/11/2/026013
The paper
Misra, A., Burke, J. F., Ramayya, A. G., Jacobs, J., Sperling, M. R., Moxon, K. A., Kahana, M. J., Evans, J. J., & Sharan, A. D. (2014). Methods for implantation of micro-wire bundles and optimization of single/multi-unit recordings from human mesial temporal lobe. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/11/2/026013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.