Chronic neural probe for simultaneous recording of single-unit, multi-unit, and local field potential activity from multiple brain sites
Open accessAbstract
OBJECTIVE: Drug resistant focal epilepsy can be treated by resecting the epileptic focus requiring a precise focus localisation using stereoelectroencephalography (SEEG) probes. As commercial SEEG probes offer only a limited spatial resolution, probes of higher channel count and design freedom enabling the incorporation of macro and microelectrodes would help increasing spatial resolution and thus open new perspectives for investigating mechanisms underlying focal epilepsy and its treatment. This work describes a new fabrication process for SEEG probes with materials and dimensions similar to clinical probes enabling recording single neuron activity at high spatial resolution. APPROACH: Polyimide is used as a biocompatible flexible substrate into which platinum electrodes and leads are integrated with a minimal feature size of 5 μm. The polyimide foils are rolled into the cylindrical probe shape at a diameter of 0.8 mm. The resulting probe features match those of clinically approved devices. Tests in saline solution confirmed the probe stability and functionality. Probes were implanted into the brain of one monkey (Macaca mulatta), trained to perform different motor tasks. Suitable configurations including up to 128 electrode sites allow the recording of task-related neuronal signals. MAIN RESULTS: Probes with 32 and 64 electrode sites were implanted in the posterior parietal cortex. Local field potentials and multi-unit activity were recorded as early as one hour after implantation. Stable single-unit activity was achieved for up to 26 days after implantation of a 64-channel probe. All recorded signals showed modulation during task execution. SIGNIFICANCE: With the novel probes it is possible to record stable biologically relevant data over a time span exceeding the usual time needed for epileptic focus localisation in human patients. This is the first time that single units are recorded along cylindrical polyimide probes chronically implanted 22 mm deep into the brain of a monkey, which suggests the potential usefulness of this probe for human applications.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Pothof et al. (2016) described fabrication of a chronic neural probe with similar material and geometrical properties to clinical probes that enables recording of single neuron activity at high spatial resolution.
“Most recent study by Pothof et al. (2016) described the fabrication process of a chronic neural probe that has similar material and geometrical properties with that of clinical probes that enable recording of a single neuron activity at a high spatial resolution.”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Pothof et al. (2016)
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Single-Neuron Responses in Humans during Execution and Observation of Actions
Mukamel, R., Ekstrom, A. D., Kaplan, J., Iacoboni, M., & Fried, I. (2010) · Current Biology · doi:10.1016/j.cub.2010.02.045 · Cited by 1,178 · see citing works
Bilateral deep brain stimulation in Parkinson's disease: a multicentre study with 4 years follow-up.
Rodríguez-Oroz, M., Obeso, J., Lang, A., Houeto, J., Pollak, P., Rehncrona, S., Kulisevsky, J., Albanese, A., Volkmann, J., Hariz, M., et al. (2005) · Brain : a journal of neurology · doi:10.1093/brain/awh571 · Cited by 1,120 · see citing works
Single Neuron Activity in Human Hippocampus and Amygdala during Recognition of Faces and Objects
Fried, I., Macdonald, K., & Wilson, C. L. (1997) · Neuron · doi:10.1016/s0896-6273(00)80315-3 · Cited by 542 · see citing works
Single-neuron dynamics in human focal epilepsy
Truccolo, W., Donoghue, J., Hochberg, L. R., Eskandar, E. N., Madsen, J. R., Anderson, W. S., Brown, E. N., Halgren, E., & Cash, S. S. (2011) · Nature Neuroscience · doi:10.1038/nn.2782 · Cited by 516 · see citing works
Worrell, G. A., Gardner, A. B., Stead, S. M., Hu, S., Goerss, S., Cascino, G. J., Meyer, F. B., Marsh, R. W., & Litt, B. (2008) · Brain · doi:10.1093/brain/awn006 · Cited by 455 · see citing works
