Suppression of axonal conduction by sinusoidal stimulation in rat hippocampus in vitro
The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Deep brain stimulation (DBS), also known as high frequency stimulation (HFS), is a well-established therapy for Parkinson's disease and essential tremor, and shows promise for the therapeutic control of epilepsy. However, the direct effect of DBS on neural elements close to the stimulating electrode remains an important unanswered question. Computational studies have suggested that HFS has a dual effect on neural elements inhibiting cell bodies, while exciting axons. Prior experiments have shown that sinusoidal HFS (50 Hz) can suppress synaptic and non-synaptic cellular activity in several in vitro epilepsy models, in all layers of the hippocampus. However, the effects of HFS on axons near the electrode are still unclear. In the present study, we tested the hypothesis that HFS suppresses axonal conduction in vitro. Sinusoidal HFS was applied to the alvear axon field of transverse rat hippocampal slices. The results show that HFS suppresses the alvear compound action potential (CAP) as well as the CA1 antidromic evoked potential (AEP). Complete suppression was observed as a 100% reduction in the amplitude of the evoked field potential for the duration of the stimulus. Evoked potential width and latency were not significantly affected by sinusoidal HFS. Suppression was dependent on HFS amplitude and frequency, but independent of stimulus duration and synaptic transmission. The frequency dependence of sinusoidal HFS is similar to that observed in clinical DBS, with maximal suppression between 50 and 200 Hz. HFS produced not only suppression of axonal conduction but also a correlated rise in extracellular potassium. These data provide new insights into the effects of HFS on neuronal elements, and show that HFS can block axonal activity through non-synaptic mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Stimulation of the Subthalamic Nucleus Changes the Firing Pattern of Pallidal Neurons
Hashimoto, T., Elder, C. M., Okun, M. S., Patrick, S. K., & Vitek, J. L. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-05-01916.2003 · Cited by 879 · cited 2×
“However, these studies have dealt primarily with cellular activity in either the target or efferent nuclei (Bikson et al 2001, Wu et al 2001, Hashimoto et al 2003, Lian et al 2003, Garcia et al 2005), as opposed to looking directly at axonal activity.”
Cellular Effects of Deep Brain Stimulation: Model-Based Analysis of Activation and Inhibition
McIntyre, C. C., Grill, W. M., Sherman, D. L., & Thakor, N. V. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00989.2003 · Cited by 818
Bragin, A., Engel, J., Wilson, C. L., Fried, I., & Mathern, G. W. (1999) · Epilepsia · doi:10.1111/j.1528-1157.1999.tb02065.x · Cited by 745 · cited 1×
“Another potential mechanism is stimulus-induced increases in intracellular C1− leading to development of ‘depolarizing GABA’ responses (Kaila et al 1997, Bragin et al 1999).”
Uncovering the mechanism(s) of action of deep brain stimulation: activation, inhibition, or both
McIntyre, C. C., Savasta, M., Kerkerian-Le Goff, L., & Vitek, J. L. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.12.024 · Cited by 741
Synaptic plasticity in the hippocampus: LTP and LTD
Malenka, R. C. (1994) · Cell · doi:10.1016/0092-8674(94)90517-7 · Cited by 655 · cited 1×
“…explaining the observed effects of HFS on axonal conduction is depolarization blockade, a non-synaptic, non- specific suppression of neural activity in the target structure, mediated through excess potassium in the extracellular space (Kocsis et al 1983, Malenka 1994, Benazzouz et al 1995).”
Acute and Long-Term Effects of Subthalamic Nucleus Stimulation in Parkinson's Disease
Benabid, A. L., Pollak, P., Gross, C., Hoffmann, D., Benazzouz, A., Gao, D. M., Laurent, A., Gentil, M., & Perret, J. (1994) · Stereotactic and Functional Neurosurgery · doi:10.1159/000098600 · Cited by 532 · cited 1×
“Novel neurosurgical approaches, specifically modulation of neural activity by electrical stimulation, are critical to the therapeutic control of neurological disorders including intractable epilepsy (Velasco et al 1995, 2001b, NailBoucherie et al 2002) and Parkinson’s disease (Benabid et al 1994).”
