Evaluation of poly(3,4-ethylenedioxythiophene)/carbon nanotube neural electrode coatings for stimulation in the dorsal root ganglion
Open accessThe DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The dorsal root ganglion is an attractive target for implanting neural electrode arrays that restore sensory function or provide therapy via stimulation. However, penetrating microelectrodes designed for these applications are small and deliver low currents. For long-term performance of microstimulation devices, novel coating materials are needed in part to decrease impedance values at the electrode-tissue interface and to increase charge storage capacity. APPROACH: Conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT) and multi-wall carbon nanotubes (CNTs) were coated on the electrode surface and doped with the anti-inflammatory drug, dexamethasone. Electrode characteristics and the tissue reaction around neural electrodes as a result of stimulation, coating and drug release were characterized. Hematoxylin and eosin staining along with antibodies recognizing Iba1 (microglia/macrophages), NF200 (neuronal axons), NeuN (neurons), vimentin (fibroblasts), caspase-3 (cell death) and L1 (neural cell adhesion molecule) were used. Quantitative image analyses were performed using MATLAB. MAIN RESULTS: Our results indicate that coated microelectrodes have lower in vitro and in vivo impedance values. Significantly less neuronal death/damage was observed with coated electrodes as compared to non-coated controls. The inflammatory response with the PEDOT/CNT-coated electrodes was also reduced. SIGNIFICANCE: This study is the first to report on the utility of these coatings in stimulation applications. Our results indicate PEDOT/CNT coatings may be valuable additions to implantable electrodes used as therapeutic modalities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“PEDOT/CNT films were assessed for their utility in modifying a PNS interface, and it was found that coated electrodes exhibited improved neuronal responses at the interface and decreased expression of neuronal apoptosis markers following implantation into the DRG of rats.43”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [43]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Poly(3,4-ethylenedioxythiophene) and Its Derivatives: Past, Present, and Future
Groenendaal, L., Jonas, F., Freitag, D., Pielartzik, H., & Reynolds, J. R. (2000) · Advanced Materials · doi:10.1002/(sici)1521-4095(200004)12:7<481::aid-adma481>3.0.co;2-c · Cited by 3,420 · cited 1×
“Furthermore, PEDOT has improved electrochemical, mechanical and thermal stability necessary for use in chronic implants [31].”
BackgroundNeural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 2×
“Among the various conducting polymers, poly(3,4-ethylenedioxythiophene) (PEDOT) has been shown to be an excellent material for neural stimulation as a result of its superior impedance and charge injection capacity when compared to thin film platinum (Pt) electrodes [7, 28, 29].”
BackgroundElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“stabilize the electrode potential from any ‘ratcheting’ effects [46].”
BackgroundApplications of Carbon Nanotubes in Drug Delivery
Kaur, J., Gill, G. S., & Jeet, K. (2019) · Characterization and Biology of Nanomaterials for Drug Delivery · doi:10.1016/b978-0-12-814031-4.00005-2 · Cited by 2,019
(2006) · Advanced Materials · doi:10.1002/(issn)1521-4095 · Cited by 1,662
Stimuli-Responsive Polymer Nanocomposites Inspired by the Sea Cucumber Dermis
Capadona, J. R., Shanmuganathan, K., Tyler, D. J., Rowan, S. J., & Weder, C. (2008) · Science · doi:10.1126/science.1153307 · Cited by 962 · cited 1×
“To address the mechanical mismatch between current electrode materials and brain tissue, a number of groups are also investigating soft materials with mechanical properties similar to those of central nervous system (CNS) or peripheral nervous system (PNS) tissue [18-23].”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · cited 1×
“Biocompatibility issues resulting in immune and inflammatory reactions prevent functional integration with the surrounding neural tissue and cause chronic neuronal degeneration [8, 9].”
BackgroundConducting‐Polymer Nanotubes for Controlled Drug Release
Abidian, M. R., Kim, D. ‐., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200501726 · Cited by 869 · cited 2×
“Additionally, anti-inflammatory agents like dexamethasone have been successfully incorporated and electrically released from conducting polymers to inhibit the inflammatory tissue response [27, 32].”