Picot, M., Baldy-Moulinier, M., Daurès, J., Dujols, P., & Crespel, A. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01579.x · Cited by 453 · see citing works
A MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387 · see citing works
Single-neuron responses to emotional visual stimuli recorded in human ventral prefrontal cortex
Kawasaki, H., Adolphs, R., Kaufman, O., Damásio, H., Damásio, A. R., Granner, M. A., Bakken, H. E., Hori, T., & Howard, M. A. (2001) · Nature Neuroscience · doi:10.1038/82850 · Cited by 367 · see citing works
Tourette's syndrome and deep brain stimulation
Houéto, J. (2005) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2004.043273 · Cited by 347 · see citing works
Rozzi, S., Ferrari, P. F., Bonini, L., Rizzolatti, G., & Fogassi, L. (2008) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2008.06395.x · Cited by 343 · see citing works
Self-citationMicromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · see citing works
Cossu, M., Cardinale, F., Castana, L., Citterio, A., Francione, S., Tassi, L., Benabid, A. L., & Russo, G. L. (2005) · Neurosurgery · doi:10.1227/01.neu.0000176656.33523.1e · Cited by 332 · see citing works
The Scalable Brain Atlas: Instant Web-Based Access to Public Brain Atlases and Related Content
Bakker, R., Tiesinga, P. H. E., & Kötter, R. (2015) · Neuroinformatics · doi:10.1007/s12021-014-9258-x · Cited by 298 · see citing works
Laminar analysis of slow wave activity in humans
Csercsa, R., Dombovári, B., Fabó, D., Wittner, L., Erőss, L., Entz, L., Sólyom, A., Rásonyi, G., Szűcs, A., Kelemen, A., et al. (2010) · Brain · doi:10.1093/brain/awq169 · Cited by 239 · see citing works
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207 · see citing works
Bonini, L., Maranesi, M., Livi, A., Fogassi, L., & Rizzolatti, G. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.4187-13.2014 · Cited by 121 · see citing works
Self-citationFour-dimensional maps of the human somatosensory system
Avanzini, P., Abdollahi, R. O., Sartori, I., Caruana, F., Pelliccia, V., Casaceli, G., Mai, R., Lo Russo, G., Rizzolatti, G., & Orban, G. A. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601889113 · Cited by 114 · see citing works
Self-citationHerwik, S., Kisban, S., Aarts, A. A. A., Seidl, K., Girardeau, G., Benchenane, K., Zugaro, M. B., Wiener, S. I., Paul, O., Neves, H. P., et al. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/7/074008 · Cited by 113 · see citing works
Self-citationWishart, H. A. (2003) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.74.10.1392 · Cited by 94 · see citing works
Maranesi, M., Rodà, F., Bonini, L., Rozzi, S., Ferrari, P. F., Fogassi, L., & Coudé, G. (2012) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2012.08252.x · Cited by 69 · see citing works
Self-citationSeidl, K., Herwik, S., Torfs, T., Neves, H. P., Paul, O., & Ruther, P. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2167661 · Cited by 68 · see citing works
Self-citationMisra, A., Burke, J. F., Ramayya, A. G., Jacobs, J., Sperling, M. R., Moxon, K. A., Kahana, M. J., Evans, J., & Sharan, A. D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026013 · Cited by 64 · see citing works
Single-unit activities during epileptic discharges in the human hippocampal formation
Alvarado‐Rojas, C., Lehongre, K., Bagdasaryan, J., Bragin, A., Staba, R. J., Engel, J., Navarro, V., & Quyen, M. L. V. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00140 · Cited by 61 · see citing works
Kisban, S., Herwik, S., Seidl, K., Rubehn, B., Jezzini, A., Umiltà, M. A., Fogassi, L., Stieglitz, T., Paul, O., & Ruther, P. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352251 · Cited by 55 · see citing works
Self-citationGompel, J. J. V., Stead, S. M., Giannini, C., Meyer, F. B., Marsh, W. R., Fountain, T., So, E. L., Cohen‐Gadol, A., Lee, K. H., & Worrell, G. A. (2008) · Neurosurgical FOCUS · doi:10.3171/foc/2008/25/9/e23 · Cited by 53 · see citing works
Ulbert, I. (2004) · Experimental Neurology · doi:10.1016/j.expneurol.2003.12.003 · Cited by 36 · see citing works
The Preoperative Evaluation and Surgical Treatment of Epilepsy
