Visual modifications on the P300 speller BCI paradigm
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
The best known P300 speller brain-computer interface (BCI) paradigm is the Farwell and Donchin paradigm. In this paper, various changes to the visual aspects of this protocol are explored as well as their effects on classification. Changes to the dimensions of the symbols, the distance between the symbols and the colours used were tested. The purpose of the present work was not to achieve the highest possible accuracy results, but to ascertain whether these simple modifications to the visual protocol will provide classification differences between them and what these differences will be. Eight subjects were used, with each subject carrying out a total of six different experiments. In each experiment, the user spelt a total of 39 characters. Two types of classifiers were trained and tested to determine whether the results were classifier dependant. These were a support vector machine (SVM) with a radial basis function (RBF) kernel and Fisher's linear discriminant (FLD). The single-trial classification results and multiple-trial classification results were recorded and compared. Although no visual protocol was the best for all subjects, the best performances, across both classifiers, were obtained with the white background (WB) visual protocol. The worst performance was obtained with the small symbol size (SSS) visual protocol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“In this BCI protocol, the user is able to interact with the interface by paying attention to chosen rare target stimuli during a random sequence of target and non-target stimuli (oddball paradigm) [1–3].”
MethodUpdating P300: An integrative theory of P3a and P3b
Polich, J. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.019 · Cited by 7,919
Chiang, L. H., Russell, E. L., & Braatz, R. D. (2001) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0347-9_3 · Cited by 5,003
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665 · cited 8×
“Its linearity is often cited as its main disadvantage [9, 10].”
BackgroundMethodInfluentialThe mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222 · cited 1×
“Therefore, many state of the art methods such as discreet wavelet transforms and recursive channel elimination have been ignored in favour of simplicity and comparability [8, 11, 14].”
The BCI competition III: validating alternative approaches to actual BCI problems
Blankertz, B., Muller, K.-R., Krusienski, D. J., Schalk, G., Wolpaw, J. R., Schlogl, A., Pfurtscheller, G., Millan, J. R., Schroder, M., & Birbaumer, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875642 · Cited by 927 · cited 1×
“Due to this fact and due to inherent physiological limitations, the transfer rate of such systems is very slow [6, 7].”
BackgroundBashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907 · cited 3×
“Its linearity is often cited as its main disadvantage [9, 10].”
BackgroundMethodA comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“Performance decreases when matrices with smaller symbols are used [132], and it is enhanced when a green and blue chromatic flicker matrix is used, rather than a gray and black one [133,134].”
BackgroundSingle-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570
“Salvaris and Sepulveda (2009) compared changes to the background/foreground colors, item size, and distances between items.”
BackgroundP300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 359
Flashing characters with famous faces improves ERP-based brain–computer interface performance
Kaufmann, T., Schulz, S. M., Grünzinger, C., & Kübler, A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056016 · Cited by 300
Xu, M., Xiao, X., Wang, Y., Qi, H., Jung, T.-P., & Ming, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2799661 · Cited by 227
“However, the BCI’s performance would be greatly compromised once the stimulus area was reduced [30], [31].”
BackgroundXu, M., Han, J., Wang, Y., Jung, T.-P., & Ming, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2975614 · Cited by 165
A comparison study of two P300 speller paradigms for brain–computer interface
Pan, J., Li, Y., Gu, Z., & Yu, Z. (2013) · Cognitive Neurodynamics · doi:10.1007/s11571-013-9253-1 · Cited by 46
“…individual parameters of the paradigm have been studied and optimized, which include matrix size (Allison and Pineda 2003), stimulus interval (Sellers et al. 2006), stimulus intensity and so on Takano et al. (2009), Allison and Pineda (2006), Salvaris and Sepulveda (2009), McFarland et al. (2011).”
BackgroundReichert, C., Tellez Ceja, I. F., Sweeney-Reed, C. M., Heinze, H.-J., Hinrichs, H., & Dürschmid, S. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.591777 · Cited by 23
Guo, M., Jin, J., Jiao, Y., Wang, X., & Cichockia, A. (2019) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2019.00024 · Cited by 18
“Consequently, white backgroundwas superior to the black one in terms of performance (Salvaris and Sepulveda, 2009).”
Background
Metadata
- Authors
- Salvaris, M., & Sepulveda, F.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2009-07-15
- Volume
- 6
- Issue
- 4
- Pages
- 046011
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2056945694
- Cited by
- 197
- References
- 25
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.