The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Comparative analyses of volatile organic compounds (VOCs) from patients, tumors and transformed cell lines for the validation of lung cancer-derived breath markers
Open accessAbstract
Breath analysis for the purpose of non-invasive diagnosis of lung cancer has yielded numerous candidate compounds with still questionable clinical relevance. To arrive at suitable volatile organic compounds our approach combined the analysis of different sources: isolated tumor samples compared to healthy lung tissues, and exhaled breath from lung cancer patients and healthy controls. Candidate compounds were further compared to substances previously identified in the comparison of transformed and normal lung epithelial cell lines. For human studies, a breath sampling device was developed enabling automated and CO2-controlled collection of the end-tidal air. All samples were first preconcentrated on multibed sorption tubes and analyzed with gas chromatography mass spectrometry (GC-MS). Significantly (p < 0.05) higher concentrations in all three types of cancer samples studied were observed for ethanol and n-octane. Additional metabolites (inter alia 2-methylpentane, n-hexane) significantly released by lung cancer cells were observed at higher levels in cancer lung tissues and breath samples (compared to respective healthy controls) with statistical significance (p < 0.05) only in breath samples. The results obtained confirmed the cancer-related origin of volatile metabolites, e.g. ethanol and octane that were both detected at significantly (p < 0.05) elevated concentrations in all three kinds of cancer samples studied. This work is an important step towards identification of volatile breath markers of lung cancer through the demonstration of cancer-related origin of certain volatile metabolites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
The National Lung Screening Trial Research Team (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102873 · Cited by 11,064
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Self-citationVolatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953 · cited 3×
“Similarly, 4-methyloctane has been reported to be cancerassociated by Phillips et al [25] and Hakim et al [34].”
BackgroundSelf-citationSmith-Bindman, R., Miglioretti, D. L., Johnson, E., Lee, C., Feigelson, H. S., Flynn, M., Greenlee, R. T., Kruger, R. L., Hornbrook, M. C., Roblin, D., et al. (2012) · JAMA · doi:10.1001/jama.2012.5960 · Cited by 898
Cited by
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationRecent advances in biosensor for detection of lung cancer biomarkers
Yang, G., Xiao, Z., Tang, C., Deng, Y., Huang, H., & He, Z. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111416 · Cited by 330
Hybrid Volatolomics and Disease Detection
Broza, Y. Y., Mochalski, P., Ruzsanyi, V., Amann, A., & Haick, H. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201500153 · Cited by 290
Self-citationExhaled breath analysis: a review of ‘breath-taking’ methods for off-line analysis
Lawal, O., Ahmed, W. M., Nijsen, T. M. E., Goodacre, R., & Fowler, S. J. (2017) · Metabolomics · doi:10.1007/s11306-017-1241-8 · Cited by 288
Drabińska, N., Flynn, C., Ratcliffe, N., Belluomo, I., Myridakis, A., Gould, O., Fois, M., Smart, A., Devine, T., & Costello, B. D. L. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/abf1d0 · Cited by 288
Metadata
- Authors
- Filipiak, W., Filipiak, A., Sponring, A., Schmid, T., Zelger, B., Ager, C., Klodzinska, E., Denz, H., Pizzini, A., Lucciarini, P., Jamnig, H., Troppmair, J., & Amann, A.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2014-05-27
- Volume
- 8
- Issue
- 2
- Pages
- 027111
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W2153001247
- Cited by
- 173
- References
- 4
- FWCI
- 6.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative analyses of volatile organic compounds (VOCs) from patients, tumors and transformed cell lines for the validation of lung cancer-derived breath markers. https://app.cochat.ai/papers/10.1088/1752-7155/8/2/027111
- The paper
- Filipiak, W., Filipiak, A., Sponring, A., Schmid, T., Zelger, B., Ager, C., Klodzinska, E., Denz, H., Pizzini, A., Lucciarini, P., Jamnig, H., Troppmair, J., & Amann, A. (2014). Comparative analyses of volatile organic compounds (VOCs) from patients, tumors and transformed cell lines for the validation of lung cancer-derived breath markers. Journal of Breath Research. https://doi.org/10.1088/1752-7155/8/2/027111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.