Schulze‐Bonhage, A., & Zentner, J. (2014) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2014.0313 · Cited by 36 · see citing works
Flexible miniature ribbon cables for long‐term connection to implantable sensors
Hetke, J. F., Najafi, K., & Wise, K. D. (1990) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(90)87076-u · Cited by 33 · see citing works
Safety of Hybrid Electrodes for Single-Neuron Recordings in Humans
Hefft, S., Brandt, A., Zwick, S., von Elverfeldt, D., Mader, I., Cordeiro, J. G., Trippel, M., Blumberg, J., & Schulze‐Bonhage, A. (2013) · Neurosurgery · doi:10.1227/01.neu.0000429840.76460.8c · Cited by 30 · see citing works
Bonini, L., Maranesi, M., Livi, A., Bruni, S., Fogassi, L., Holzhammer, T., Paul, O., & Ruther, P. (2012) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2012-0099 · Cited by 24 · see citing works
Self-citationLed-based optical cochlear implant on highly flexible triple layer polyimide substrates
Schwaerzle, M., Nehlich, J., Ayub, S., Paul, O., & Ruther, P. (2016) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2016.7421644 · Cited by 24 · see citing works
Self-citationMultimodal Encoding of Goal-Directed Actions in Monkey Ventral Premotor Grasping Neurons
Bruni, S., Giorgetti, V., Fogassi, L., & Bonini, L. (2015) · Cerebral Cortex · doi:10.1093/cercor/bhv246 · Cited by 17 · see citing works
Self-citationSchwaerzle, M., Pothof, F., Paul, O., & Ruther, P. (2015) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2015.7181290 · Cited by 15 · see citing works
Self-citationCylindrical Cochlear Electrode Array for Use in Humans
van der Puije, P. D., Pon, C. R., & Robillard, H. (1989) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948909800614 · Cited by 14 · see citing works
Pothof, F., Anees, S., Leupold, J., Bonini, L., Paul, O., Orban, G. A., & Ruther, P. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944808 · Cited by 13 · see citing works
Self-citationFomani, A. A., Mansour, R. R., Florez, C. M., & Carlen, P. L. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2160934 · Cited by 12 · see citing works
Flagged first, then by citations
Research works printed but not linked: 4
- [2][2] J.M. Scarabin. Stereotaxy and Epilepsy Surgery - With videos (English and French Edition) . John Libbey Eurotext ltd, 2012. -
- [6][6] H.S. Mayberg, A.M. Lozano, V. Voon, H.E. McNeely, D. Seminowicz, C. Hamani, J.M. Schwalb, and S.H. Kennedy. Deep brain stimulation for treatment-resistant depression. Neuron , 45(5):651 - 660, 2005. -
- [29][29] D.T.T. Plachta, M. Gierthmuehlen, O. Cota, N. Espinosa, F. Boeser, T.C. Herrera, T. Stieglitz, and J. Zentner. Blood pressure control with selective vagal nerve stimulation and minimal side effects. J. Neural Eng. , 11(3):036011, 2014. -
- [36][36] J.S. Ordonez, C. Boehler, M. Schuettler, and T. Stieglitz. Long-term adhesion studies of polyimide to inorganic and metallic layers. In Symposium TT Interfaces in Materials, Biol. and Phys. , volume 1466 of MRS Proceedings , 2012. -
Cited by
Sorted by citations
Advances in human intracranial electroencephalography research, guidelines and good practices
Mercier, M. R., Dubarry, A., Tadel, F., Avanzini, P., Axmacher, N., Cellier, D., Vecchio, M. D., Hamilton, L. S., Hermes, D., Kahana, M. J., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119438 · Cited by 236 · see citing works
Herff, C., Krusienski, D. J., & Kubben, P. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00123 · Cited by 115 · see citing works
Sensor Modalities for Brain-Computer Interface Technology: A Comprehensive Literature Review
Martini, M. L., Oermann, E. K., Opie, N. L., Panov, F. E., Oxley, T. J., & Yaeger, K. (2019) · Neurosurgery · doi:10.1093/neuros/nyz286 · Cited by 117 · see citing works
The future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115 · see citing works
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88 · see citing works
“Most recent study by Pothof et al. (2016) described the fabrication process of a chronic neural probe that has similar material and geometrical properties with that of clinical probes that enable recording of a single neuron activity at a high spatial resolution.”
