Biomechanical analysis of silicon microelectrode-induced strain in the brain
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The ability to successfully interface the brain to external electrical systems is important both for fundamental understanding of our nervous system and for the development of neuroprosthetics. Silicon microelectrode arrays offer great promise in realizing this potential. However, when they are implanted into the brain, recording sensitivity is lost due to inflammation and astroglial scarring around the electrode. The inflammation and astroglial scar are thought to result from acute injury during electrode insertion as well as chronic injury caused by micromotion around the implanted electrode. To evaluate the validity of this assumption, the finite element method (FEM) was employed to analyze the strain fields around a single Michigan Si microelectrode due to simulated micromotion. Micromotion was mimicked by applying a force to the electrode, fixing the boundaries of the brain region and applying appropriate symmetry conditions to nodes lying on symmetry planes. Characteristics of the deformation fields around the electrode including maximum electrode displacement, strain fields and relative displacement between the electrode and the adjacent tissue were examined for varying degrees of physical coupling between the brain and the electrode. Our analysis demonstrates that when physical coupling between the electrode and the brain increases, the micromotion-induced strain of tissue around the electrode decreases as does the relative slip between the electrode and the brain. These results support the use of neuro-integrative coatings on electrode arrays as a means to reduce the micromotion-induced injury response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
The glial scar and central nervous system repair
Fawcett, J. W., & Asher, R. A. (1999) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00072-6 · Cited by 1,803
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Are in vivo and in situ brain tissues mechanically similar?
Gefen, A., & Margulies, S. S. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.032 · Cited by 417
Registration of 3-d intraoperative MR images of the brain using a finite-element biomechanical model
Ferrant, M., Nabavi, A., Macq, B., Jolesz, F. A., Kikinis, R., & Warfield, S. K. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974933 · Cited by 339
Constitutive model of brain tissue suitable for finite element analysis of surgical procedures
Miller, K. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00010-x · Cited by 263
A direct brain interface based on event-related potentials
Levine, S. P., Huggins, J. E., BeMent, S. L., Kushwaha, R. K., Schuh, L. A., Rohde, M. M., Passaro, E. A., Ross, D. A., Elisevich, K. V., & Smith, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847809 · Cited by 197
Kyriacou, S. K., Davatzikos, C., Zinreich, S. J., & Bryan, R. N. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.790458 · Cited by 164
Mechanical properties of tissues of the nervous system
Ommaya, A. K. (1968) · Journal of Biomechanics · doi:10.1016/0021-9290(68)90015-8 · Cited by 163
Model-driven brain shift compensation
Skrinjar, O. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00062-2 · Cited by 160
Jadin, K. D., Wong, B. L., Bae, W. C., Li, K. W., Williamson, A. K., Schumacher, B. L., Price, J. H., & Sah, R. L. (2005) · Journal of Histochemistry & Cytochemistry · doi:10.1369/jhc.4a6511.2005 · Cited by 123
Brain mechanics For neurosurgery: modeling issues
Kyriacou, S. K., Mohamed, A., Miller, K., & Neff, S. (2002) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-002-0013-0 · Cited by 110
Registration of 3D Intraoperative MR Images of the Brain Using a Finite Element Biomechanical Model
Ferrant, M., Warfield, S. K., Nabavi, A., Jolesz, F. A., & Kikinis, R. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_3 · Cited by 93
Simulation of the development of frontal head impact injury
Gilchrist, M. D., & O'Donoghue, D. (2000) · Computational Mechanics · doi:10.1007/s004660000179 · Cited by 57
Microactuated neural probes to compensate for brain micromotion
Muthuswamy, J., Gilletti, A., Jain, T., & Okandan, M. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279819 · Cited by 29
McCreery, D. B., Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02223-1 · Cited by 14
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Aravanis, A. M., Wang, L.-P., Zhang, F., Meltzer, L. A., Mogri, M. Z., Schneider, M. B., & Deisseroth, K. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s02 · Cited by 970
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Metadata
- Authors
- Lee, H., Bellamkonda, R. V., Sun, W., & Levenston, M. E.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2005-09-30
- Volume
- 2
- Issue
- 4
- Pages
- 81-89
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2068439005
- Cited by
- 281
- References
- 17
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.