Biomechanical analysis of silicon microelectrode-induced strain in the brain
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The ability to successfully interface the brain to external electrical systems is important both for fundamental understanding of our nervous system and for the development of neuroprosthetics. Silicon microelectrode arrays offer great promise in realizing this potential. However, when they are implanted into the brain, recording sensitivity is lost due to inflammation and astroglial scarring around the electrode. The inflammation and astroglial scar are thought to result from acute injury during electrode insertion as well as chronic injury caused by micromotion around the implanted electrode. To evaluate the validity of this assumption, the finite element method (FEM) was employed to analyze the strain fields around a single Michigan Si microelectrode due to simulated micromotion. Micromotion was mimicked by applying a force to the electrode, fixing the boundaries of the brain region and applying appropriate symmetry conditions to nodes lying on symmetry planes. Characteristics of the deformation fields around the electrode including maximum electrode displacement, strain fields and relative displacement between the electrode and the adjacent tissue were examined for varying degrees of physical coupling between the brain and the electrode. Our analysis demonstrates that when physical coupling between the electrode and the brain increases, the micromotion-induced strain of tissue around the electrode decreases as does the relative slip between the electrode and the brain. These results support the use of neuro-integrative coatings on electrode arrays as a means to reduce the micromotion-induced injury response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
The glial scar and central nervous system repair
Fawcett, J. W., & Asher, R. A. (1999) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00072-6 · Cited by 1,803
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Are in vivo and in situ brain tissues mechanically similar?
Gefen, A., & Margulies, S. S. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.032 · Cited by 417
Registration of 3-d intraoperative MR images of the brain using a finite-element biomechanical model
Ferrant, M., Nabavi, A., Macq, B., Jolesz, F. A., Kikinis, R., & Warfield, S. K. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974933 · Cited by 339
Constitutive model of brain tissue suitable for finite element analysis of surgical procedures
Miller, K. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00010-x · Cited by 263
A direct brain interface based on event-related potentials
Levine, S. P., Huggins, J. E., BeMent, S. L., Kushwaha, R. K., Schuh, L. A., Rohde, M. M., Passaro, E. A., Ross, D. A., Elisevich, K. V., & Smith, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847809 · Cited by 197
Kyriacou, S. K., Davatzikos, C., Zinreich, S. J., & Bryan, R. N. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.790458 · Cited by 164
Mechanical properties of tissues of the nervous system
Ommaya, A. K. (1968) · Journal of Biomechanics · doi:10.1016/0021-9290(68)90015-8 · Cited by 163
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Aravanis, A. M., Wang, L.-P., Zhang, F., Meltzer, L. A., Mogri, M. Z., Schneider, M. B., & Deisseroth, K. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s02 · Cited by 970
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Novel electrode technologies for neural recordings
Hong, G., & Lieber, C. M. (2019) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0140-6 · Cited by 695
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Self-citationWireless Optofluidic Systems for Programmable In Vivo Pharmacology and Optogenetics
Jeong, J.-W., McCall, J. G., Shin, G., Zhang, Y., Al-Hasani, R., Kim, M., Li, S., Sim, J. Y., Jang, K.-I., Shi, Y., et al. (2015) · Cell · doi:10.1016/j.cell.2015.06.058 · Cited by 498
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
“…open area of ca. 80 %, feature sizes to sub-10 micron scale, and importantly, a high flexibility with effective bending stiffness of 0.64 × 10 -15 N·m 2 ( Supplementary Information ) 4-7 orders of magnitude smaller than conventional Si 34 , carbon fiber 14 and thin polyimide 16, 35 neural probes.”
BackgroundInfluentialA Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“parameter [89, 202–204].”
BackgroundOne-step optogenetics with multifunctional flexible polymer fibers
Park, S., Guo, Y., Jia, X., Choe, H. K., Grena, B., Kang, J., Park, J., Lu, C., Canales, A., Chen, R., et al. (2017) · Nature Neuroscience · doi:10.1038/nn.4510 · Cited by 381
Bjornsson, C. S., Oh, S. J., Al-Kofahi, Y. A., Lim, Y. J., Smith, K. L., Turner, J. N., De, S., Roysam, B., Shain, W., & Kim, S. J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/002 · Cited by 330
Brain micromotion around implants in the rodent somatosensory cortex
Gilletti, A., & Muthuswamy, J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/001 · Cited by 307
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
“First, the ‘biotic’ effects include the inflammatory response, disruption of the blood– brain barrier (BBB), initiation of astrogliosis and recruitment of microglia and macrophages to the insertion site [29–36, 47–51].”