Dorigo, D. D., Moranz, C., Graf, H., Marx, M., Wendler, D., Shui, B., Herbawi, A. S., Kuhl, M., Ruther, P., Paul, O., et al. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2873180 · Cited by 94 · see citing works
Self-citationA comparison of insertion methods for surgical placement of penetrating neural interfaces
Thielen, B., & Meng, E. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf6f2 · Cited by 72 · see citing works
Bastuji, H., Frot, M., Perchet, C., Hagiwara, K., & Garcı́a-Larrea, L. (2018) · Scientific Reports · doi:10.1038/s41598-018-31781-z · Cited by 66 · see citing works
Translational Neuroelectronics
Jastrzebska‐Perfect, P., Chowdhury, S., Spyropoulos, G. D., Zhao, Z., Cea, C., Gelinas, J. N., & Khodagholy, D. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909165 · Cited by 64 · see citing works
Flexible, scalable, high channel count stereo-electrode for recording in the human brain
Lee, K., Paulk, A. C., Ro, Y. G., Cleary, D. R., Tonsfeldt, K. J., Kfir, Y., Pezaris, J. S., Tchoe, Y., Lee, J., Bourhis, A. M., et al. (2024) · Nature Communications · doi:10.1038/s41467-023-43727-9 · Cited by 67 · see citing works
An Attention-Based Spiking Neural Network for Unsupervised Spike-Sorting
Bernert, M., & Yvert, B. (2018) · International Journal of Neural Systems · doi:10.1142/s0129065718500594 · Cited by 64 · see citing works
Giagka, V., & Serdijn, W. A. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0010-y · Cited by 58 · see citing works
A Single-Neuron: Current Trends and Future Prospects
Gupta, P., Balasubramaniam, N., Chang, H., Tseng, F., & Santra, T. S. (2020) · Cells · doi:10.3390/cells9061528 · Cited by 49 · see citing works
Flexible, high-resolution thin-film electrodes for human and animal neural research
Chiang, C., Wang, C., Barth, K. J., Rahimpour, S., Trumpis, M., Duraivel, S., Rachinskiy, I., Dubey, A., Wingel, K., Wong, M. K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac02dc · Cited by 45 · see citing works
Current and emerging strategies for biocompatible materials for implantable electronics
Zhou, Y., Morris, G. H. B., & Nair, M. (2024) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2024.101852 · Cited by 42 · see citing works
Flexible deep brain neural probe for localized stimulation and detection with metal guide
Kim, J. H., Lee, G. H., Kim, S., Chung, H. W., Lee, J. H., Lee, S. M., Kang, C. Y., & Lee, S. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.035 · Cited by 39 · see citing works
An Ultraflexible Electrode Array for Large‐Scale Chronic Recording in the Nonhuman Primate Brain
Tian, Y., Yin, J., Wang, C., He, Z., Xie, J., Feng, X., Zhou, Y., Ma, T., Xie, Y., Li, X., et al. (2023) · Advanced Science · doi:10.1002/advs.202302333 · Cited by 31 · see citing works
Vatsyayan, R., Lee, J., Bourhis, A. M., Tchoe, Y., Cleary, D. R., Tonsfeldt, K. J., Lee, K., Montgomery‐Walsh, R., Paulk, A. C., Hoi Sang, U., et al. (2023) · MRS Bulletin · doi:10.1557/s43577-023-00537-0 · Cited by 25 · see citing works
Fiáth, R., Hofer, K. T., Csikós, V., Horváth, D., Nánási, T., Tóth, K., Pothof, F., Böhler, C., Asplund, M., Ruther, P., et al. (2018) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2017-0154 · Cited by 24 · see citing works
Self-citationKim, C., Jeong, J., & Kim, S. J. (2019) · Sensors · doi:10.3390/s19051069 · Cited by 22 · see citing works
Flexible deep brain neural probes based on a parylene tube structure
Zhao, Z., Kim, E. H., Luo, H., Zhang, J., & Xu, Y. P. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa9d61 · Cited by 20 · see citing works
Yi, D., Yao, Y., Wang, Y., & Chen, L. (2022) · Journal of Micro and Nano-Manufacturing · doi:10.1115/1.4063179 · Cited by 23 · see citing works
System for recording from multiple flexible polyimide neural probes in freely behaving animals
van Daal, R. J. J., Sun, J.-J., Ceyssens, F., Michon, F., Kraft, M., Puers, R., & Kloosterman, F. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5e19 · Cited by 18 · see citing works
Advances in Implantable Microelectrode Array Insertion and Positioning
Atkinson, D., D'Souza, T. M., Rajput, J. S., Tasnim, N., Muthuswamy, J., Marvi, H., & Pancrazio, J. J. (2021) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.13355 · Cited by 16 · see citing works
