Isolating gait-related movement artifacts in electroencephalography during human walking
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: High-density electroencephelography (EEG) can provide an insight into human brain function during real-world activities with walking. Some recent studies have used EEG to characterize brain activity during walking, but the relative contributions of movement artifact and electrocortical activity have been difficult to quantify. We aimed to characterize movement artifact recorded by EEG electrodes at a range of walking speeds and to test the efficacy of artifact removal methods. We also quantified the similarity between movement artifact recorded by EEG electrodes and a head-mounted accelerometer. APPROACH: We used a novel experimental method to isolate and record movement artifact with EEG electrodes during walking. We blocked electrophysiological signals using a nonconductive layer (silicone swim cap) and simulated an electrically conductive scalp on top of the swim cap using a wig coated with conductive gel. We recorded motion artifact EEG data from nine young human subjects walking on a treadmill at speeds from 0.4 to 1.6 m s(-1). We then tested artifact removal methods including moving average and wavelet-based techniques. MAIN RESULTS: Movement artifact recorded with EEG electrodes varied considerably, across speed, subject, and electrode location. The movement artifact measured with EEG electrodes did not correlate well with head acceleration. All of the tested artifact removal methods attenuated low-frequency noise but did not completely remove movement artifact. The spectral power fluctuations in the movement artifact data resembled data from some previously published studies of EEG during walking. SIGNIFICANCE: Our results suggest that EEG data recorded during walking likely contains substantial movement artifact that: cannot be explained by head accelerations; varies across speed, subject, and channel; and cannot be removed using traditional signal processing methods. Future studies should focus on more sophisticated methods for removal of EEG movement artifact to advance the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 4×
“We used bootstrapping methods available in EEGLAB (Delorme and Makeig 2004) to determine regions of significant difference from baseline (p 0.05).”
MethodInfluentialOrthonormal bases of compactly supported wavelets
Daubechies, I. (1988) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.3160410705 · Cited by 8,190 · cited 2×
“We chose Daubechies wavelets based on their previous usage in EEG studies to identify low frequency spectral fluctuations (Daubechies 1988, Adeli et al 2003 ).”
MethodRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618 · cited 1×
“EEG offers better temporal resolution than fNIRS (Villringer and Chance 1997, Irani et al 2007), because EEG measures fast electrical potential changes rather than a slow metabolic signal.”
BackgroundMining event-related brain dynamics
Makeig, S., Debener, S., Onton, J., & Delorme, A. (2004) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2004.03.008 · Cited by 1,493 · cited 3×
“EEG has inherently good (millisecond) temporal resolution, and inverse source modeling techniques can provide spatial localization in the range of 1 cm (Makeig et al 1996, 2004a, 2004b, Mullen et al 2011).”
BackgroundMethodJung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
Analysis of EEG records in an epileptic patient using wavelet transform
Adeli, H., Zhou, Z., & Dadmehr, N. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00340-0 · Cited by 1,154 · cited 2×
“We chose Daubechies wavelets based on their previous usage in EEG studies to identify low frequency spectral fluctuations (Daubechies 1988, Adeli et al 2003 ).”
MethodAuditory event-related dynamics of the EEG spectrum and effects of exposure to tones
Makeig, S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90110-h · Cited by 844 · cited 1×
“We then averaged these ERSPs across all subjects (Makeig 1993, Makeig et al 2004a).”
MethodCortical Mapping of Gait in Humans: A Near-Infrared Spectroscopic Topography Study
Miyai, I., Tanabe, H. C., Sase, I., Eda, H., Oda, I., Konishi, I., Tsunazawa, Y., Suzuki, T., Yanagida, T., & Kubota, K. (2001) · NeuroImage · doi:10.1006/nimg.2001.0905 · Cited by 788 · cited 3×
“ASR is a more complex, sophisticated method for movement-related artifact removal, but is beyond the scope of this paper.”
MethodSuzuki, M., Miyai, I., Ono, T., Oda, I., Konishi, I., Kochiyama, T., & Kubota, K. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.002 · Cited by 541 · cited 1×
“Functional near-infrared spectroscopy (fNIRS) has been used to study walking previously (Miyai et al 2001, Suzuki et al 2004, Harada et al 2009), but it relies on a hemodynamic response, which has poorer temporal resolution.”
MethodEffects of obesity and sex on the energetic cost and preferred speed of walking
Browning, R. C., Baker, E. A., Herron, J. A., & Kram, R. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00767.2005 · Cited by 488
Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00105.2010 · Cited by 481 · cited 6×
“We used 10 strides and a 10 Hz low-pass filter cutoff, based on (Gwin et al 2010).”