BackgroundHigh‐Density Stretchable Electrode Grids for Chronic Neural Recording
Tybrandt, K., Khodagholy, D., Dielacher, B., Stauffer, F., Renz, A. F., Buzsáki, G., & Vörös, J. (2018) · Advanced Materials · doi:10.1002/adma.201706520 · Cited by 286
Mechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274
“To further understand the impact of varying implant stiffness and structural compliance on the surrounding brain tissue we developed a 3D finite-element model to simulate interfacial strains induced by brain micromotion as described previously (16, 17).”
BackgroundMethodThermally drawn advanced functional fibers: New frontier of flexible electronics
Yan, W., Dong, C., Xiang, Y., Jiang, S., Leber, A., Loke, G., Xu, W., Hou, C., Zhou, S., Chen, M., et al. (2020) · Materials Today · doi:10.1016/j.mattod.2019.11.006 · Cited by 263
Optimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants
Ahn, D., & Ghovanloo, M. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2370794 · Cited by 246
“tion, damage, and cell death [13]–[15], at least for neuropros-”
BackgroundKozai, T. D. Y., Catt, K., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 218
“As shown in previous studies [51,52], we confirm the observation that when a small 1 mm displacement is applied to an implanted silicon electrode, the strain in the tissue is greatest at the tip of the electrode (Fig.”
Kozai, T. D. Y., Vazquez, A. L., Weaver, C. L., Kim, S.-G., & Cui, X. T. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066001 · Cited by 215
“Mechanical strain of the stiff devices tethered to the skull have been investigated and are thought to trigger the persistent chronic tissue reaction around the implant (Edell et al 1992, Biran et al 2007, Kim et al 2004, Subbaroyan et al 2005, Lee et al 2005, Gilletti and Muthuswamy 2006).”
BackgroundUltrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J. A., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 209
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Silk Hydrogels as Soft Substrates for Neural Tissue Engineering
Hopkins, A. M., De Laporte, L., Tortelli, F., Spedden, E., Staii, C., Atherton, T. J., Hubbell, J. A., & Kaplan, D. L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201300435 · Cited by 205
Donoghue, J. P., Nurmikko, A., Black, M., & Hochberg, L. R. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.127209 · Cited by 197
“Flexible microwire or thin film silicon electrodes, a new form of iNIs, can be difficult to insert and to stabilize because they have no support substrate at the cortical surface (Lee et al. 2005; Johnson et al. 2005).”
BackgroundElectroactive polymers for neural interfaces
Asplund, M., Nyberg, T., & Inganäs, O. (2010) · Polymer Chemistry · doi:10.1039/c0py00077a · Cited by 195
Electrochemical polymerization of conducting polymers in living neural tissue
Richardson-Burns, S. M., Hendricks, J. L., & Martin, D. C. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/l02 · Cited by 195
Kozai, T. D. Y., Gugel, Z., Li, X., Gilgunn, P. J., Khilwani, R., Ozdoganlar, O. B., Fedder, G. K., Weber, D. J., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.07.039 · Cited by 193
“Computer models have indicated that soft and flexible materials help minimizemechanical strain at the probe tissue interface [22,23].”
BackgroundMechanically adaptive intracortical implants improve the proximity of neuronal cell bodies
Harris, J. P., Capadona, J. R., Miller, R. H., Healy, B. C., Shanmuganathan, K., Rowan, S. J., Weder, C., & Tyler, D. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066011 · Cited by 190
“In addition to the effect of substrate stiffness, in silico modeling studies indicate that indwelling electrodes exert forces on local populations of cells (Lee et al 2005, Subbaroyan et al 2005, McConnell et al 2007).”