Flexible neural probes: a review of the current advantages, drawbacks, and future demands
Pimenta, S., Freitas, J. R., & Correia, J. H. (2024) · Journal of Zhejiang University SCIENCE B · doi:10.1631/jzus.b2300337 · Cited by 16 · see citing works
Sellers, K. K., Chung, J. E., Zhou, J. J., Triplett, M., Dawes, H. E., Haque, R., & Chang, E. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1984 · Cited by 15 · see citing works
Sensing local field potentials with a directional and scalable depth electrode array
Abrego, A. M., Khan, W., Wright, C. E., Islam, M. R., Ghajar, M. H., Bai, X., Tandon, N., & Seymour, J. P. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acb230 · Cited by 15 · see citing works
Horváth, C., Csikós, K., Árkossy, B., Klein, E., Ruther, P., Ulbert, I., & Fiáth, R. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136220 · Cited by 12 · see citing works
Self-citationElectrode Arrays for Detecting and Modulating Deep Brain Neural Information in Primates: A Review
Zhang, S., Song, Y., Lv, S., Jing, L., Wang, M., Liu, Y., Xu, W., Jiao, P., Zhang, S., Wang, M., et al. (2025) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0249 · Cited by 15 · see citing works
Wang, M., Nikaido, K., Kim, Y., Ji, B., Tian, H., Kang, X., Yang, C., Yang, B., Chen, X., Wang, X., et al. (2017) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2017.7863453 · Cited by 12 · see citing works
High‐Resolution Recording of Neural Activity in Epilepsy Using Flexible Neural Probes
Cheng, Q., Li, G., Tian, Y., Wang, H., Ye, Y., Zhou, C., Xu, C., Nie, Y., Yang, H., Zhou, Z., et al. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202301210 · Cited by 10 · see citing works
Gerbella, M., Borra, E., Pothof, F., Lanzilotto, M., Livi, A., Fogassi, L., Paul, O., Orban, G. A., Ruther, P., & Bonini, L. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abdd11 · Cited by 9 · see citing works
Self-citationExtreme manufacturing of minimally invasive intracortical neural electrodes
Xu, M., Zhu, Z., Ma, H., Zhou, G., Iliasov, A., Chen, Z., Tsang, W. M., Wu, J., Li, C., Wei, X., et al. (2025) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ae2579 · Cited by 8 · see citing works
Flexible Electronics for Monitoring in vivo Electrophysiology and Metabolite Signals
Choi, H. K., Lee, J., Lee, T., Lee, S.-N., & Choi, J. (2020) · Frontiers in Chemistry · doi:10.3389/fchem.2020.547591 · Cited by 8 · see citing works
Proof of Concept for Sustainable Manufacturing of Neural Electrode Array for In Vivo Recording
Li, S.-Y., Tseng, H.-Y., Chen, B., Lo, Y., Shao, H.-H., Wu, Y.-T., Li, S., Chang, C.-W., Liu, T., Hsieh, F.-Y., et al. (2023) · Biosensors · doi:10.3390/bios13020280 · Cited by 7 · see citing works
Biological and Mechanical Limitations for Chronic Fast‐Scan Cyclic Voltammetry Sensor Design
Perillo, M. L., Gupta, B., Saxena, A., Veltri, A. P., Li, W., Siegenthaler, J. R., & Purcell, E. K. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202401808 · Cited by 7 · see citing works
High-density Steeltrodes: A Novel Platform for High Resolution Recording in Primates
Ahmed, Z., Reddy, J. W., Teichert, T., & Chamanzar, M. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716921 · Cited by 5 · see citing works
Long-term evaluation and feasibility study of the insulated screw electrode for ECoG recording
Choi, H., Lee, S., Lee, J., Min, K., Lim, S., Park, J., Ahn, K.-H., Kim, I. Y., Lee, K., & Jang, D. P. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.06.027 · Cited by 5 · see citing works
Fully unsupervised online spike sorting based on an artificial spiking neural networkPreprint
Bernert, M., & Yvert, B. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/236224 · Cited by 5 · see citing works
Comparison of the in-vivo neural recording quality of floating and skull-fixed silicon probes
Pothof, F., Chauvière, L., Holzhammer, T., Aarts, A. A. A., Paul, O., Singer, W., & Ruther, P. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008316 · Cited by 4 · see citing works
Self-citationLarge-scale single-neuron recording in the human cortex using an ultra-flexible electrode array