BackgroundFunctionalization density dependence of single-walled carbon nanotubes cytotoxicity in vitro
Sayes, C. M., Liang, F., Hudson, J. L., Mendez, J., Guo, W., Beach, J. M., Moore, V. C., Doyle, C. D., West, J. L., Billups, W. E., et al. (2006) · Toxicology Letters · doi:10.1016/j.toxlet.2005.08.011 · Cited by 856 · cited 1×
“In addition, CNTs have low toxicity, no immunogenicity [36-38] and can act as a nanoreservoir for targeted drug delivery using controlled drug release [39, 40].”
BackgroundBhirde, A. A., Patel, V., Gavard, J., Zhang, G., Sousa, A. A., Masedunskas, A., Leapman, R. D., Weigert, R., Gutkind, J. S., & Rusling, J. F. (2009) · ACS Nano · doi:10.1021/nn800551s · Cited by 853 · cited 1×
“In addition, CNTs have low toxicity, no immunogenicity [36-38] and can act as a nanoreservoir for targeted drug delivery using controlled drug release [39, 40].”
Background
Research works printed but not linked: 2
- 10.1002/(issn)1521-4095 · DOI · Paper page
- 10.1111/ner.2004.7.issue-2 · doi:10.1111/ner.2004.7.issue-2
Cited by
Items 101–124 of 124
Ghosh, S., Sahaluddin, M., Abdulhafez, M., Pwint, M. Y., Cui, X. T., & Bedewy, M. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202502433 · Cited by 7
Shu, Y., Yang, S., Li, P., Gou, S., Cheng, Y., Jia, Q., & Du, Z. J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1476447 · Cited by 4
Self-citationCentral nervous system responses to biomaterials
Tsintou, M., Wróbel, P. P., & Dalamagkas, K. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102967-1.00023-2 · Cited by 4
Folch, A. (2016) · CRC Press eBooks · doi:10.1201/b12263-12 · Cited by 4
State-of-the-Art Technology on Highly Miniaturized Free-Floating Neural Implants
Khalifa, A., & Etienne‐Cummings, R. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_114 · Cited by 3
Bioelectronics and Neural Interfaces
Tong, W., Robles, U. A. A., & Gelmi, A. A. (2021) · Royal Society of Chemistry eBooks · doi:10.1039/9781788019828-00180 · Cited by 2
He, Z., Ma, J., Liu, Y., & Du, Z. J. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27156752 · Cited by 2
“…local tissue damage in dorsal root ganglion stimulation model, while MXene/poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) microscale fiber electrode embodies the latest trend of combining two-dimensional conductive materials with flexible microelectrode structures [65,66].”
Self-citationSkeletal muscle tissue engineering
Schäfer, B., Cai, A., Ruhl, T., & Beier, J. P. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820508-2.00015-5 · Cited by 1
State-of-the-Art Technology on Highly Miniaturized Free-Floating Neural Implants
Khalifa, A., & Etienne‐Cummings, R. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_114-1 · Cited by 1
Carbon-based nanomaterials for nervous tissue engineering
Tite, T., Balescu, L. M., Popa, A.-C., & Stan, G. E. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-90554-1.00007-0 · Cited by 1
Electrically Conductive DNA-Inspired Coating for Intracortical Neural MicroelectrodesPreprint
Sands, I., Ersöz, A., Zhang, W., Zhou, L., Linthicum, W., Santaniello, S., Huey, B. D., Han, M., & Chen, Y. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.06.19.545632 · Cited by 1
“In particular, while some coatings offer reduced impedances which reflect neural recording property, most have not demonstrated improvements in neural stimulation with relevant charge injection capacity [14-21].”