BackgroundMethodInfluentialSelf-citationElectrocortical activity is coupled to gait cycle phase during treadmill walking
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.066 · Cited by 479 · cited 5×
“Several past studies have found spectral power increases during double support and spectral power decreases during single support at alpha and beta frequencies of scalp EEG at normal walking speeds, 0.78–1.25 m s−1 (Gwin et al 2011, Cheron et al 2012, Severens et al 2012).”
BackgroundMethodInfluentialSelf-citationIrani, F., Platek, S. M., Bunce, S., Ruocco, A. C., & Chute, D. (2007) · The Clinical Neuropsychologist · doi:10.1080/13854040600910018 · Cited by 451 · cited 1×
“EEG offers better temporal resolution than fNIRS (Villringer and Chance 1997, Irani et al 2007), because EEG measures fast electrical potential changes rather than a slow metabolic signal.”
BackgroundReal-time modeling and 3D visualization of source dynamics and connectivity using wearable EEG
Mullen, T., Kothe, C., Chi, Y. M., Ojeda, A., Kerth, T., Makeig, S., Cauwenberghs, G., & Jung, T.-P. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609968 · Cited by 390 · cited 3×
“ASR is a more complex, sophisticated method for movement-related artifact removal, but is beyond the scope of this paper.”
MethodElectroencephalographic Brain Dynamics Following Manually Responded Visual Targets
Makeig, S., Delorme, A., Westerfield, M., Jung, T.-P., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2004) · PLoS Biology · doi:10.1371/journal.pbio.0020176 · Cited by 357
Wagner, J., Solis-Escalante, T., Grieshofer, P., Neuper, C., Müller-Putz, G., & Scherer, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.019 · Cited by 301 · cited 2×
“…also proved the feasibility of measuring scalp electrocortical signals during human walking, at speeds ranging from 0.42 to 1.9 m s−1, to provide insight into brain function (Gramann et al 2010, Cheron et al 2012, Lau et al 2012, Severens et al 2012, Wagner et al 2012, Seeber et al 2014, 2015).”
BackgroundInfluentialSweeney, K. T., McLoone, S. F., & Ward, T. E. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2225427 · Cited by 300 · cited 1×
“Blind source separation techniques, such as independent component analysis and canonical correlation analysis (Sweeney et al 2013), have been successful at separating eye and muscular artifacts from EEG data (Jung et al 2000a, 2000b), but they may be less successful with movement artifact due to…”
MethodGait capacity affects cortical activation patterns related to speed control in the elderly
Harada, T., Miyai, I., Suzuki, M., & Kubota, K. (2009) · Experimental Brain Research · doi:10.1007/s00221-008-1643-y · Cited by 281 · cited 1×
“Functional near-infrared spectroscopy (fNIRS) has been used to study walking previously (Miyai et al 2001, Suzuki et al 2004, Harada et al 2009), but it relies on a hemodynamic response, which has poorer temporal resolution.”
MethodLoss of balance during balance beam walking elicits a multifocal theta band electrocortical response
Sipp, A. R., Gwin, J. T., Makeig, S., & Ferris, D. P. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00744.2012 · Cited by 232 · cited 3×
“Our laboratory has recorded electrocortical spectral fluctuations during treadmill walking in healthy, young adults (Gwin et al 2011, Sipp et al 2013).”
BackgroundMethodInfluentialSelf-citationVisual Evoked Responses During Standing and Walking
Gramann, K., Gwin, J. T., Bigdely-Shamlo, N., Ferris, D. P., & Makeig, S. (2010) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2010.00202 · Cited by 229
Self-citationEEG beta suppression and low gamma modulation are different elements of human upright walking
Seeber, M., Scherer, R., Wagner, J., Solis-Escalante, T., & Müller-Putz, G. R. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00485 · Cited by 219 · cited 1×
“…also proved the feasibility of measuring scalp electrocortical signals during human walking, at speeds ranging from 0.42 to 1.9 m s−1, to provide insight into brain function (Gramann et al 2010, Cheron et al 2012, Lau et al 2012, Severens et al 2012, Wagner et al 2012, Seeber et al 2014, 2015).”
BackgroundInfluentialSeeber, M., Scherer, R., Wagner, J., Solis-Escalante, T., & Müller-Putz, G. R. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.045 · Cited by 186 · cited 1×
“…also proved the feasibility of measuring scalp electrocortical signals during human walking, at speeds ranging from 0.42 to 1.9 m s−1, to provide insight into brain function (Gramann et al 2010, Cheron et al 2012, Lau et al 2012, Severens et al 2012, Wagner et al 2012, Seeber et al 2014, 2015).”