Wu, S. P., Yan, Z., Kong, C., Jiang, X., Dong, Q., Qian, Y., Chen, G., Chen, B., Ren, C., Lu, J., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-71443-7 · Cited by 3 · see citing works
Hoch, K., Pothof, F., Becker, F., Paul, O., & Ruther, P. (2018) · Micromachines · doi:10.3390/mi9090424 · Cited by 3 · see citing works
Self-citationFlexible, Scalable, High Channel Count Stereo-Electrode for Recording in the Human BrainPreprint
Lee, K., Paulk, A. C., Ro, Y. G., Cleary, D. R., Tonsfeldt, K. J., Kfir, Y., Pezaris, J. S., Tchoe, Y., Lee, J., Bourhis, A. M., et al. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.11.08.515705 · Cited by 3 · see citing works
Modeling task-specific neuronal ensembles improves decoding of grasp
Smith, R. J., Soares, A. B., Rouse, A. G., Schieber, M. H., & Thakor, N. V. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaac93 · Cited by 2 · see citing works
Flexible MRI Compatible Brain Probes
Ahmadi, M., Cruttenden, C. E., Zhu, X. H., Chen, W., & Rajamani, R. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513162 · Cited by 2 · see citing works
Recent Advancements in Bioelectronic Medicine: A Review
Das, S., Ghosh, B., Sahoo, R. N., & Nayak, A. K. (2024) · Current Drug Delivery · doi:10.2174/0115672018286832231218112557 · Cited by 2 · see citing works
Bioelectronic Medicines-A Novel Approach of Therapeutics in Current Epoch
Kumar, A., Ashawat, M. S., Pandit, V. R., & Kumar, P. (2024) · Current Pharmaceutical Design · doi:10.2174/0113816128326489240827100537 · Cited by 2 · see citing works
Ahmed, Z., Kimukin, Ï., Jain, V., Gurnsey, K., Teichert, T., & Chamanzar, M. (2026) · Nature Communications · doi:10.1038/s41467-025-67681-w · Cited by 1 · see citing works
Repeatable, low-drift recordings in behaving nonhuman primates using flexible microelectrodes
Woods, D. P., Adams, G., Mozumder, R., Dang, W., Chen, A. Y., Chevée, M., Constantinidis, C., & Gonzales, D. L. (2026) · Nature Communications · doi:10.1038/s41467-026-77421-3 · Cited by 2 · see citing works
Large-scale single-neuron recording using the uFINE array in human cortexPreprint
Wu, S. P., Yan, Z., Kong, C., Li, X., Dong, Q., Qian, Y., Chen, G., Chen, B., Ren, C., Lu, J., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.04.14.648657 · Cited by 1 · see citing works
THE DYE INDUSTRY AND PHARMACEUTICALS-HISTORICAL AND CURRENT PERSPECTIVES
Consulting Patent Associate, G. A. L., & Ravi, S. (2026) · INDIAN DRUGS · doi:10.53879/id.63.02.p0005
Aerosol-Jet Printed Electrodes for Neural Recording in Vivo Toward Integration with Imaging Tools
Vokt, K. G., Bai, X., Lim, J., Seymour, J. P., & Kemere, C. T. (2025) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner61569.2025.11588917
Conformal mechanics of serpentine meshes for millimeter-scale neural probes
Batay, S., Zhou, Y., Pathirana, P. V., Seymour, J. P., & Avila, R. O. (2026) · Mechanics of Materials · doi:10.1016/j.mechmat.2026.105860
- Authors
- Pothof, F., Bonini, L., Lanzilotto, M., Livi, A., Fogassi, L., Orban, G. A., Paul, O., & Ruther, P.
- Affiliations
- University of Freiburg (DE)
- Italian Institute of Technology (IT)
- University of Parma (IT)
- Corresponding author
- Pothof, F
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-06-01
- Volume
- 13
- Issue
- 4
- Pages
- 046006
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2419219811
- Cited by
- 56
- References
- 36
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 6 · 2023: 5 · 2022: 3 · 2021: 6 · 2020: 6 · 2019: 4 · 2018: 10 · 2017: 6
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- Institutional Research Information System University of Turin (University of Turin) (submittedVersion)
- arXiv (Cornell University)
- Funders
- European Commission (600925)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- stereoelectroencephalography, polyimide substrate, platinum microelectrodes, multi-unit activity, single-unit recording, local field potentials, focal epilepsy, posterior parietal cortex, monkey model, probe fabrication
- MeSH terms
- Animals, Biocompatible Materials, Brain, Electrodes, Implanted, Electroencephalography, Epilepsies, Partial, Evoked Potentials, Female, Macaca mulatta, Microelectrodes, Neurons, Parietal Lobe
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review