Methods for implantation of micro-wire bundles and optimization of single/multi-unit recordings from human mesial temporal lobe
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The authors report methods developed for the implantation of micro-wire bundles into mesial temporal lobe structures and subsequent single neuron recording in epileptic patients undergoing in-patient diagnostic monitoring. This is done with the intention of lowering the perceived barriers to routine single neuron recording from deep brain structures in the clinical setting. APPROACH: Over a 15 month period, 11 patients were implanted with platinum micro-wire bundles into mesial temporal structures. Protocols were developed for (A) monitoring electrode integrity through impedance testing, (B) ensuring continuous 24-7 recording, (C) localizing micro-wire position and 'splay' pattern and (D) monitoring grounding and referencing to maintain the quality of recordings. MAIN RESULTS: Five common modes of failure were identified: (1) broken micro-wires from acute tensile force, (2) broken micro-wires from cyclic fatigue at stress points, (3) poor in vivo micro-electrode separation, (4) motion artifact and (5) deteriorating ground connection and subsequent drop in common mode noise rejection. Single neurons have been observed up to 14 days post-implantation and on 40% of micro-wires. SIGNIFICANCE: Long-term success requires detailed review of each implant by both the clinical and research teams to identify failure modes, and appropriate refinement of techniques while moving forward. This approach leads to reliable unit recordings without prolonging operative times, which will help increase the availability and clinical viability of human single neuron data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering
Quiroga, R. Q., Nadasdy, Z., & Ben-Shaul, Y. (2004) · Neural Computation · doi:10.1162/089976604774201631 · Cited by 2,119
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · cited 2×
“Failing this, it remains possible to record multi-unit activity (MUA) from the collection of cells in a somewhat larger neighborhood around the recording site [17, 18].”
BackgroundNeural syntax: cell assemblies, synapsembles, and readers
Buzsáki, G. (2010) · Neuron · doi:10.1016/j.neuron.2010.09.023 · Cited by 1,289
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640 · cited 1×
“While numerous studies have employed either multielectrode arrays (cortical recordings) [4] or micro-wire bundles (mesial structure recordings) [5–8] to record single neuron activity in humans, few provide specific methodological details about the required troubleshooting approaches for successful recordings, especial…”
Background
Cited by
Large-scale neural recordings with single neuron resolution using Neuropixels probes in human cortex
Paulk, A. C., Kfir, Y., Khanna, A. R., Mustroph, M. L., Trautmann, E. M., Soper, D. J., Stavisky, S. D., Welkenhuysen, M., Dutta, B., Shenoy, K. V., et al. (2022) · Nature Neuroscience · doi:10.1038/s41593-021-00997-0 · Cited by 283
High-frequency oscillations in epilepsy and surgical outcome. A meta-analysis
Höller, Y., Kutil, R., Klaffenböck, L., Thomschewski, A., Höller, P. M., Bathke, A. C., Jacobs, J., Taylor, A. C., Nardone, R., & Trinka, E. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00574 · Cited by 165
“The use of micro-electrodes is limited to multielectrode arrays or micro-wire bundles for mesial structures (Misra et al., 2014).”
Self-citationHigh-density single-unit human cortical recordings using the Neuropixels probe
Chung, J. E., Sellers, K. K., Leonard, M. K., Gwilliams, L., Xu, D., Dougherty, M. E., Kharazia, V., Metzger, S. L., Welkenhuysen, M., Dutta, B., et al. (2022) · Neuron · doi:10.1016/j.neuron.2022.05.007 · Cited by 126
The Argo: a high channel count recording system for neural recording in vivo
Sahasrabuddhe, K., Khan, A. A., Singh, A. P., Stern, T. M., Ng, Y., Tadić, A., Orel, P., LaReau, C., Pouzzner, D., Nishimura, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd0ce · Cited by 124
Pothof, F., Bonini, L., Lanzilotto, M., Livi, A., Fogassi, L., Orban, G. A., Paul, O., & Ruther, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046006 · Cited by 56
“Cross-sections of (a) a conventional SEEG probe comprising hollow metal cylinders spot-welded to micro wires and insulating modules, (b) an advanced SEEG probe with larger diameter containing additional movable Behnke-Fried microelectrodes integrated in the hollow probe body (on the basis of [12]), (c) and micro conta…”
Background
Metadata
- Authors
- Misra, A., Burke, J. F., Ramayya, A. G., Jacobs, J., Sperling, M. R., Moxon, K. A., Kahana, M. J., Evans, J. J., & Sharan, A. D.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-03-10
- Volume
- 11
- Issue
- 2
- Pages
- 026013
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2161357355
- Cited by
- 66
- References
- 4
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methods for implantation of micro-wire bundles and optimization of single/multi-unit recordings from human mesial temporal lobe. https://app.cochat.ai/papers/10.1088/1741-2560/11/2/026013
- The paper
- Misra, A., Burke, J. F., Ramayya, A. G., Jacobs, J., Sperling, M. R., Moxon, K. A., Kahana, M. J., Evans, J. J., & Sharan, A. D. (2014). Methods for implantation of micro-wire bundles and optimization of single/multi-unit recordings from human mesial temporal lobe. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/11/2/026013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.