Cited by 121Urinary Bladder and Prostate ResearchPelvic floor disorders treatmentsUrinary Tract Infections Management

THE USE OF ELECTRICAL DEVICES FOR THE TREATMENT OF BLADDER DYSFUNCTION: A REVIEW OF METHODS

van BALKEN, MICHAEL R., VERGUNST, HENK, BEMELMANS, BART L.H.·2004·Journal of Urology

Abstract

PURPOSE: We reviewed the literature on the application of various devices and techniques for the electrical stimulation treatment of lower urinary tract dysfunction with respect to mechanism of action and clinical outcome. MATERIALS AND METHODS: A systematic review was done in PubMed of publications on intravesical stimulation, direct bladder stimulation, stimulation of the pelvic and pudendal nerves, transcutaneous-electrical nerve stimulation, stimulation of the sacral spine and roots, and lower limb stimulation. RESULTS: It is difficult truly to compare different treatment modalities because there are hardly any randomized placebo controlled studies. Also, there is considerable variety in treatment parameters and schedules reported as well as in criteria for success. Nevertheless, it can be said that electrical neurostimulation and neuromodulation result in a 30% to 50% clinical success on an intent to treat basis. Influencing lower urinary tract innervation at the level of sacral roots seems successful in neurological and nonneurological cases. It has the advantage of pretesting possibilities to improve patient selection and treatment outcome with the obvious drawback of invasiveness. Noninvasive techniques lack screening tests, making patient selection a matter of trial and error, and when there is success patients almost always need maintenance therapy. CONCLUSIONS: Randomized clinical trials to compare different techniques and evaluate placebo effects are urgently needed, as are further studies to elucidate modes of action to improve stimulation application and therapy results. The introduction of new stimulation methods may provide treatment alternatives as well as help answer more basic questions on electrical neurostimulation and neuromodulation.

Integrity signals

Registry

Crossref · 10.1097/01.ju.0000134418.21959.98

Cites

73 of 73 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Impedance testing of the sputtered iridium oxide films also revealed Bode plots with slightly higher impedances compared the sputtered iridium oxide films reported by Cogan et al. [1] and Slavcheva et al [2], but lower compared to electrodeposited and activated iridium oxide films [3].

    “Impedance testing of the sputtered iridium oxide films also revealed Bode plots with slightly higher impedances compared the sputtered iridium oxide films reported by Cogan et al. [1] and Slavcheva et al [2], but lower compared to electrodeposited and activated iridium oxide films [3].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
van BALKEN, M. R., VERGUNST, H., & BEMELMANS, B. L. H.
Affiliations
  • From the Departments of Urology, University Medical Center Nijmegen and Canisius-Wilhelmina Hospital Nijmegen (HV), Nijmegen, The Netherlands
  • Canisius-Wilhelmina Ziekenhuis (NL)
Venue
Journal of Urology
Published
2004-09
Volume
172
Issue
3
Pages
846-851
ISSN
  • 0022-5347 (ISSN-L)
  • 1527-3792
OpenAlex
W2146282320
Cited by
121
References
73
Citations by year
2026: 3 · 2025: 1 · 2024: 5 · 2023: 4 · 2022: 5 · 2021: 4 · 2020: 1 · 2019: 5 · 2018: 6 · 2017: 7 · 2016: 4 · 2015: 5 · 2014: 5 · 2013: 4 · 2012: 8
FWCI
1.38
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of Urology (publishedVersion)
  • PubMed (publishedVersion)
  • Radboud Repository (Radboud University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Urology › Urinary Bladder and Prostate Research
  • Health Sciences › Medicine › Rheumatology › Pelvic floor disorders treatments
  • Health Sciences › Medicine › Epidemiology › Urinary Tract Infections Management
Keywords
bladder dysfunction, electrical stimulation, neurostimulation, neuromodulation, lower urinary tract dysfunction, pudendal nerve stimulation, sacral neuromodulation, transcutaneous electrical nerve stimulation, pelvic nerve stimulation, sacral roots, treatment outcomes, patient selection
MeSH terms
Animals, Urinary Bladder, Urinary Bladder, Neurogenic, Transcutaneous Electric Nerve Stimulation, Electric Stimulation Therapy, Humans, Leg, Perineum, Spinal Nerve Roots, Urination Disorders, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review