Filter bank canonical correlation analysis for implementing a high-speed SSVEP-based brain–computer interface
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Recently, canonical correlation analysis (CCA) has been widely used in steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs) due to its high efficiency, robustness, and simple implementation. However, a method with which to make use of harmonic SSVEP components to enhance the CCA-based frequency detection has not been well established. APPROACH: This study proposed a filter bank canonical correlation analysis (FBCCA) method to incorporate fundamental and harmonic frequency components to improve the detection of SSVEPs. A 40-target BCI speller based on frequency coding (frequency range: 8-15.8 Hz, frequency interval: 0.2 Hz) was used for performance evaluation. To optimize the filter bank design, three methods (M1: sub-bands with equally spaced bandwidths; M2: sub-bands corresponding to individual harmonic frequency bands; M3: sub-bands covering multiple harmonic frequency bands) were proposed for comparison. Classification accuracy and information transfer rate (ITR) of the three FBCCA methods and the standard CCA method were estimated using an offline dataset from 12 subjects. Furthermore, an online BCI speller adopting the optimal FBCCA method was tested with a group of 10 subjects. MAIN RESULTS: The FBCCA methods significantly outperformed the standard CCA method. The method M3 achieved the highest classification performance. At a spelling rate of ∼33.3 characters/min, the online BCI speller obtained an average ITR of 151.18 ± 20.34 bits min(-1). SIGNIFICANCE: By incorporating the fundamental and harmonic SSVEP components in target identification, the proposed FBCCA method significantly improves the performance of the SSVEP-based BCI, and thereby facilitates its practical applications such as high-speed spelling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“To evaluate the performance of the proposed method, classi fi cation accuracy and ITR (Wolpaw et al 2002) were calculated for the online and of fl ine experiments separately.”
MethodWavelets and filter banks: theory and design
Vetterli, M., & Herley, C. (1992) · IEEE Transactions on Signal Processing · doi:10.1109/78.157221 · Cited by 1,690
Time-Frequency Signal Analysis and Processing
(2016) · doi:10.1016/c2012-0-00024-5 · Cited by 1,340
Human Brain Electrophysiology: Evoked Potentials and Evoked Magnetic Fields in Science and Medicine
Regan, D. M. (1989) · Medical Entomology and Zoology · Cited by 1,300
Filter Bank Common Spatial Pattern Algorithm on BCI Competition IV Datasets 2a and 2b
Ang, K. K., Chin, Z. Y., Wang, C., Guan, C., & Zhang, H. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00039 · Cited by 1,264 · cited 1×
“For example, a fi lter bank common spatial pattern (FBCSP) method was proposed to extract EEG power features in mu-and beta-frequency bands and signi fi cantly improved the discrimination of different motor imagery states (Ang et al 2012).”
MethodHerrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080 · cited 3×
“More speci fi cally, SSVEPs consist of brain responses at frequencies identical, harmonic, and sub-har-monic to the stimulation frequency (Herrmann 2001).”
BackgroundMethodInfluentialSteady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066 · cited 1×
“The steady-state visual evoked potential (SSVEP)-based brain – computer interface (BCI) has attracted more and more attention in the fi eld of BCI due to its advantages such as high information transfer rate (ITR) and little user training (Wang et al 2008, Vialatte et al 2010).”
BackgroundFrequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
Self-citationDesign and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818
Self-citation
Cited by
EEG Conformer: Convolutional Transformer for EEG Decoding and Visualization
Song, Y., Zheng, Q., Liu, B., & Gao, X. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3230250 · Cited by 1,095
Self-citationHigh-speed spelling with a noninvasive brain–computer interface
Chen, X., Wang, Y., Nakanishi, M., Gao, X., Jung, T.-P., & Gao, S. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1508080112 · Cited by 969
Self-citationEnhancing Detection of SSVEPs for a High-Speed Brain Speller Using Task-Related Component Analysis
Nakanishi, M., Wang, Y., Chen, X., Wang, Y.-T., Gao, X., & Jung, T.-P. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2694818 · Cited by 813
Self-citationRashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
A Benchmark Dataset for SSVEP-Based Brain–Computer Interfaces
Wang, Y., Chen, X., Gao, X., & Gao, S. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2627556 · Cited by 501
Self-citationXu, M., Xiao, X., Wang, Y., Qi, H., Jung, T.-P., & Ming, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2799661 · Cited by 227
Self-citationLiu, B., Chen, X., Shi, N., Wang, Y., Gao, S., & Gao, X. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3114340 · Cited by 215
Self-citationBETA: A Large Benchmark Database Toward SSVEP-BCI Application
Liu, B., Huang, X., Wang, Y., Chen, X., & Gao, X. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00627 · Cited by 209
“…(2007)), canonical correlation analysis (CCA, Bin et al. (2009)), multivariate synchronization index (MSI, Zhang et al. (2014)), filter bank canonical correlation analysis (FBCCA, Chen et al. (2015a)) and canonical variates with autoregressive spectral analysis (CVARS, Abu-Alqumsan and Peer (2016)).”
InfluentialSelf-citationReview of semi-dry electrodes for EEG recording
Li, G.-L., Wu, J.-T., Xia, Y.-H., He, Q.-G., & Jin, H.-G. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abbd50 · Cited by 178
“Despite the incomplete spectral characterization for alpha rhythm and SSVEP, it is sufficient for some BCI applications [137, 138].”
BackgroundComparing user-dependent and user-independent training of CNN for SSVEP BCI
Ravi, A., Beni, N. H., Manuel, J., & Jiang, N. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab6a67 · Cited by 165
“Most widely used UD methods include: Combination method-CCA [12], Individual Template CCA (IT-CCA) [13] and more recently proposed Task Related Components Analysis (TRCA) [14]; UI methods include: Filter-Bank CCA (FBCCA) [15], Combined-tCCA and Adaptive Combined CCA (A3C) [16].”
MethodXu, M., Han, J., Wang, Y., Jung, T.-P., & Ming, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2975614 · Cited by 165
“proposed a joint frequency-phase modulation method (JFPM) that encoded 40 instructions for SSVEP-BCI [21], [24].”
BackgroundMethodInfluentialSelf-citationTo train or not to train? A survey on training of feature extraction methods for SSVEP-based BCIs
Zerafa, R., Camilleri, T., Falzon, O., & Camilleri, K. P. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaca6e · Cited by 160
“Multiple Model-based MEC (2007) [13] p-CCA (2011) [26] FBCCA (2015) [27]”
Combination of high-frequency SSVEP-based BCI and computer vision for controlling a robotic arm
Chen, X., Zhao, B., Wang, Y., & Gao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf594 · Cited by 159
Self-citationZhang, B., Xu, M., Zhang, Y., Ye, S., & Chen, Y. (2024) · Bioengineering · doi:10.3390/bioengineering11040347 · Cited by 4
“This represents a novel paradigm in BCI that emerged after steady state visual evoked potential (SSVEP) and motor imagery [4,5].”
Background
Metadata
- Authors
- Chen, X., Wang, Y., Gao, S., Jung, T.-P., & Gao, X.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-06-02
- Volume
- 12
- Issue
- 4
- Pages
- 046008
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2143183535
- Cited by
- 805
- References
- 43
- FWCI
- 14.57
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.