Long-term decoding stability of local field potentials from silicon arrays in primate motor cortex during a 2D center out task
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Many serious concerns exist in the long-term stability of brain-machine interfaces (BMIs) based on spike signals (single unit activity, SUA; multi unit activity, MUA). Some studies showed local field potentials (LFPs) could offer a stable decoding performance. However, the decoding stability of LFPs was examined only when high quality spike signals were recorded. Here we aim to examine the long-term decoding stability of LFPs over a larger time scale when the quality of spike signals was from good to poor or even no spike was recorded. APPROACH: Neural signals were collected from motor cortex of three monkeys via silicon arrays over 230, 290 and 690 days post-implantation when they performed 2D center out task. To compare long-term stability between LFPs and spike signals, we examined them in neural signals characteristics, directional tuning properties and offline decoding performance, respectively. MAIN RESULTS: We observed slow decreasing trends in the number of LFP channels recorded and mean LFP power in different frequency bands when spike signals quality decayed over time. The number of significantly directional tuning LFP channels decreased more slowly than that of tuning SUA and MUA. The variable preferred directions for the same signal features across sessions indicated non-stationarity of neural activity. We also found that LFPs achieved better decoding performance than SUA and MUA in retrained decoder when the quality of spike signals seriously decayed. Especially, when no spike was recorded in one monkey after 671 days post-implantation, LFPs still provided some kinematic information. In addition, LFPs outperformed MUA in long-term decoding stability in a static decoder. SIGNIFICANCE: Our results suggested that LFPs were more durable and could provide better decoding performance when spike signals quality seriously decayed. It might be due to their resistance to recording degradation and their high redundancy among channels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 1×
“Nonstationarity has been observed in many previous studies, where the reorganization of functional properties of neural populations [12], and temporal changes of neuronal tuning properties over time were reported [57–59].”
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Cited by
Nason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113
Christie, B. P., Tat, D. M., Irwin, Z. T., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., Thompson, D. E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016009 · Cited by 103
Robust and accurate decoding of hand kinematics from entire spiking activity using deep learning
Ahmadi, N., Constandinou, T. G., & Bouganis, C.-S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abde8a · Cited by 69
“24,74 Even though fixed decoders exhibited a significant performance decline (as anticipated), their decoding performance was still moderately good in most (except a few) sessions.”
BackgroundMethodResultInfluentialReal-time estimation and biofeedback of single-neuron firing rates using local field potentials
Hall, T. M., Nazarpour, K., & Jackson, A. (2014) · Nature Communications · doi:10.1038/ncomms6462 · Cited by 61
“…the summation of postsynaptic potentials over at least a few hundred micrometres from the recording site 10-15 , LFPs may be less sensitive to micro-movements and encapsulation of electrodes 16,17 and kinematic information can be retrieved even from electrodes without clear spike activity 18,19 .”
Recording and decoding for neural prostheses
Warren, D. J., Kellis, S., Nieveen, J. G., Wendelken, S. M., Dantas, H., Davis, T. S., Hutchinson, D. T., Normann, R. A., Clark, G. A., & Mathews, V. J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2507180 · Cited by 52
Metadata
- Authors
- Wang, D., Zhang, Q., Li, Y., Wang, Y., Zhu, J., Zhang, S., & Zheng, X.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-05-08
- Volume
- 11
- Issue
- 3
- Pages
- 036009
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1972122710
- Cited by
- 58
- References
- 15
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term decoding stability of local field potentials from silicon arrays in primate motor cortex during a 2D center out task. https://app.cochat.ai/papers/10.1088/1741-2560/11/3/036009
- The paper
- Wang, D., Zhang, Q., Li, Y., Wang, Y., Zhu, J., Zhang, S., & Zheng, X. (2014). Long-term decoding stability of local field potentials from silicon arrays in primate motor cortex during a 2D center out task. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/11/3/036009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.