Beurrier, C., Bioulac, B., Audin, J., & Hammond, C. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1351 · Cited by 530 · cited 3×
“…stimulated tissue indicate that HFS suppresses cellular activity in vivo in humans (Dostrovsky et al 2000), in primates (Boraud et al 1996), and in rodents (Benazzouz et al 1995, 2000); and in vitro (Ghai et al 2000, Beurrier et al 2001, Bikson et al 2001, Garcia et al 2003, Lian et al 2003).”
Microstimulation-Induced Inhibition of Neuronal Firing in Human Globus Pallidus
Dostrovsky, J. O., Levy, R., Wu, J. P., Hutchison, W. D., Tasker, R. R., & Lozano, A. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.570 · Cited by 472 · cited 1×
“…done surrounding two prevailing mechanisms of high frequency stimulation (HFS), also called deep brain stimulation (DBS): excitation and/or inhibition of local and distal neural networks (Benazzouz et al 1995, Benabid et al 1998, Benazzouz and Hallet 2000, Breit et al 2000, Benabid et al 2002).”
Ammann, D. (1986) · Springer eBooks · doi:10.1007/978-3-642-52507-0 · Cited by 466
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Synchronization and desynchronization in epilepsy: controversies and hypotheses.
Jiruska, P., de Curtis, M., Jefferys, J. G. R., Schevon, C. A., Schiff, S. J., & Schindler, K. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.239590 · Cited by 678
Using a Common Average Reference to Improve Cortical Neuron Recordings From Microelectrode Arrays
Ludwig, K. A., Miriani, R. M., Langhals, N. B., Joseph, M. D., Anderson, D. J., & Kipke, D. R. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90989.2008 · Cited by 420
Zaghi, S., Acar, M., Hultgren, B., Boggio, P. S., & Fregni, F. (2010) · The Neuroscientist · doi:10.1177/1073858409336227 · Cited by 366
Developmental changes in GABAergic actions and seizure susceptibility in the rat hippocampus
Khazipov, R., Khalilov, I., Tyzio, R., Morozova, E., Ben‐Ari, Y., & Holmes, G. L. (2004) · European Journal of Neuroscience · doi:10.1111/j.0953-816x.2003.03152.x · Cited by 314
Single-trial EEG classification of motor imagery using deep convolutional neural networks
Tang, Z., Li, C., & Sun, S. (2017) · Optik · doi:10.1016/j.ijleo.2016.10.117 · Cited by 299
Thread as a Versatile Material for Low-Cost Microfluidic Diagnostics
Li, X., Tian, J., & Shen, W. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am9006148 · Cited by 275
A lower limb exoskeleton control system based on steady state visual evoked potentials
Kwak, N.-S., Müller, K.-R., & Lee, S.-W. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056009 · Cited by 221
Automated model selection in covariance estimation and spatial whitening of MEG and EEG signals
Engemann, D. A., & Gramfort, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.040 · Cited by 203
A Riemannian Modification of Artifact Subspace Reconstruction for EEG Artifact Handling
Blum, S., Jacobsen, N. S. J., Bleichner, M. G., & Debener, S. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00141 · Cited by 186
High frequency stimulation can block axonal conduction
Jensen, A. L., & Durand, D. M. (2009) · Experimental Neurology · doi:10.1016/j.expneurol.2009.07.023 · Cited by 172
“Additionally, pharmacological blockade of these components does not influence the presence nor measurement of the alvear CAP (Jensen and Durand 2007b).”
BackgroundMethodResultSelf-citationLuo, T.-J., Zhou, C.-L., & Chao, F. (2018) · BMC Bioinformatics · doi:10.1186/s12859-018-2365-1 · Cited by 161
Deep Learning–Based Scene Simplification for Bionic Vision
Han, N., Srivastava, S., Xu, A., Klein, D., & Beyeler, M. (2021) · Augmented Humans Conference 2021 · doi:10.1145/3458709.3458982 · Cited by 45
Optical control of neuronal excitation and inhibition using a single opsin protein, ChR2
Liske, H., Qian, X., Anikeeva, P., Deisseroth, K., & Delp, S. (2013) · Scientific Reports · doi:10.1038/srep03110 · Cited by 42
Metadata
- Authors
- Jensen, A. L., & Durand, D. M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2007-01-24
- Volume
- 4
- Issue
- 2
- Pages
- 1-16
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2062565038
- Cited by
- 180
- References
- 65
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.