BackgroundInfluentialCastermans, T., Duvinage, M., Cheron, G. A., & Dutoit, T. (2014) · Neuroscience Letters · doi:10.1016/j.neulet.2013.12.059 · Cited by 173
Cheron, G., Duvinage, M., De Saedeleer, C., Castermans, T., Bengoetxea, A., Petieau, M., Seetharaman, K., Hoellinger, T., Dan, B., Dutoit, T., et al. (2012) · Neural Plasticity · doi:10.1155/2012/375148 · Cited by 113 · cited 2×
“…also proved the feasibility of measuring scalp electrocortical signals during human walking, at speeds ranging from 0.42 to 1.9 m s−1, to provide insight into brain function (Gramann et al 2010, Cheron et al 2012, Lau et al 2012, Severens et al 2012, Wagner et al 2012, Seeber et al 2014, 2015).”
BackgroundInfluentialLau, T., Gwin, J. T., McDowell, K., & Ferris, D. P. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-47 · Cited by 111
Self-citationChowdhury, M. E. H., Mullinger, K. J., Glover, P. M., & Bowtell, R. W. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.08.039 · Cited by 102 · cited 2×
“They used a reference layer with similar conductivity to the human head to allow subtraction of movement-related and MRI-related artifacts during simultaneous EEG–fMRI recordings (Chowdhury et al 2014).”
MethodResultFeasibility of measuring event Related Desynchronization with electroencephalography during walking
Severens, M., Nienhuis, B., Desain, P., & Duysens, J. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346537 · Cited by 100 · cited 2×
“…also proved the feasibility of measuring scalp electrocortical signals during human walking, at speeds ranging from 0.42 to 1.9 m s−1, to provide insight into brain function (Gramann et al 2010, Cheron et al 2012, Lau et al 2012, Severens et al 2012, Wagner et al 2012, Seeber et al 2014, 2015).”
BackgroundInfluentialKline, J. E., Poggensee, K. L., & Ferris, D. P. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00288 · Cited by 79 · cited 3×
“Heel-strikes 213 corresponded to the times of the troughs of the calcaneus marker vertical position and toe-offs 214 corresponded to the times of the peaks of the calcaneus marker velocity in the vertical direction 215 (Kline et al., 2014).”
BackgroundSelf-citationAutomatic detection of EEG artefacts arising from head movements using EEG and gyroscope signals
O’Regan, S., Faul, S., & Marnane, W. P. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.08.017 · Cited by 76
Multimodal detection of head-movement artefacts in EEG
O’Regan, S., & Marnane, W. P. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.04.017 · Cited by 49
Modeling cortical source dynamics and interactions during seizure
Mullen, T. R., Acar, Z. A., Worrell, G. A., & Makeig, S. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090332 · Cited by 33
Intelligent artifact classification for ambulatory physiological signals
Sweeney, K. T., Leamy, D. J., Ward, T. E., & McLoone, S. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627285 · Cited by 16 · cited 1×
“Past studies have used accelerometers to measure movement artifacts in non-ambulatory tasks such as nodding and shaking of the head (Sweeney et al 2010, O’Regan and Marnane 2013, O’Regan et al 2013).”
Background
Cited by
Deep learning for electroencephalogram (EEG) classification tasks: a review
Craik, A., He, Y., & Contreras-Vidal, J. L. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0ab5 · Cited by 1,758
Wearable Sensing Technology Applications in Construction Safety and Health
Ahn, C. R., Lee, S., Sun, C., Jebelli, H., Yang, K., & Choi, B. (2019) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001708 · Cited by 290
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
Kwak, N.-S., Müller, K.-R., & Lee, S.-W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172578 · Cited by 272
Brain–machine interfaces for controlling lower-limb powered robotic systems
He, Y., Eguren, D., Azorín, J. M., Grossman, R. G., Luu, T. P., & Contreras-Vidal, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa8c0 · Cited by 224
“All EEG-based studies should benefit from artifact removal procedures as EEG data are known to contain artifacts (Kline et al 2015).”
Method
Metadata
- Authors
- Kline, J. E., Huang, H. J., Snyder, K. L., & Ferris, D. P.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-06-17
- Volume
- 12
- Issue
- 4
- Pages
- 046022
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2117263102
- Cited by
- 204
- References
- 34
- FWCI
- 12.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.