Electrocorticographic amplitude predicts finger positions during slow grasping motions of the hand
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Four human subjects undergoing subdural electrocorticography for epilepsy surgery engaged in a range of finger and hand movements. We observed that the amplitudes of the low-pass filtered electrocorticogram (ECoG), also known as the local motor potential (LMP), over specific peri-Rolandic electrodes were correlated (p < 0.001) with the position of individual fingers as the subjects engaged in slow and deliberate grasping motions. A generalized linear model (GLM) of the LMP amplitudes from those electrodes yielded predictions for positions of the fingers that had a strong congruence with the actual finger positions (correlation coefficient, r; median = 0.51, maximum = 0.91), during displacements of up to 10 cm at the fingertips. For all the subjects, decoding filters trained on data from any given session were remarkably robust in their prediction performance across multiple sessions and days, and were invariant with respect to changes in wrist angle, elbow flexion and hand placement across these sessions (median r = 0.52, maximum r = 0.86). Furthermore, a reasonable prediction accuracy for grasp aperture was achievable with as few as three electrodes in all subjects (median r = 0.49; maximum r = 0.90). These results provide further evidence for the feasibility of robust and practical ECoG-based control of finger movements in upper extremity prosthetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 8×
“Most previously reported BMIs based on ECoG or EEG signals utilize the modulation of sensorimotor rhythms such as the mu, beta and gamma rhythms [10–18].”
ResultInfluentialControl of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Pfurtscheller, G., Stancák, A., & Neuper, C. (1996) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(96)00066-9 · Cited by 1,205
Patients with ALS can use sensorimotor rhythms to operate a brain-computer interface
Kübler, A., Nijboer, F., Mellinger, J., Vaughan, T. M., Pawelzik, H., Schalk, G., McFarland, D. J., Birbaumer, N., & Wolpaw, J. R. (2005) · Neurology · doi:10.1212/01.wnl.0000158616.43002.6d · Cited by 539
Brain oscillations control hand orthosis in a tetraplegic
Pfurtscheller, G., Guger, C., Müller, G., Krausz, G., & Neuper, C. (2000) · Neuroscience Letters · doi:10.1016/s0304-3940(00)01471-3 · Cited by 472
Emulation of computer mouse control with a noninvasive brain–computer interface
McFarland, D. J., Krusienski, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/001 · Cited by 202
Cited by
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Brain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
An Electrocorticographic Brain Interface in an Individual with Tetraplegia
Wang, W., Collinger, J. L., Degenhart, A. D., Tyler-Kabara, E. C., Schwartz, A. B., Moran, D. W., Weber, D. J., Wodlinger, B., Vinjamuri, R. K., Ashmore, R. C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055344 · Cited by 402
Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350
Upper limb movements can be decoded from the time-domain of low-frequency EEG
Ofner, P., Schwarz, A., Pereira, J., & Müller-Putz, G. R. (2017) · PLOS ONE · doi:10.1371/journal.pone.0182578 · Cited by 253
Metadata
- Authors
- Acharya, S., Fifer, M. S., Benz, H. L., Crone, N. E., & Thakor, N. V.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2010-05-20
- Volume
- 7
- Issue
- 4
- Pages
- 046002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2092533627
- Cited by
- 150
- References
- 8
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrocorticographic amplitude predicts finger positions during slow grasping motions of the hand. https://app.cochat.ai/papers/10.1088/1741-2560/7/4/046002
- The paper
- Acharya, S., Fifer, M. S., Benz, H. L., Crone, N. E., & Thakor, N. V. (2010). Electrocorticographic amplitude predicts finger positions during slow grasping motions of the hand. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/7/4/046002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.