BackgroundShoffstall, A. J., & Capadona, J. R. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816137-1.00073-8
Biomedical applications of carbon nanotubes
Mancino, D., & Alegret, N. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821996-6.00003-8
Li, W., & Qiu, Z. (2019) · MDPI eBooks · doi:10.3390/books978-3-03921-661-1
Nanomaterials for Spinal Cord Injury Recovery
Amezcua, R., Vimbela, G. V., & Stout, D. (2017) · Spine Research · doi:10.21767/2471-8173.10003
Muscle tissue repair and regeneration: role of biocomposites
Dasgupta, S., Singh, Y. P., & Ray, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-19074-2.00011-3
Micro- and Nanotechnologies in Nerve Repair
Shevy, D. S., Emadzadeh, M., Kateb, B., Ravanpay, A. C., & Kliot, M. (2024) · Springer eBooks · doi:10.1007/978-3-030-80662-0_35
Biomaterials for Neuroregeneration: Mechanisms and Therapeutic Applications
Yadav, D., Singh, A. K., & Sharma, P. K. (2025) · Springer eBooks · doi:10.1007/978-981-97-9959-6_5 · Cited by 1
Modern Concepts of Endoneurial Fibroblasts
Petrova, E. S., & Kolos, E. A. (2025) · Journal of Evolutionary Biochemistry and Physiology · doi:10.1134/s0022093025030020
Understanding the Effects of Conductive Polymer Electrode Coating on Recorded Neural Signals
Sridhar, K., Evers, J., Trotier, A., Biggs, M. J. P., & Lowery, M. M. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202503893
“Impedance data were recorded from both standard chronically implanted PtIr recording electrodes and PtIr electrodes in which electrode impedance was reduced by the application of a current which reduced biofouling due to protein absorption [26].”
InfluentialBiocapteurs implantables pour un monitorage intracérébral minimalement invasif
Chatard, C. (2018) · theses.fr (ABES) · doi:10.70675/1880b7a0z30d6z4a12za2b9za72ac2b0053b
Carbon Fiber Microelectrode Arrays for Neuroprosthetic and Neuroscience Applications.
Patel, P. R. (2015) · Deep Blue (University of Michigan) · Cited by 4
Vreeland, R. F. (2015) · UA Campus Repository (The University of Arizona)
Metadata
- Authors
- Kolarcik, C. L., Catt, K., Rost, E., Albrecht, I. N., Bourbeau, D., Du, Z., Kozai, T. D. Y., Luo, X., Weber, D. J., & Tracy Cui, X.
- Affiliations
- University of Pittsburgh (US)
- Qingdao University of Science and Technology (CN)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-12-08
- Volume
- 12
- Issue
- 1
- Pages
- 016008
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC4433052
- OpenAlex
- W2045925821
- Semantic Scholar
- 57158d0a2f630484004ccda825e83c570fb81a52
- Cited by
- 126
- References
- 78
- Citations by year
- 2026: 1 · 2025: 8 · 2024: 8 · 2023: 14 · 2022: 11 · 2021: 13 · 2020: 9 · 2019: 16 · 2018: 12 · 2017: 14 · 2016: 6 · 2015: 10 · 2014: 2
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Agriculture
- National Institutes of Health (TL1TR000145, 4r01ns072342-05, UL1TR000005)
- National Institute of Neurological Disorders and Stroke (R01-NS072342, R01NS062019)
- National Center for Advancing Translational Sciences
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- PEDOT, carbon nanotubes, dorsal root ganglia, microelectrode stimulation, electrode impedance, charge storage capacity, neuroinflammation, microglia/macrophages, neuronal cell death
- MeSH terms
- Animals, Anti-Inflammatory Agents, Dexamethasone, Drug Implants, Electric Conductivity, Equipment Design, Female, Ganglia, Spinal, Materials Testing, Microelectrodes, Polymers, Sensitivity and Specificity, Reproducibility of Results, Rats, Sprague-Dawley, Bridged Bicyclo Compounds, Heterocyclic, Equipment Failure Analysis, Coated Materials, Biocompatible, Nanotubes, Carbon, Rats, Nanocapsules, Spinal Cord Stimulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.