Isolating gait-related movement artifacts in electroencephalography during human walking
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: High-density electroencephelography (EEG) can provide an insight into human brain function during real-world activities with walking. Some recent studies have used EEG to characterize brain activity during walking, but the relative contributions of movement artifact and electrocortical activity have been difficult to quantify. We aimed to characterize movement artifact recorded by EEG electrodes at a range of walking speeds and to test the efficacy of artifact removal methods. We also quantified the similarity between movement artifact recorded by EEG electrodes and a head-mounted accelerometer. APPROACH: We used a novel experimental method to isolate and record movement artifact with EEG electrodes during walking. We blocked electrophysiological signals using a nonconductive layer (silicone swim cap) and simulated an electrically conductive scalp on top of the swim cap using a wig coated with conductive gel. We recorded motion artifact EEG data from nine young human subjects walking on a treadmill at speeds from 0.4 to 1.6 m s(-1). We then tested artifact removal methods including moving average and wavelet-based techniques. MAIN RESULTS: Movement artifact recorded with EEG electrodes varied considerably, across speed, subject, and electrode location. The movement artifact measured with EEG electrodes did not correlate well with head acceleration. All of the tested artifact removal methods attenuated low-frequency noise but did not completely remove movement artifact. The spectral power fluctuations in the movement artifact data resembled data from some previously published studies of EEG during walking. SIGNIFICANCE: Our results suggest that EEG data recorded during walking likely contains substantial movement artifact that: cannot be explained by head accelerations; varies across speed, subject, and channel; and cannot be removed using traditional signal processing methods. Future studies should focus on more sophisticated methods for removal of EEG movement artifact to advance the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 4×
“We used bootstrapping methods available in EEGLAB (Delorme and Makeig 2004) to determine regions of significant difference from baseline (p 0.05).”
MethodInfluentialOrthonormal bases of compactly supported wavelets
Daubechies, I. (1988) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.3160410705 · Cited by 8,190 · cited 2×
“We chose Daubechies wavelets based on their previous usage in EEG studies to identify low frequency spectral fluctuations (Daubechies 1988, Adeli et al 2003 ).”
MethodRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618 · cited 1×
“EEG offers better temporal resolution than fNIRS (Villringer and Chance 1997, Irani et al 2007), because EEG measures fast electrical potential changes rather than a slow metabolic signal.”
BackgroundMining event-related brain dynamics
Makeig, S., Debener, S., Onton, J., & Delorme, A. (2004) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2004.03.008 · Cited by 1,493 · cited 3×
“EEG has inherently good (millisecond) temporal resolution, and inverse source modeling techniques can provide spatial localization in the range of 1 cm (Makeig et al 1996, 2004a, 2004b, Mullen et al 2011).”
BackgroundMethodJung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
Analysis of EEG records in an epileptic patient using wavelet transform
Adeli, H., Zhou, Z., & Dadmehr, N. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00340-0 · Cited by 1,154 · cited 2×
“We chose Daubechies wavelets based on their previous usage in EEG studies to identify low frequency spectral fluctuations (Daubechies 1988, Adeli et al 2003 ).”
MethodAuditory event-related dynamics of the EEG spectrum and effects of exposure to tones
Makeig, S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90110-h · Cited by 844 · cited 1×
“We then averaged these ERSPs across all subjects (Makeig 1993, Makeig et al 2004a).”
MethodCortical Mapping of Gait in Humans: A Near-Infrared Spectroscopic Topography Study
Miyai, I., Tanabe, H. C., Sase, I., Eda, H., Oda, I., Konishi, I., Tsunazawa, Y., Suzuki, T., Yanagida, T., & Kubota, K. (2001) · NeuroImage · doi:10.1006/nimg.2001.0905 · Cited by 788 · cited 3×
“ASR is a more complex, sophisticated method for movement-related artifact removal, but is beyond the scope of this paper.”
Method
Cited by
Deep learning for electroencephalogram (EEG) classification tasks: a review
Craik, A., He, Y., & Contreras-Vidal, J. L. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0ab5 · Cited by 1,758
Wearable Sensing Technology Applications in Construction Safety and Health
Ahn, C. R., Lee, S., Sun, C., Jebelli, H., Yang, K., & Choi, B. (2019) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001708 · Cited by 290
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
Kwak, N.-S., Müller, K.-R., & Lee, S.-W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172578 · Cited by 272
Brain–machine interfaces for controlling lower-limb powered robotic systems
He, Y., Eguren, D., Azorín, J. M., Grossman, R. G., Luu, T. P., & Contreras-Vidal, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa8c0 · Cited by 224
“All EEG-based studies should benefit from artifact removal procedures as EEG data are known to contain artifacts (Kline et al 2015).”
