High frequency electrical conduction block of the pudendal nerve
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A reversible electrical block of the pudendal nerves may provide a valuable method for restoration of urinary voiding in individuals with bladder-sphincter dyssynergia. This study quantified the stimulus parameters and effectiveness of high frequency (HFAC) sinusoidal waveforms on the pudendal nerves to produce block of the external urethral sphincter (EUS). A proximal electrode on the pudendal nerve after its exit from the sciatic notch was used to apply low frequency stimuli to evoke EUS contractions. HFAC at frequencies from 1 to 30 kHz with amplitudes from 1 to 10 V were applied through a conforming tripolar nerve cuff electrode implanted distally. Sphincter responses were recorded with a catheter mounted micro-transducer. A fast onset and reversible motor block was obtained over this range of frequencies. The HFAC block showed three phases: a high onset response, often a period of repetitive firing and usually a steady state of complete or partial block. A complete EUS block was obtained in all animals. The block thresholds showed a linear relationship with frequency. HFAC pudendal nerve stimulation effectively produced a quickly reversible block of evoked urethral sphincter contractions. The HFAC pudendal block could be a valuable tool in the rehabilitation of bladder-sphincter dyssynergia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“37 μC mm−2), which is within the reported range of safety limits [25].”
BackgroundTHE USE OF ELECTRICAL DEVICES FOR THE TREATMENT OF BLADDER DYSFUNCTION: A REVIEW OF METHODS
van BALKEN, M. R., VERGUNST, H., & BEMELMANS, B. L. H. (2004) · Journal of Urology · doi:10.1097/01.ju.0000134418.21959.98 · Cited by 121 · cited 1×
“Many investigators have focused on devising blocking methods for application to the lower urinary system [9, 10].”
BackgroundParaesthesiae induced by prolonged high frequency stimulation of human cutaneous afferents
Kiernan, M. C., Hales, J. P., Gracies, J., Mogyoros, I., & Burke, D. (1997) · The Journal of Physiology · doi:10.1111/j.1469-7793.1997.461bn.x · Cited by 32
Cited by
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Foldes, E. L., Ackermann, D. M., Bhadra, N., Kilgore, K. L., & Bhadra, N. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.12.020 · Cited by 61
“…et al, 2009; Ackermann et al, 2010; Ackermann et al, in press), feline sacral roots (Boger et al, 2008; Mariano et al, 2009), sural nerves (Lahowetz et al, 2007), and pudendal nerves (Bhadra et al, 2006; Boger et al, 2008; Bruns et al, 2009), and rabbit femoral nerves (Lewandowski et al, 2009).”
BackgroundMethodSelf-citationThe design of and chronic tissue response to a composite nerve electrode with patterned stiffness
Freeberg, M. J., Stone, M. A., Triolo, R. J., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6632 · Cited by 54
Phantom limb pain: peripheral neuromodulatory and neuroprosthetic approaches to treatment
Petersen, B. A., Nanivadekar, A. C., Chandrasekaran, S., & Fisher, L. E. (2019) · Muscle & Nerve · doi:10.1002/mus.26294 · Cited by 39
Metadata
- Authors
- Bhadra, N., Bhadra, N., Kilgore, K., & Gustafson, K. J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2006-05-16
- Volume
- 3
- Issue
- 2
- Pages
- 180-187
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2083836433
- Cited by
- 117
- References
- 3
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.