BackgroundKozai, T. D. Y., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.08.002 · Cited by 190
Kozai, T. D. Y., Marzullo, T. C., Hooi, F., Langhals, N. B., Majewska, A. K., Brown, E. B., & Kipke, D. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046011 · Cited by 184
“…other aspects of chronic probe design such as growth factor coatings (Azemi et al 2008), stem cell seeding (Purcell et al 2009), drug delivery (Rohatgi et al 2009), advanced probe architectures (Seymour and Kipke 2007) and flexibility (Kozai and Kipke 2009, Subbaroyan et al 2005, Lee et al 2005).”
BackgroundSpencer, K. C., Sy, J. C., Ramadi, K. B., Graybiel, A. M., Langer, R., & Cima, M. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-02107-2 · Cited by 181
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
“ORIGINAL RESEARCH ARTICLE published: 04 February 2014 doi: 10.3389/fneng.2014.00002 Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants”
BackgroundInfluentialBiointegrated and Wirelessly Powered Implantable Brain Devices: A Review
Das, R., Moradi, F., & Heidari, H. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2966920 · Cited by 172
“To add more, the compelling bending stiffness estimations of traditional and emergent neural devices [64-69] alongside that of a 20-100 μm thick slice of brain tissue [70], are plotted in Fig.”
BackgroundLarge enhancement in neurite outgrowth on a cell membrane-mimicking conducting polymer
Zhu, B., Luo, S.-C., Zhao, H., Lin, H.-A., Sekine, J., Nakao, A., Chen, C., Yamashita, Y., & Yu, H.-H. (2014) · Nature Communications · doi:10.1038/ncomms5523 · Cited by 171
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 168
A Fully-Integrated, Miniaturized (0.125 mm²) 10.5 µW Wireless Neural Sensor
Biederman, W., Yeager, D. J., Narevsky, N., Koralek, A. C., Carmena, J. M., Alon, E., & Rabaey, J. M. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2238994 · Cited by 167
“Studies indicate that reducing the amount of tissue displaced by an implant and eliminating the long-term damage caused by ‘micro-motion’ effects may mitigate a biological response [1].”
BackgroundPatterning Methods for Polymers in Cell and Tissue Engineering
Kim, H. N., Kang, D.-H., Kim, M. S., Jiao, A., Kim, D.-H., & Suh, K.-Y. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0510-y · Cited by 165
Materials for microfabricated implantable devices: a review
Scholten, K., & Meng, E. (2015) · Lab on a Chip · doi:10.1039/c5lc00809c · Cited by 161
Biocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160
“The damaged tissue assumes a state of emergency, rapidly changing its gene expression and stimulating nearby microglia and astrocytes (Lee et al., 2005; Polikov et al., 2005; Biran et al., 2007; Grill et al., 2009; McConnell et al., 2009).”
Battery-free, lightweight, injectable microsystem for in vivo wireless pharmacology and optogenetics
Zhang, Y., Castro, D. C., Han, Y., Wu, Y., Guo, H., Weng, Z., Xue, Y., Ausra, J., Wang, X., Li, R., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1909850116 · Cited by 160
Kozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136
Tien, L. W., Wu, F., Tang‐Schomer, M. D., Yoon, E., Omenetto, F. G., & Kaplan, D. L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203716 · Cited by 136
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Toward a self-deploying shape memory polymer neuronal electrode
Sharp, A. A., Panchawagh, H. V., Ortega, A., Artale, R., Richardson-Burns, S., Finch, D. S., Gall, K., Mahajan, R. L., & Restrepo, D. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/l02 · Cited by 113
Wang, J., & Dong, J. (2020) · Sensors · doi:10.3390/s20143981 · Cited by 77
Carnicer-Lombarte (2019) · doi:10.1101/829648 · Cited by 46
Fernández, E., Alfaro, A., & González-López, P. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00681 · Cited by 35
Computational assessment of neural probe and brain tissue interface under transient motion.
Polanco, M., Bawab, S., & Yoon, H. (2016) · Biosensors · doi:10.3390/bios6020027 · Cited by 36
“These property values for silicon were the same values utilized in Lee [33].”
MethodResultInfluentialHigh-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
Self-citationBiotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Metadata
- Authors
- Lee, H., Bellamkonda, R. V., Sun, W., & Levenston, M. E.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2005-09-30
- Volume
- 2
- Issue
- 4
- Pages
- 81-89
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2068439005
- Cited by
- 281
- References
- 17
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.