MethodIdentification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018) · IEEE Access · doi:10.1109/access.2018.2842082 · Cited by 222
“Moreover, high-density EEG is another important and recent application for getting more insights into brain functionality during real-world activities [241].”
BackgroundConcealed, Unobtrusive Ear-Centered EEG Acquisition: cEEGrids for Transparent EEG
Bleichner, M. G., & Debener, S. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00163 · Cited by 215
“Motion of sensors, and motion of parts of the measurement system, however, may contribute strong interference and corrupt signals to an extend that the underlying brain activity cannot be recovered (Kline et al., 2015).”
BackgroundDistinct β Band Oscillatory Networks Subserving Motor and Cognitive Control during Gait Adaptation
Wagner, J., Makeig, S., Gola, M., Neuper, C., & Müller-Putz, G. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.3543-15.2016 · Cited by 193
“Two recent studies (Castermans et al., 2014; Kline et al., 2015) investigated movementrelated artifacts in the EEG during upright walking and found contamination of the EEG data at frequencies from 1 to 150 Hz.”
BackgroundMethodBrain Oscillations in Sport: Toward EEG Biomarkers of Performance
Cheron, G., Petit, G., Cheron, J., Leroy, A., Cebolla, A., Cevallos, C., Petieau, M., Hoellinger, T., Zarka, D., Clarinval, A.-M., et al. (2016) · Frontiers in Psychology · doi:10.3389/fpsyg.2016.00246 · Cited by 192
“…significance of the different oscillatory signals recorded from the scalp, the absence of standardized methodologies for sport domain, and the presence of different artifacts due to sport movement itself (Thompson et al., 2008; Reinecke et al., 2011; Castermans et al., 2014; Kline et al., 2015).”
BackgroundArtoni, F., Fanciullacci, C., Bertolucci, F., Panarese, A., Makeig, S., Micera, S., & Chisari, C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.013 · Cited by 183
“In this work we adopted several methods to minimize the influence on the results of artifacts in phase with the fundamental stepping frequency, which can mimic time-locked brain activation (Castermans et al., 2014; Kline et al., 2015).”
BackgroundMethodInfluentialStuart, S., Vitorio, R., Morris, R., Martini, D. N., Fino, P. C., & Mancini, M. (2018) · Maturitas · doi:10.1016/j.maturitas.2018.04.011 · Cited by 182
fNIRS response during walking — Artefact or cortical activity? A systematic review
Vitorio, R., Stuart, S., Rochester, L., Alcock, L., & Pantall, A. (2017) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2017.10.002 · Cited by 177
“A recent EEG study demonstrated that motion artefact increases with walking speed and channels are differentially affected (Kline et al., 2015).”
Freezing of gait: understanding the complexity of an enigmatic phenomenon
Weiss, D., Schoellmann, A., Fox, M. D., Bohnen, N. I., Factor, S. A., Nieuwboer, A., Hallett, M., & Lewis, S. J. G. (2020) · Brain · doi:10.1093/brain/awz314 · Cited by 176
“One important methodological issue to resolve in these studies is to gain reassurance that the observed spectral modulations do not simply reflect mechanical gait-related perturbations (Kline et al., 2015).”
BackgroundNeuroimaging of Human Balance Control: A Systematic Review
Wittenberg, E., Thompson, J., Nam, C. S., & Franz, J. R. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00170 · Cited by 171
“Like Castermans et al. (2014) and Kline et al. (2015) collected accelerometer data, however, there was poor correlation between the EEG and accelerometer signals.”
BackgroundMethodInfluentialShin, J. H., Kwon, J., Kim, J. U., Ryu, H., Ok, J., Joon Kwon, S., Park, H., & Kim, T.-I. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00164-w · Cited by 123
“The main problem with un fi xed and dangling connectors is that they generate indirect noise through random swinging motions across different frequency bands of vibration 45 – 47 .”
Background
Metadata
- Authors
- Kline, J. E., Huang, H. J., Snyder, K. L., & Ferris, D. P.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-06-17
- Volume
- 12
- Issue
- 4
- Pages
- 046022
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2117263102
- Cited by
- 204
- References
- 34
- FWCI
- 12.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.